SNMP requests can be received in either 3.0 or 3.1 of the Fibre Alliance (FA) MIB, and the switch responds in the same version. The switch can also be configured to use a specific version for traps generated by the switch.
Zoning limitations
With firmware 06.00.00 and later, you have the ability to configure large zone sets, including up to 1024 zones and 1024 end ports in a single zone set. Table 3 shows the supported limits for the edge switches and directors.
Table 3 Zoning parameters supported limits
Zoning parameter | Maximum value |
|
|
Number of zone members in a zone | 2048 |
|
|
Number of zones in a zone set | 1024 |
|
|
Number of unique zone members in a zone set | 2048 |
|
|
Total number of zone members in a zone set (where a zone | 4096 |
member can be in multiple zones) |
|
|
|
Characters per zoning name | 32 |
|
|
Number of unique zone members in HAFM Zoning Library | 2048 |
|
|
Number of zones in HAFM Zoning Library | 1024 |
|
|
Number of zone sets in HAFM Zoning Library | 64 |
|
|
Number of end ports | 1024 |
|
|
Number of devices supported (including loop devices) | 1024 |
|
|
Using the same firmware
All directors and edge switches in the same fabric should have the same firmware level
The recently released Edge Switch 2/12 had an interim firmware specific for the Edge Switch 2/12,
Firmware
18