Soleus Air KFTHP-24 automatically with the AUTO FAN speed, Low Speed, 80.6, Stop the fan

Page 7
4.“DRY” Mode Operation

TCL Air Conditioner Service Manual

Room Temp.

 

 

 

 

 

Set TEMP. 1.8

 

 

 

 

 

Set TEMP. 1.8

 

 

 

 

 

Time

More than 2 min

More than 2 min

More than 2 min

More than 2 min

More than 2 min

Indoor Fan

Set Speed

Set Speed

Set Speed

Set Speed

Set Speed

Compressor

ON

OFF

ON

OFF

ON

Outdoor Fan

ON

OFF

ON

OFF

ON

4.“DRY” Mode Operation

(1)The system for DRY operation used the same refrigerant circle as the cooling circle.

(2)When the system operates in DRY mode ,at first it operates in cooling mode at 60.8℉ or 64.4℉ for 3 minutes. And then, the system operates in cooling mode with low speed that regards the temperature of the room temperature sensor reads decrease 35.6as the set temperature. During the course of this, the fan speed set operation is failing but the vane motor can be controlled.

5.“HEATING” Mode Operation (Only available for Heat Pump)

(1)When the HEATING mode is selected without setting temperature, the system will set the temperature at

73.4℉ automatically with the AUTO FAN speed.

(2)When selecting the HEATING mode operation, the system will operate according to the setting by the remote controller and the operation is as following:

Set Temp. 1.8

Set Temp. 1.8

Room Temp.

Time

More than 2 min

More than 2 min

More than 2 min

More than 2 min

More than 2 min

Compressor

ON

OFF

ON

OFF

ON

 

 

 

 

 

 

Outdoor fan

ON

OFF

ON

OFF

ON

(3)In HEATING mode, the indoor fan motor speed is controlled by Cold Air Prevention Control.

(4)Cold Air Prevention Control

The function is intend to prevent cold air from being discharged when the heating operation starts or when defrosting.

The indoor fan speed will be controlled as following. The vane angle is at the angle C(100°).

Temperatureraise

Set Speed

Set Speed

 

 

 

Low Speed

Temperaturedrop

9 3 . 2

 

 

 

 

Low Speed

 

 

 

 

 

80.6℉

 

 

 

 

 

77

Stop the fan

73.4

Stop the fan

During the heating operation, if the compressor stops that it will adjust the indoor fan speed, after 30 seconds to stop the fan.

7

Image 7
Contents WALL MOUNTED SPLIT-TYPEAIR CONDITIONERS ModelsCONTENTS KFTHP-12 KFTHP-18 KFTHP-24IMPORTANT NOTICE How to order spare partsKFTHP-18 Technical SpecificationsModel No KFTHP-12Remote Control 1Remote controllerRemote controller 2TIMER buttonThe four types of remote controller is as follow REMOTE CONTROLLERElectronic Controller 80.6 73.4 automatically with the AUTO FAN speedLow Speed Low SpeedaIPT1 satisfy IPT1=IPTMAX-IPT(14.4) 8.“SLEEP” mode Defrosting time chart6.“FAN” mode operation 7.4-wayValve control2Positioning 12.TIMER Operation11.Auto Vane Operation control 1Vane motor drive14.AUTO RESTART FunctionOption 13.EMERGENCY Operation15.Failure Display and Handling dDisplay Of The Control MODEL KFTHP-12 ELECTRICAL SCHEMATIC DIAGRAMMODEL KFTHP-18 ELECTRICAL SCHEMATIC DIAGRAMMODEL KFTHP-24 ELECTRICAL SCHEMATIC DIAGRAMMODEL KFTHP-12 INDOOR UNIT EXPLOSION VIEWMODEL KFTHP-18 INDOOR UNIT EXPLOSION VIEWMODEL: KFTHP-24 INDOOR UNIT EXPLOSION VIEWMODEL KFTHP-12 OUTDOOR UNIT EXPLOSION VIEWMODEL KFTHP-18 OUTDOOR UNIT EXPLOSION VIEWMODEL KFTHP-24 OUTDOOR UNIT EXPLOSION VIEWIndoor Unit- KFTHP-12 Part ListIndoor Unit- KFTHP-18 Part ListQ’ty Indoor Unit- KFTHP-24 Part ListOutdoor Unit- KFTHP-12 Part ListQ’ty Outdoor Unit- KFTHP-18 Part ListOutdoor Unit- KFTHP-24 Part List