HP Microsoft Windows Server 2003 for Itanium-based Systems manual

Page 41

Message

Comment or explanation (if not self-explanatory)

 

 

 

 

Controller does not support logical

--

 

drive SSP states. Use the SSPState

 

 

command to set the controller SSP

 

 

state.

 

 

 

 

 

Controller does not support

The controller is not redundant or does not support redundancy

 

redundancy settings

settings.

 

Controller does not support

--

 

RAIDArrayID

 

 

 

 

 

Controller does not support SSP

--

 

 

 

 

Controller has maximum number

--

 

of license keys

 

 

 

 

 

Controller is locked by another

--

 

machine or user

 

 

Controller requires non-failed

--

 

physical drives to set license keys

 

 

 

 

 

Controller requires physical drives

--

 

to set license keys

 

 

 

 

 

Could not detect controller (text)

--

 

 

 

 

Error communicating with

--

 

controller

 

 

Error saving controller

There is a problem saving one or more controller configurations.

 

 

 

 

Failure opening capture file (text)

--

 

 

 

 

Failure opening input file (text)

--

 

 

 

 

Internal error

An internal ACU error has occurred, and some error is not being

 

 

identified properly.

 

 

 

 

Invalid array accelerator setting

The specified array accelerator setting is invalid or is not supported

 

 

with the current configuration.

 

 

 

 

Invalid array

The array ID is invalid.

 

 

 

 

Invalid

--

 

ClearConfigurationWithDataLoss

 

 

parameter

 

 

 

 

 

Invalid Controller

--

 

 

 

 

Invalid expand priority

The specified expand priority is not supported, or the controller does

 

 

not allow expansion and therefore does not support the Expand

 

 

Priority feature.

 

Invalid license key

--

 

 

 

 

Invalid logical drive

The logical drive ID is not valid.

 

 

 

 

Invalid Method

Invalid Method value.

 

 

 

 

Invalid physical drive

The physical drive listed for the array is not a valid physical drive,

 

 

or it is a physical drive that is not capable of being placed in the

 

 

array.

 

 

 

 

Invalid RAIDArrayID

The entered RAIDArrayID is invalid. Use characters from the set a–z,

 

 

A–Z, 0–9, !, @, #, *, (, ), ,, -, _, +, :, ., /, and [space]. The ID

 

 

cannot end with a space character or exceed the maximum number

 

 

of characters allowed by the controller.

 

 

 

 

Invalid RAID

The specified RAID level is invalid or is not possible with the current

 

 

configuration.

 

 

Scripting in ACU 41

Image 41
Contents HP Array Configuration Utility User Guide Audience assumptions Contents Diagnosing array problems Installing ACU Features and system requirementsGetting started This sectionComparison of ACU execution modes Overview for using ACUSetting the execution mode for Microsoft Windows Choosing an operating mode Opening ACU in Local Application modeHttp//servername2301 Opening ACU in Browser modeSelect Device Queries Opening ACU through Systems Insight ManagerGUI operating modes Typical Standard mode screenTypical Configuration Wizards mode screen Typical Express Configuration mode screen Completing the configuration processPossible tasks in Standard Configuration mode Configuring a new controllerUsing Standard Configuration mode Using Express Configuration mode Creating an array Using the configuration wizardsClick Finish Click Create an array, and then click BeginConfiguring a new controller Click Create a logical drive, and then click Begin Creating a logical driveConfiguring a new controller Choices available after opening ACU Modifying an existing configurationModifying a configuration using Standard Configuration mode Modifying a configuration using the Configuration wizards Modifying a configuration using Express modeClear Configuration Click Express Configuration, and then click BeginCreate an array Controller settingsClick Controller Settings, and then click Begin Create a logical drive Delete arrays Click Delete logical drives, and then click Begin Delete logical drivesExpand Array Migrate a logical drive Extend logical driveClick Extend logical drive, and then click Begin Click Migrate a logical drive, and then click BeginSelective Storage Presentation Spare managementRA4x00 controllers Click Spare Management, and then click BeginMSA and Smart Array Cluster storage controllers Click ACU Switch Configuration Configuring switchesRecombining a split, mirrored array Splitting a mirrored arrayModifying an existing configuration Scripting in ACU Command line syntaxIntroduction to scripting in ACU Operating modesCpqacuxe -i Filename Sample custom input scriptDescription of option categories in ACU scripting Script file optionsController category Control categoryAction MethodController ClearConfigurationWithDataLossLicenseKey, DeleteLicenseKey RAIDArrayIDArray category SurfaceScanDelayRebuildPriority, ExpandPriority SSPStateOnlineSpare Logical Drive categoryDrive LogicalDrive Sectors Size StripeSize ArrayAcceleratorSSPAdaptersWithAccess Error reportingConnectionName HostModeACU scripting error messages 0-9, !, @, #, *, , , ,, -, , +, , ., /, and space. The ID Current configuration Running the CLI Using the Command Line InterfaceOverview of the ACU CLI CLI syntax Command variableKeyword abbreviations Target variableExample command Typical proceduresHiding warning prompts Querying a deviceSyntax Sample scenarioExample Example commandsModifying the controller chassis name Sample scenario Using Selective Storage PresentationManaging host modes connection profiles Modifying connection namesIdentifying devices Deleting target devicesExpanding an array Extending a logical driveManaging spare drives Target modify raid=01+0156adg? ss=8163264128256default?Migrating a logical drive Target modify size=#max? forcedChanging the controller cache ratio Changing the Rebuild Priority settingChanging the Expand Priority setting Enabling or disabling the drive cache Changing the surface scan delay timeRe-enabling a failed logical drive Enabling or disabling the array accelerator Setting the targetDisabling a redundant controller Typical scenario= rescan Rescanning the systemFactors involved in logical drive failure Probability of logical drive failureProbability of logical drive failure Drive arrays Drive arrays and fault-tolerance methodsDrive arrays and fault-tolerance methods Hardware-based fault-tolerance methods Fault-tolerance methodsDisadvantages RAID 0-No fault toleranceAdvantages RAID 1+0-drive mirroring RAID 6 ADG-Advanced Data Guarding RAID 5-distributed data guardingRAID RAID 6 ADG Comparing the hardware-based RAID methodsSelecting a RAID method Alternative fault-tolerance methodsDiagnostic tools Diagnosing array problemsServer Diagnostics Post messagesAcronyms and abbreviations SSP Index Index