OUTPUT WIRING
To install the output wiring to the camera, dome, or positioning system, refer to Figure 4 and do the following:
1.Refer to Table A and determine the output connection needed for your camera, dome, or positioning system. Refer to Figure 4, for the proper connector strip connections.
2.Attach one output wire to either the Tap A (24 VAC), Tap B (26 VAC), or Tap C (28 VAC) connections on the Secondary Output Tap’s connector strip and attach the second wire to the COM connection on the same strip. Be sure that you have the proper wiring size and distances installed if you plan to change connections later.
3.Close the lid to the
FUSE HOLDER
INPUT TERMINALS
GROUND STUD
SPARE FUSES
120V- F 1.6A H |
240V- F 0.5A H |
OUTPUT TERMINALS |
Figure 4. Wiring Connector Diagram
6 |