Table 8 Switch data window entries (Continued)
Entry | Description |
|
|
Status |
|
|
|
Operational State | Switch operational state: Online, Offline, Diagnostic, Down |
|
|
Administrative State | Current switch administrative state |
|
|
Configured Admin State | Switch administrative state that is stored in the switch configuration |
|
|
Beacon Status | Beacon status. Switch LEDs are blinking (On) or not (off). |
|
|
Reason for Status | Additional status information |
|
|
Temperature | Internal switch temperature °C |
|
|
Fan 1 Status | Not applicable. |
|
|
Fan 2 Status | Not applicable. |
|
|
Fan 3 Status | Not applicable. |
|
|
Power Supply 1 Status | Switch power status |
|
|
Power Supply 2 Status | Not applicable. |
|
|
Temp Failure Port Shutdown | Port shutdown status when failure temperature is exceeded. |
|
|
Warning Temperature | Temperature threshold (65° Celsius) above which a warning |
| condition alarm is generated. |
|
|
Failure Temperature | Temperature threshold (70° Celsius) above which a failure condition |
| alarm is generated. |
|
|
Diag Status | Diagnostic status |
|
|
Diag Fault Code | Not applicable. |
|
|
Test Status | Not applicable. |
|
|
Test Fault Code | Not applicable. |
|
|
Network |
|
|
|
IP Address | Internet Protocol address |
|
|
Subnet Mask | Mask that determines the IP address subnet |
|
|
Gateway | Gateway address |
|
|
SNMP Enabled | SNMP enabled or disabled. |
|
|
Broadcast Support | Broadcast support status. Broadcast support is enabled (default) or |
| disabled. |
|
|
NTP Client Enabled | Enabled or disabled. Allows for switches to synchronize their time to |
| a centralized server. |
|
|
NTP Server Address | The IP address of the centralized NTP server. Ethernet connection to |
| NTP server is required. |
|
|
Use Front Port | Not applicable. |
|
|