Disk Setup Issues

When selecting disks to partition, be careful not to select your internal disk.

To support third-party failover software products on dual controller single loop SANs, SAN Manager devices are listed twice as available disks when you run the Format utility. If you are using a dual controller single loop SAN, be careful to partition, create a file system, and mount only one instance of each SAN disk. For example, if c1 and c2 are the Fibre Channel controllers, then c1t17d0 and c2t17d0 refer to the same disk. If you partition, mount, or create file systems on both instances of a disk, data corruption will occur.

Partitioning a SAN Manager LM Disk for use with Solaris

1.Run the Format utility.

A list of available devices appears with a prompt to specify a disk. The following example is sample output from a one controller, one loop SAN configuration:

AVAILABLE DISK SELECTIONS:

0.c0t0d0 <Seagate Medalist 34342A cyl 8892 alt 2 hd 15 sec 63> /pci@1f,0/pci@1,1/ide@3/dad@0,0

1.c1t17d0 <SEAGATE-ST118202CLAR18-3525 cyl 6919 alt 2 hd 24 sec 214> /pci@1f,0/pci@1/scsi@1/sd_fcst@11,0

2.c1t127d20 <TR-UPM-4c72e14-1.00 cyl 54193 alt 2 hd 4 sec 640> /pci@1f,0/pci@1/scsi@1/sd_fcst@7f,14

3.c1t127d35 <TR-UPM-83c7723-1.00 cyl 6919 alt 2 hd 24 sec 214> /pci@1f,0/pci@1/scsi@1/sd_fcst@7f,23

4.c1t127d135 <TR-UPM-48e90487-1.00 cyl 6919 alt 2 hd 24 sec 214> /pci@1f,0/pci@1/scsi@1/sd_fcst@7f,87

5.c1t127d189 <TR-UPM-10a46fbd-1.00 cyl 6919 alt 2 hd 24 sec 214> /pci@1f,0/pci@1/scsi@1/sd_fcst@7f,bd

6.c1t127d250 <TR-UPM-5b3833fa-1.00 cyl 65441 alt 2 hd 1 sec 530> /pci@1f,0/pci@1/scsi@1/sd_fcst@7f,fa

Specify disk (enter its number):

22Preparing a Fibre Channel Disk for use with SAN Manager LM

Image 22
Contents Edition Warranty Format Conventions Preface Contents Page Installation System Requirements SAN Manager LM Packages SAN Manager LM Components File name DescriptionOn Solaris 7 Stations Only Remove the QLogic HBA Driver Pre-InstallationRemove the OEM QLogic HBA Driver Install a Fibre Channel HBA Card Into Each Computer Pre-Installation ChecklistHave the following available Installing SAN Manager LM Installation Adding a Node to the Database Automatically ConfigurationAdding a Node to the Database Manually Installation Configuration Storage Management Unknown/Raw Supported Partition Map FormatsUPM Format Preparing a Fibre Channel Disk for use with SAN Manager LM Slice Name ConventionsDisk Setup Issues Partitioning a SAN Manager LM Disk for use with SolarisDisk not labeled. Label it now? n Partition Tag Storage Management Creating a UFS File System # ls /dev/rdsk/c1# mkfs -F vxfs /dev/rdsk/device partitionsize Mounting UFS File Systems # mkdir /SAN # mkdir /SAN/fibre1Mounting File Systems Automatically Using the vfstab File SAN Manager LM Utilities SAN Manager LM Utilities Getwwn Getloopstate Troubleshooting No SAN Devices are Available on a Solaris Node Error During Mounting Not a block device SymptomCause/SolutionName=mydriver class=transcsi Ping -tipaddress Device Cannot be Disabled from a Solaris Node Device contains a mounted file system that is in use. StopIndex Page Reader Comment Sheet +HZOHWW3DFNDUG&RPSDQ\ 6RIWZDUHDQG6$10DQDJHPHQW2SHUDWLRQ Page RS\ULJKW‹