HP Video Game 00974-90002 manual Minimum/Maximum, Action Main Display Secondary Display

Page 10

Operation

 

 

Minimum/Maximum 1

 

 

Press

Action

Main Display

Secondary Display 2

 

Begin recording of min, max, and avg

3

Elapsed time

 

values

Each measured value

 

 

 

 

Display recorded maximum

Maximum measurement

Time of Maximum

 

Display recorded minimum

Minimum measurement

Time of Minimum

 

Display recorded average

Calculated average

Elapsed time

 

Display last recorded measurement

Latest measurement

Elapsed time

 

Pause recording of minimum and

Last measured value

Total elapsed time

 

maximum values

 

 

 

 

Resume recording of minimum and

Each measured value

Elapsed time

 

maximum values

 

 

 

 

Press and hold 1 second to cancel

-

-

1

Automatic power off is disabled when Min/Max is selected.

 

2

3

Time is recorded and displayed in minutes and seconds up to 99’ 59". After 99’ 59" time is recorded and displayed in minutes up to the maximum recording time of 1999 minutes. Recording will stop at the maximum time.

Average is computed from all readings during elapsed time.

Average

Press

Action

Main Display

Secondary Display

 

Makes the displayed measurement the

Average value of last eight

Range

 

average of the last eight measurements

measurements

 

 

 

Disables the averaging of measurements

Each measurement

Range

1-10

Image 10
Contents HP 974A Multimeter User’s Guide Page Table of Contents HP 974A MultimeterSafety Summary Safety SymbolsSafety Summary Maximum Overvoltage Limitations AC and DC Voltage FunctionsProbes and Test Leads Function Maximum Operating InputOperation Terminals, Shutter, & Test LeadsFunction Switch Switch Display PositionFunction Keys Press Action Main Display Secondary DisplayMinimum/Maximum Action Main Display Secondary DisplayHold/Auto-Hold Function Relative Min/Max Function Keys and Function Switch MatrixData Hold Auto-Hold Range Percent Display Power onAuto Power Off AudioCalibration Procedure Calibration and AdjustmentRequired Test Equipment Battery Replacement MaintenanceFuse Replacement Replaceable Parts/Accessories TroubleshootingCleaning Problem Possible Cause Suggested ActionGeneral SpecificationsRange Resolution Accuracy Input Resistance DC VoltageAC + DC Voltage rms responding, computed from acV, dcV DC Current, AC Current 40 Hz to 1 kHz, 5% to 100% of rangeDiode ResistanceContinuity Frequency AC CoupledTemperature 5 kΩ @ 25C Thermistor probe Adjustments Calibration Table Step Function Range Input Signal AdjustmentLimit Counts Step Function Range Input Signal Replaceable Parts/Accessories Call out Description HP Part NumberDisassembly Manufacturer’s Address Conforms to the following Product SpecificationsManufacturer’s Name Declares, that the productsWhat is Covered Warranty/ServiceWhat is Not Covered