HP Microsoft Windows Server 2003 for Itanium-based Systems Completing the configuration process

Page 12

Typical Express Configuration mode screen

NOTE: Express mode is listed as a configuration option only if the controller that you select has unused space on an array or physical drives that are not assigned to an array.

Express Configuration mode screens are similar in appearance to Configuration Wizards mode screens ("Typical Configuration Wizards mode screen" on page 11), but the directive text is different. In Express Configuration mode, ACU asks you a few simple questions about your configuration preferences and then automatically sets up the optimum configuration based on your answers.

Completing the configuration process

Details of the subsequent steps in the configuration process are given in the remainder of this guide.

If the controller is not configured (it has no arrays or logical drives, only unassigned physical drives), refer to “Configuring a new controller (on page 13).”

If the controller is already configured but you want to reconfigure it, refer to “Modifying an existing configuration (on page 19).”

Getting started 12

Image 12
Contents HP Array Configuration Utility User Guide Audience assumptions Contents Diagnosing array problems Features and system requirements Installing ACUGetting started This sectionOverview for using ACU Setting the execution mode for Microsoft WindowsComparison of ACU execution modes Opening ACU in Local Application mode Choosing an operating modeOpening ACU in Browser mode Http//servername2301Opening ACU through Systems Insight Manager Select Device QueriesTypical Standard mode screen GUI operating modesTypical Configuration Wizards mode screen Completing the configuration process Typical Express Configuration mode screenConfiguring a new controller Using Standard Configuration modePossible tasks in Standard Configuration mode Using Express Configuration mode Using the configuration wizards Creating an arrayClick Finish Click Create an array, and then click BeginConfiguring a new controller Creating a logical drive Click Create a logical drive, and then click BeginConfiguring a new controller Modifying an existing configuration Modifying a configuration using Standard Configuration modeChoices available after opening ACU Modifying a configuration using Express mode Modifying a configuration using the Configuration wizardsClear Configuration Click Express Configuration, and then click BeginController settings Click Controller Settings, and then click BeginCreate an array Create a logical drive Delete arrays Delete logical drives Expand ArrayClick Delete logical drives, and then click Begin Extend logical drive Migrate a logical driveClick Extend logical drive, and then click Begin Click Migrate a logical drive, and then click BeginSpare management Selective Storage PresentationRA4x00 controllers Click Spare Management, and then click BeginMSA and Smart Array Cluster storage controllers Configuring switches Click ACU Switch ConfigurationSplitting a mirrored array Recombining a split, mirrored arrayModifying an existing configuration Command line syntax Scripting in ACUIntroduction to scripting in ACU Operating modesSample custom input script Cpqacuxe -i FilenameScript file options Description of option categories in ACU scriptingControl category Controller categoryAction MethodClearConfigurationWithDataLoss ControllerLicenseKey, DeleteLicenseKey RAIDArrayIDSurfaceScanDelay Array categoryRebuildPriority, ExpandPriority SSPStateLogical Drive category OnlineSpareDrive LogicalDriveSize SectorsStripeSize ArrayAcceleratorError reporting SSPAdaptersWithAccessConnectionName HostModeACU scripting error messages 0-9, !, @, #, *, , , ,, -, , +, , ., /, and space. The ID Current configuration Using the Command Line Interface Overview of the ACU CLIRunning the CLI Command variable CLI syntaxKeyword abbreviations Target variableTypical procedures Example commandHiding warning prompts Querying a deviceSample scenario SyntaxExample commands Modifying the controller chassis nameExample Using Selective Storage Presentation Sample scenarioModifying connection names Managing host modes connection profilesDeleting target devices Identifying devicesExpanding an array Extending a logical driveTarget modify raid=01+0156adg? ss=8163264128256default? Managing spare drivesMigrating a logical drive Target modify size=#max? forcedChanging the Rebuild Priority setting Changing the Expand Priority settingChanging the controller cache ratio Changing the surface scan delay time Re-enabling a failed logical driveEnabling or disabling the drive cache Setting the target Enabling or disabling the array acceleratorDisabling a redundant controller Typical scenarioRescanning the system = rescanProbability of logical drive failure Factors involved in logical drive failureProbability of logical drive failure Drive arrays and fault-tolerance methods Drive arraysDrive arrays and fault-tolerance methods Fault-tolerance methods Hardware-based fault-tolerance methodsRAID 0-No fault tolerance AdvantagesDisadvantages RAID 1+0-drive mirroring RAID 5-distributed data guarding RAID 6 ADG-Advanced Data GuardingComparing the hardware-based RAID methods RAID RAID 6 ADGAlternative fault-tolerance methods Selecting a RAID methodDiagnosing array problems Diagnostic toolsServer Diagnostics Post messagesAcronyms and abbreviations SSP Index Index