HP UX System Management Software Updating from HP-UX 11i v3 0903 to HP-UX 11i v3 1103 slide 3

Page 15

DRD use case

Updating from HP-UX 11i v3 0903 to HP-UX 11i v3 1103 (slide 3 of 3)

Patches

SWA

Report

1.

Original system image is active

2.

Create a clone of the original system image

 

(drd clone)

3.

When complete, two copies of system image

 

exist (drd status)

4.

Update the inactive image to HP-UX 11i v3

 

March 2009 or later (1103 or March 2011 in

 

this case) (drd runcmd update-ux)

5.

When modification completes, have an

 

original image with HP-UX 11i v3 0903,

 

and a modified clone with HP-UX 11i v3 1103

6.

Use SWA to identify patches & fixes to security

HP-UX 11i v3 0903

HP-UX 11i v3 1103

Modified clone

Active

 

issues (drd mount, swa report, drd umount)

7.

Install required patches (swa get, drd runcmd

 

swinstall)

8.

Boot the clone when ready (drd activate)

9.

If original system preferred, boot the

 

unmodified original image to return to

 

original state (drd activate)

15

Image 15
Contents Dynamic Root Disk Agenda Mission/benefits DRD overviewDRD use models DRD use case RecoveryMaintenance slide 1 Swinstall Maintenance slide 2Maintenance slide 3 High Availability with DRD and MirrorDisk/UX slide 1 High Availability with DRD and MirrorDisk/UX slide 2 High Availability with DRD and MirrorDisk/UX slide 3 High Availability with DRD and MirrorDisk/UX DRD Customer use modelsUpdating from HP-UX 11i v3 0903 to HP-UX 11i v3 1103 slide 1 Updating from HP-UX 11i v3 0903 to HP-UX 11i v3 1103 slide 2 Updating from HP-UX 11i v3 0903 to HP-UX 11i v3 1103 slide 3 Updating from HP-UX 11i v2 to HP-UX 11i v3 1103 slide 1 Updating from HP-UX 11i v2 to HP-UX 11i v3 1103 slide 2 Updating from HP-UX 11i v2 to HP-UX 11i v3 1103 slide 3 Updating from HP-UX 11i v2 to HP-UX 11i v3 1103 slide 4 BL2 BL6 Rehosting Provisioning blade example, slide 1Rehosting Provisioning blade example, slide 2 Rehosting Is Rehosting Is not Additional software is not installed by drd rehostRehosting Additional information 11i Maintaining a mixed 11i v2/v3 VM environment slide 1Active Maintaining a mixed 11i v2/v3 VM environment slide 2DRD Status & DRD Sync DRD status Without DRD Sync DRD syncImage Trimming the list of files to be synchronized DRD sync algorithmDRD real-life examples Without DRD Scenario 1 Maintenance of an 11i v3 IA systemDowntime reduction ~58% Without DRD Scenario 2 Updating an HP-UX 11i v3 IA systemWith DRD DRD sample timeline with command examples Wrap-up More information Thank YOU
Related manuals
Manual 41 pages 43.08 Kb Manual 275 pages 32.3 Kb