Sharp AE-X24NCJ, AY-X28NCJ, AY-X24NCJ, AY-X12NCJ, AY-X09NCJ ON/OFF button, Sleep button, FAN button

Page 5

Operation of wireless remote control

Indoor Front Panel Lights : RED power light should be on while power is applied. If blinking please call for service. ORANGE = Heat, BLUE = Cool.

Note: Be sure that there are no obstructions between indoor receiver and remote control. Take care not to drop or throw the remote. Do not spill any liquid on the remote control. Do not leave remote control directly in sunlight or hot environments.

ON/OFF button

Press this button to turn unit on and off. Sleep function will be cancelled if unit is turned off.

MODE button

Press this button, Auto, Cool, Dry, Fan, Heat mode can be selected in the following sequence. Auto mode is default when first turned on. Under Auto mode, the temperature will not be displayed on the remote but there is a temperature display on the indoor unit; Under Heat mode, the HEAT initial value is 28°C (82°F); Under other modes, the initial value is 25°C (77°F).

(Only for cooling and heating unit as for cooling only unit, it won’t have any action when it receives the signal of heating operation.)

SLEEP button

Press this button to turn Sleep mode on or off. Sleep mode “off” is default when unit is first turned on. Sleep function is cancelled when unit is switched off. Sleep mode duration can be adjusted. Sleep mode is not available under the Fan and Auto modes.

FAN button

Press this button to select between Auto, Low, Middle and High speed fan settings. Auto fan speed is default when unit switched on.

Under DRY mode, Low fan speed only can be set up.

CLOCK button

Press this button to set clock function. The clock symbol will blink and display. Within 5 seconds the time can be adjusted by pressing or button. Hold down button continuously for rapid time change. Press clock button again to complete time setting.

5

Image 5
Contents Split Type Inverter Room Air Conditioner Contents Please read the following carefully before operating Name of parts FAN button ON/OFF buttonSleep button Operation of wireless remote control con’t Feel button Temp buttonIntroduction of Special Function Temp Range Cool Mode Heat Mode SleepEmergency Operation Changing batteries and noticesCleaning the Air Filter every 3 months Care and CleaningCleaning the Front Panel Please Note TroubleshootingPhenomenon Troubleshooting Operation Tips Installation Site of Outdoor Unit Installation Site InstructionsInstallation Site of Indoor Unit Earthing Requirements Safety Precautions for Electric AppliancesInstallation Drawing Drill Piping Hole Installation of Indoor UnitInstallation of Drain Hose Installation of Connection Pipe Installation of Indoor Unit con’tConnecting Indoor and Outdoor Electric Wires Electric Wiring Installation of Outdoor UnitAir Purging and Leakage Test Outdoor Condensate Drainage only for Heat pump unitOperation Test Check after Installation and Operation TestCheck after Installation Cooling Heating SpecificationsAC12RNSYS AC18RNSYS AC24RNSYS AC28RNSYS Page Page Page N 003 039

AE-X12NCJ, AE-X28NCJ, AE-X09NCJ, AE-X18NCJ, AE-X24NCJ specifications

The Sharp AY-X12NCJ, AE-X18NCJ, AY-X28NCJ, and AY-X18NCJ, AE-X28NCJ models are remarkable air conditioning units designed to provide efficient cooling and heating solutions for various spaces. These units combine advanced technology and user-friendly features that cater to the needs of residential and commercial environments.

One of the standout features of these models is the incorporation of Plasmacluster Ion Technology, which helps to purify the air by generating positive and negative ions. This technology effectively eliminates bacteria, viruses, and allergens from the air, promoting a healthier indoor environment. The air purification feature is particularly beneficial for individuals with allergies or respiratory issues, as it continuously improves air quality.

Additionally, the Sharp AY-X and AE-X series is equipped with inverter technology, allowing for variable speed operation. This technology ensures that the compressor runs at different speeds tailored to the desired temperature setting, leading to significant energy savings. Inverter systems not only enhance energy efficiency but also provide a quieter operation, creating a more comfortable atmosphere without the disruptive noise often associated with traditional air conditioners.

Another notable characteristic is the modification of the cooling and heating modes. These units come with several modes that can be adjusted based on user preferences, such as turbo cooling for rapid temperature adjustment or sleep mode that gradually adjusts the temperature for optimal comfort during the night.

Moreover, the Sharp AY-X and AE-X series includes smart features such as remote control capabilities, allowing users to set and modify settings from a distance. This convenience is especially advantageous for busy individuals who want to come home to a pre-cooled or heated space without the hassle of manual adjustments.

Energy efficiency is further enhanced by the use of R32 refrigerant, which has a lower global warming potential compared to traditional refrigerants. This environmentally friendly refrigerant not only contributes to reducing energy consumption but also aligns with global initiatives to promote sustainability.

Overall, the Sharp AY-X12NCJ, AE-X18NCJ, AY-X28NCJ, AY-X18NCJ, and AE-X28NCJ models are designed for those seeking reliable, efficient, and advanced air conditioning solutions. With features that promote air quality, energy efficiency, and user convenience, these units stand out in the competitive market of HVAC systems.