Thermo Products Models from 8 kW to 24 kW : 240 Volts ( single phase ) TH1 TH2 EL1 EL2

Page 18

L1

Figure 5

G

TH1

C1

TH2

EL1

EL2

Diagramme électrique/ Wiri ng diagram

 

 

COMBOMAX 240V

 

 

Modèle/Model 6 - 10 KW

 

 

L2

 

N

F

R5

 

HL

Voir/see note 2

C1

 

 

R4

C

C

C1

 

 

 

120 V

 

TH

C

HL

Légende/ Legend

AquastatR

Élément chauffant/ Heating element

Contacteur de puissance Power relay

Haute limite

Hi-Limit

Thermostat

 

 

 

 

24 V

 

 

 

 

TH5

 

 

 

R1

Relais

 

 

 

 

 

 

 

 

 

 

 

Relay

 

 

 

 

 

R2

Lampe témoin

 

 

 

 

 

R3

Pilot light

 

 

 

 

 

Fusible

R3

 

 

R3

 

Fuse

 

T

T

 

 

 

Cablage en usine/

 

 

 

R4

 

 

 

Chauffage/ Heating

Factory wiring

 

 

Brun/ Brown

 

Cablage par l'installateur/

 

 

B

 

 

 

 

 

 

 

Wiring by others

 

 

Noir / Black

AB

Valve 3 voies /

 

 

 

 

 

Circulateur/

 

 

R1 BlueBleu /

 

Voir/see note 2

R6

 

3-way valve

 

Circulator

A

 

 

 

 

 

Recirculation

 

 

Page 18

Note 1: Bloc terminal (24VAC) pour une installation avec le

controleur bi-énergie Thermo 2000 modèle: "CBE-EM"/ Terminal block (24 VAC) for aninstallation with Thermo 2000 dual

energy controller model: "CBE-EM"

Note 2: Couper le cavalier lorsque vous utilisez le controleur

bi-énergie Thermo2000 modèle: "CBE-EM"/

Cut open this jumper when using Thermo 2000 dual energy controller model: "CBE-EM"

Contact sec/

R2

K

Dry contact

Voir/see note 1 R5

K

E2

R6

V2

 

Image 18
Contents Combomax Boiler and connection dimensions Technical specificationsBoiler specifications 240 Vac single phase Domestic hot water production capacity in US gallonsDIMENSION/ Dimensional Introduction Local Installation RegulationsChecklist Corrosive AtmosphereInstallation Operating pressure control expansion tank Flow-check valvePressure relief valve Makeup valveConnecting the domestic hot water piping Domestic HOT Water CircuitExpansion tank on the cold water supply line Boiler Wiring Circulator WiringPrioritizing Terminal Post BI-ENERGY Setup Filling the Tank Adjusting the AquastatsOperation Filling the Heating CoilStartup Procedure Domestic HOT Water StartupAdjusting the Mixing Valve Maintenance General Safety Precautions Combomax Schéma dinstallation général/ General installation Système primaire/secondaire TH1 TH2 EL1 EL2 TH1 EL1 TH2 EL2 24 Vac Bi-énergie avec Valve 3 Voies/ Dual Energy with 3-way valve Diagramme électrique/ Wiri ng diagram Thermo 2000 inc Panneau de contrôlel Control pannel Combomax TM Limited Warranty