Thermo Products Models from 8 kW to 24 kW : 240 Volts ( single phase ) DIMENSION/ Dimensional

Page 3

DESSIN D'ATELIER / GENERAL DIMENSIONS COMBOMAX XX-XX THERMO 2000 inc.

Figure 2

7

HI

F 1

4

G

Legeng/Légende:

1) Boiler Water Supply Connection / Alimentation du chauffage (1" npt F)

2) Boiler Water Return/

Retour du chauffage (1" npt F)

3) Domestic Water inlet /

Entrée eau domestique (3/4" Sweat F)

4) Domestic Water outlet/

Sortie eau domestique (3/4" Sweat F)

5) Safety relief valve/

Soupape de sûreté (3/4" npt M.)

6) Temperature and pressure Gage/

Indicateur de Température et pression (1/2'' npt. M)

7) Drain Valve/

Valve de drainage (3/4'' npt F)

8) Power supply wiring/ Alimentation électrique

9) Pilot Lights/ Lampe témoin

10) Electrical Compartments/ Compartiment électrique

11) Circulator wiring/ Alimentation pompe

12) Thermostat wiring/ Connection thermostat

13) Air vent/ Purgeur d'air

14) Valve 3 voies/

3 ways valve

15) Valve thermostatique/ Thermostatic mixing valve

16) Adjustable leg/ Patte de support

14

15

3

6

 

13

5

8

 

 

2

11

9

12

10

A

B

C E

 

 

 

D

 

 

16

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DIMENSION/ DIMENSIONAL

 

 

 

 

 

 

 

 

 

 

 

Modèle/

A

B

C

 

D

 

E

F

G

H

I

Model

in.

in.

in.

 

in.

 

in.

in.

in.

in.

degrés/degree

COMBOMAX 23-XX

49

3/16

42 1/4

7 1/4

 

4

 

1

18

10 1/2

8

75

COMBOMAX 34-XX

65

1/2

59

7 1/4

 

4

 

1

18

10 1/2

8

75

COMBOMAX 44-XX

57

3/4

49 1/2

9 1/2

5

3/4

 

1

22

12 1/2

8

60

COMBOMAX 64-XX

65

1/2

58 1/2

9 1/2

6

1/2

 

1

24

13 1/2

8

60

Page 3

Image 3
Contents Combomax Domestic hot water production capacity in US gallons Technical specificationsBoiler specifications 240 Vac single phase Boiler and connection dimensionsDIMENSION/ Dimensional Corrosive Atmosphere Local Installation RegulationsChecklist IntroductionInstallation Makeup valve Flow-check valvePressure relief valve Operating pressure control expansion tankConnecting the domestic hot water piping Domestic HOT Water CircuitExpansion tank on the cold water supply line Boiler Wiring Circulator WiringPrioritizing Terminal Post BI-ENERGY Setup Filling the Heating Coil Adjusting the AquastatsOperation Filling the TankDomestic HOT Water Startup Startup ProcedureAdjusting the Mixing Valve Maintenance General Safety Precautions Combomax Schéma dinstallation général/ General installation Système primaire/secondaire TH1 TH2 EL1 EL2 TH1 EL1 TH2 EL2 24 Vac Bi-énergie avec Valve 3 Voies/ Dual Energy with 3-way valve Diagramme électrique/ Wiri ng diagram Thermo 2000 inc Panneau de contrôlel Control pannel Combomax TM Limited Warranty