HP Video Game 00974-90002 Replaceable Parts/Accessories, Call out Description HP Part Number

Page 24

Replaceable Parts/Accessories

Refer to the disassembly diagram on page 6-5.

Call out

Description

HP Part Number

 

 

 

F1

Fuse, 500 mA, 250 V fast blow Littlefuse 216-500

2110-0940

DO NOT SUBSTITUTE

 

 

 

 

 

F2

Fuse, 15 A, 600 V fast blow Littlefuse KLK15

2110-0941

DO NOT SUBSTITUTE

 

 

 

 

 

MP1

Top case assembly

00974-64401

 

 

 

MP2

Dust/moisture seal

00971-64403

 

 

 

MP3

Bottom case assembly (includes stand)

00974-64402

 

 

 

 

Rubber Boot

00971-86001

 

 

 

 

Replacement Test Leads, 2 pair

E2305A

 

 

 

 

Temperature probe, 5 KΩ Thermistor

E2308A

 

 

 

 

Surface temperature sensor,

 

 

Thermistor ±0.1°C

40653B

 

12" lead, requires dual banana plug

 

 

 

 

 

Soft Case

E2304A

 

(fits meter with rubber boot)

 

 

 

 

 

 

 

 

Operator protection from electric shock hazard is provided by a double insulated enclosure. Refer to the Safety Summary for maximum voltage specifications. When servicing, use only specified replacement parts.

6-4

Image 24
Contents HP 974A Multimeter User’s Guide Page Table of Contents HP 974A MultimeterSafety Summary Safety SymbolsSafety Summary Maximum Overvoltage Limitations AC and DC Voltage FunctionsProbes and Test Leads Function Maximum Operating InputOperation Terminals, Shutter, & Test LeadsFunction Switch Switch Display PositionFunction Keys Press Action Main Display Secondary DisplayMinimum/Maximum Action Main Display Secondary DisplayHold/Auto-Hold Function Keys and Function Switch Matrix Function Relative Min/MaxData Hold Auto-Hold Range Percent Power on Auto Power OffDisplay AudioCalibration and Adjustment Calibration ProcedureRequired Test Equipment Maintenance Battery ReplacementFuse Replacement Troubleshooting CleaningReplaceable Parts/Accessories Problem Possible Cause Suggested ActionSpecifications Range Resolution Accuracy Input ResistanceGeneral DC VoltageAC + DC Voltage rms responding, computed from acV, dcV DC Current, AC Current 40 Hz to 1 kHz, 5% to 100% of rangeResistance ContinuityDiode Frequency AC CoupledTemperature 5 kΩ @ 25C Thermistor probe Adjustments Step Function Range Input Signal Adjustment Calibration TableLimit Counts Step Function Range Input Signal Replaceable Parts/Accessories Call out Description HP Part NumberDisassembly Conforms to the following Product Specifications Manufacturer’s NameManufacturer’s Address Declares, that the productsWarranty/Service What is CoveredWhat is Not Covered