Sharp AY-X09NCJ, AY-X28NCJ Installation Site Instructions, Installation Site of Indoor Unit

Page 13

Notices of Installation

CAUTION

(1)Before installation, please contact your local authorised installer. This unit must be installed by an authorised installer according to local or government regulations and in compliance with this manual to avoid a malfunction.

(2)When relocating this unit, please contact your local authorised installer.

(3)Warning: Before obtaining access to terminals, all supply circuits must be disconnected at the circuit breaker.

(4)If the power cord is damaged, it must be replaced by the installer or authorised service technician in order to avoid a hazard.

(5)The appliance must be positioned so that the plug is accessible (AYX09 & AYX12 Only).

(6)The temperature of refrigerant circuit will be high, please keep the interconnection cable away from the copper tube.

(7)This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.

Children should be supervised to ensure that they do not play with the appliance.

Installation Site Instructions

Proper installation site is vital for correct and efficient operation of the unit. Avoid the following sites where:

Strong heat sources, vapours, flammable gas or volatile liquids are emitted.

High-frequency electro-magnetic waves are generated by radio equipment, welders and medical equipment.

Salt-laden air prevails (such as close to coastal areas).

The air is contaminated with industrial vapours and oils.

Corrosion on neighbouring materials exists.

Installation Site of Indoor Unit

The air inlet and outlet should be away from any obstructions. Ensure the air can be blown through the whole room.

Select a site where the condensing water can be easily drained out, and where it is easily connected for outdoor unit.

Select a place where is it out of reach of children.

Select the place where the wall is strong enough to withstand the full weight and vibration of the unit.

Be sure to leave enough space to allow access for routine maintenance. The installation site should be 250cm or more above the floor.

Select a place about 1m or more away from TV set or any electric appliance.

Select a place where the filter can be easily taken out.

Make sure that the indoor unit is installed in accordance with the installation instructions.

Installation Site of Outdoor Unit

Select a site where noise and outflow air emitted by unit will not annoy neighbours.

Select a site where there is sufficient ventilation.

Select a site where there is no obstruction blocking the inlet and outlet.

the site should be able to withstand the full weight and vibration of the unit.

Select a dry place, but do not expose the unit to direct sunlight or strong wind.

Make sure that the outdoor unit is installed in accordance with the installation instructions, and access is convenient for maintenance and repair.

Ensure that the height difference between indoor and outdoor units for the 09K is within 15M, the 12K,18K,24K & 28K is within 10m. Ensure the length of the connection tubing for 09K does not exceed 10m; for 12K does not exceed 20m, for 18K, 24K, 28K does not exceed 25m.

Select a place where it is out of reach of children.

Select a place which will not block pedestrian passage.

13

Image 13
Contents Split Type Inverter Room Air Conditioner Contents Please read the following carefully before operating Name of parts Sleep button ON/OFF buttonFAN button Operation of wireless remote control con’t Feel button Temp buttonIntroduction of Special Function Temp Range Cool Mode Heat Mode SleepEmergency Operation Changing batteries and noticesCleaning the Front Panel Care and CleaningCleaning the Air Filter every 3 months Phenomenon Troubleshooting TroubleshootingPlease Note Operation Tips Installation Site of Indoor Unit Installation Site InstructionsInstallation Site of Outdoor Unit Earthing Requirements Safety Precautions for Electric AppliancesInstallation Drawing Installation of Drain Hose Installation of Indoor UnitDrill Piping Hole Connecting Indoor and Outdoor Electric Wires Installation of Indoor Unit con’tInstallation of Connection Pipe Electric Wiring Installation of Outdoor UnitAir Purging and Leakage Test Outdoor Condensate Drainage only for Heat pump unitCheck after Installation Check after Installation and Operation TestOperation Test Cooling Heating SpecificationsAC12RNSYS AC18RNSYS AC24RNSYS AC28RNSYS Page Page Page N 003 039

AE-X12NCJ, AE-X28NCJ, AE-X09NCJ, AE-X18NCJ, AE-X24NCJ specifications

The Sharp AY-X12NCJ, AE-X18NCJ, AY-X28NCJ, and AY-X18NCJ, AE-X28NCJ models are remarkable air conditioning units designed to provide efficient cooling and heating solutions for various spaces. These units combine advanced technology and user-friendly features that cater to the needs of residential and commercial environments.

One of the standout features of these models is the incorporation of Plasmacluster Ion Technology, which helps to purify the air by generating positive and negative ions. This technology effectively eliminates bacteria, viruses, and allergens from the air, promoting a healthier indoor environment. The air purification feature is particularly beneficial for individuals with allergies or respiratory issues, as it continuously improves air quality.

Additionally, the Sharp AY-X and AE-X series is equipped with inverter technology, allowing for variable speed operation. This technology ensures that the compressor runs at different speeds tailored to the desired temperature setting, leading to significant energy savings. Inverter systems not only enhance energy efficiency but also provide a quieter operation, creating a more comfortable atmosphere without the disruptive noise often associated with traditional air conditioners.

Another notable characteristic is the modification of the cooling and heating modes. These units come with several modes that can be adjusted based on user preferences, such as turbo cooling for rapid temperature adjustment or sleep mode that gradually adjusts the temperature for optimal comfort during the night.

Moreover, the Sharp AY-X and AE-X series includes smart features such as remote control capabilities, allowing users to set and modify settings from a distance. This convenience is especially advantageous for busy individuals who want to come home to a pre-cooled or heated space without the hassle of manual adjustments.

Energy efficiency is further enhanced by the use of R32 refrigerant, which has a lower global warming potential compared to traditional refrigerants. This environmentally friendly refrigerant not only contributes to reducing energy consumption but also aligns with global initiatives to promote sustainability.

Overall, the Sharp AY-X12NCJ, AE-X18NCJ, AY-X28NCJ, AY-X18NCJ, and AE-X28NCJ models are designed for those seeking reliable, efficient, and advanced air conditioning solutions. With features that promote air quality, energy efficiency, and user convenience, these units stand out in the competitive market of HVAC systems.