ACU scripting error messages
Message | Comment or explanation (if not |
|
|
(text) is not a controller command | |
|
|
(text) is not a logical drive | |
command |
|
|
|
(text) is not a supported command | |
|
|
(text) is not an array command | |
|
|
(text) command expected | The specified command is missing or in the incorrect place in the |
| file. |
|
|
Array not specified | Some commands in the script require an array, but no array is |
| specified in the script file. |
Array requires an odd number of | This error message occurs if you attempt to add an odd number of |
drives | drives to an existing array that has RAID 1 logical drives, and the |
| controller does not support |
|
|
Cannot change array spare | The current configuration does not allow the number of spares in the |
| array to be changed. |
Cannot change logical drive array | The current controller configuration does not allow the array |
accelerator setting | accelerator setting to be changed. |
|
|
Cannot change logical drive | You cannot change the MaxBoot setting on a configured logical |
sectors | drive because doing so causes data loss. |
|
|
Cannot change SSP settings | |
|
|
Cannot create array | The controller either has no unassigned physical drives, or it already |
| has the maximum number of arrays or logical drives. |
Cannot create logical drive | There is no free space on the array, or the maximum number of |
| logical drives has already been reached. |
|
|
Cannot expand array | The controller does not support expansion, or the current |
| configuration of the controller does not allow expansion. |
|
|
Cannot extend logical drive | The controller does not support extension, or the current |
| configuration does not allow extension. For example, if there is no |
| free space on an array, extension is not supported. |
|
|
Cannot migrate logical drive RAID | The controller does not support RAID migration, or the current |
| configuration of the controller does not allow migration. |
|
|
Cannot migrate logical drive stripe | The controller does not support stripe size migration, or the current |
size | configuration of the controller does not allow migration. |
Cannot remove physical drives | You have inadvertently omitted one or more physical drives from the |
from existing array | drive list when reconfiguring an existing array. ACU does not allow |
| this because removing physical drives from a configured array |
| causes data loss. |
Controller (text) is invalid | The controller specifications are not entered correctly. |
|
|
Controller does not support | |
controller SSPState. Use the |
|
LogicalDriveSSPState command to |
|
set SSP states for each logical |
|
drive. |
|
|
|
Controller does not support license | |
keys |
|
|
|
Scripting in ACU 40