HP Microsoft Windows Server 2003 for Itanium-based Systems manual ACU scripting error messages

Page 40

ACU scripting error messages

Message

Comment or explanation (if not self-explanatory)

 

 

(text) is not a controller command

--

 

 

(text) is not a logical drive

--

command

 

 

 

(text) is not a supported command

--

 

 

(text) is not an array command

--

 

 

(text) command expected

The specified command is missing or in the incorrect place in the

 

file.

 

 

Array not specified

Some commands in the script require an array, but no array is

 

specified in the script file.

Array requires an odd number of

This error message occurs if you attempt to add an odd number of

drives

drives to an existing array that has RAID 1 logical drives, and the

 

controller does not support RAID-level migration.

 

 

Cannot change array spare

The current configuration does not allow the number of spares in the

 

array to be changed.

Cannot change logical drive array

The current controller configuration does not allow the array

accelerator setting

accelerator setting to be changed.

 

 

Cannot change logical drive

You cannot change the MaxBoot setting on a configured logical

sectors

drive because doing so causes data loss.

 

 

Cannot change SSP settings

--

 

 

Cannot create array

The controller either has no unassigned physical drives, or it already

 

has the maximum number of arrays or logical drives.

Cannot create logical drive

There is no free space on the array, or the maximum number of

 

logical drives has already been reached.

 

 

Cannot expand array

The controller does not support expansion, or the current

 

configuration of the controller does not allow expansion.

 

 

Cannot extend logical drive

The controller does not support extension, or the current

 

configuration does not allow extension. For example, if there is no

 

free space on an array, extension is not supported.

 

 

Cannot migrate logical drive RAID

The controller does not support RAID migration, or the current

 

configuration of the controller does not allow migration.

 

 

Cannot migrate logical drive stripe

The controller does not support stripe size migration, or the current

size

configuration of the controller does not allow migration.

Cannot remove physical drives

You have inadvertently omitted one or more physical drives from the

from existing array

drive list when reconfiguring an existing array. ACU does not allow

 

this because removing physical drives from a configured array

 

causes data loss.

Controller (text) is invalid

The controller specifications are not entered correctly.

 

 

Controller does not support

--

controller SSPState. Use the

 

LogicalDriveSSPState command to

 

set SSP states for each logical

 

drive.

 

 

 

Controller does not support license

--

keys

 

 

 

Scripting in ACU 40

Image 40
Contents HP Array Configuration Utility User Guide Audience assumptions Contents Diagnosing array problems Features and system requirements Installing ACUGetting started This sectionSetting the execution mode for Microsoft Windows Overview for using ACUComparison of ACU execution modes Opening ACU in Local Application mode Choosing an operating modeOpening ACU in Browser mode Http//servername2301Opening ACU through Systems Insight Manager Select Device QueriesTypical Standard mode screen GUI operating modesTypical Configuration Wizards mode screen Completing the configuration process Typical Express Configuration mode screenUsing Standard Configuration mode Configuring a new controllerPossible tasks in Standard Configuration mode Using Express Configuration mode Using the configuration wizards Creating an arrayClick Finish Click Create an array, and then click BeginConfiguring a new controller Creating a logical drive Click Create a logical drive, and then click BeginConfiguring a new controller Modifying a configuration using Standard Configuration mode Modifying an existing configurationChoices available after opening ACU Modifying a configuration using Express mode Modifying a configuration using the Configuration wizardsClear Configuration Click Express Configuration, and then click BeginClick Controller Settings, and then click Begin Controller settingsCreate an array Create a logical drive Delete arrays Expand Array Delete logical drivesClick Delete logical drives, and then click Begin Extend logical drive Migrate a logical driveClick Extend logical drive, and then click Begin Click Migrate a logical drive, and then click BeginSpare management Selective Storage PresentationRA4x00 controllers Click Spare Management, and then click BeginMSA and Smart Array Cluster storage controllers Configuring switches Click ACU Switch ConfigurationSplitting a mirrored array Recombining a split, mirrored arrayModifying an existing configuration Command line syntax Scripting in ACUIntroduction to scripting in ACU Operating modesSample custom input script Cpqacuxe -i FilenameScript file options Description of option categories in ACU scriptingControl category Controller categoryAction MethodClearConfigurationWithDataLoss ControllerLicenseKey, DeleteLicenseKey RAIDArrayIDSurfaceScanDelay Array categoryRebuildPriority, ExpandPriority SSPState Logical Drive category OnlineSpare Drive LogicalDriveSize SectorsStripeSize ArrayAcceleratorError reporting SSPAdaptersWithAccessConnectionName HostModeACU scripting error messages 0-9, !, @, #, *, , , ,, -, , +, , ., /, and space. The ID Current configuration Overview of the ACU CLI Using the Command Line InterfaceRunning the CLI Command variable CLI syntaxKeyword abbreviations Target variableTypical procedures Example commandHiding warning prompts Querying a deviceSample scenario SyntaxModifying the controller chassis name Example commandsExample Using Selective Storage Presentation Sample scenarioModifying connection names Managing host modes connection profilesDeleting target devices Identifying devicesExpanding an array Extending a logical driveTarget modify raid=01+0156adg? ss=8163264128256default? Managing spare drivesMigrating a logical drive Target modify size=#max? forcedChanging the Expand Priority setting Changing the Rebuild Priority settingChanging the controller cache ratio Re-enabling a failed logical drive Changing the surface scan delay timeEnabling or disabling the drive cache Setting the target Enabling or disabling the array acceleratorDisabling a redundant controller Typical scenarioRescanning the system = rescanProbability of logical drive failure Factors involved in logical drive failureProbability of logical drive failure Drive arrays and fault-tolerance methods Drive arraysDrive arrays and fault-tolerance methods Fault-tolerance methods Hardware-based fault-tolerance methodsAdvantages RAID 0-No fault toleranceDisadvantages RAID 1+0-drive mirroring RAID 5-distributed data guarding RAID 6 ADG-Advanced Data GuardingComparing the hardware-based RAID methods RAID RAID 6 ADGAlternative fault-tolerance methods Selecting a RAID methodDiagnosing array problems Diagnostic toolsServer Diagnostics Post messagesAcronyms and abbreviations SSP Index Index