Soleus Air KFTHP-18 Auto Vane Operation control, 1Vane motor drive, 2Positioning, TIMER Operation

Page 10
10.Auto Fan Speed Control

TCL Air Conditioner Service Manual

motor is shut off. 10 seconds later, the electric current is applied to the fan motor again. During the fan motor lock-up, the POWER indicator lamp flashes on and off 6times/cycle or E6 to show the fan motor abnormality.

10.Auto Fan Speed Control

(1)When the auto fan speed is selected, the indoor fan motor speed is automatically controlled by the room temperature and the set temperature.

(2)In COOLING mode, the indoor fan motor operates as following:

Fan Speed

 

 

 

Hi

 

 

 

Me

 

 

 

Lo

 

 

 

Room temperature minus set temperature:

1.8℉

3.6℉

7.2℉

(3)In HEATING mode, the indoor fan motor operates as following; Fan Speed

Hi

Mi

 

 

Lo

 

 

Room temperature minus set temperature

1 .8℉ 3.6℉

7.2℉

11.Auto Vane Operation control

(1)Vane motor drive

The unit is equipped with a stepping motor for the vane. The rotating direction, speed, and angle of the motor are controlled by pulse signal transmitted from indoor microprocessor.

(2)Positioning

The vane is once pressed to the vane stopper below to confirm the standard position and then set to the desired angle. The positioning is decided as follows:

When the ON/OFF button is pressed.

When the vane control is change from AUTO to MANUAL. When the SWING is finished.

When the test run starts.

When the power supply turns ON.

(3)The auto vane changes as follows by pressing the VANE CONTROL button.

(4)VANE AUTO mode

In vane auto mode, the microprocessor automatically determines the vane angle and operation to make the optimum room-temperature distribution.

(5)SWING mode

When presses the SWING button, the vane swings.

12.TIMER Operation

(1)To activate the air conditioner at the desire time, follow the procedure specified below(the remote control and air conditioner are switched off):

Press the Timer button.

Select the desired mode by pressing the Mode button.

Select the desired temperature by pressing the ▲ ▼ button(only possible when the ‘cool’ or ‘heat’ mode is selected).

Select the ventilator speed (low, medium or high) or automatic mode(only possible when the feel, Cool or Heat mode is selected) by pressing the Fan button.

The ventilator always operates in the Auto mode when the Dry mode is selected. Select Swing or no Swing by pressing the Swing button.

1 0

Image 10
Contents KFTHP-12 KFTHP-18 KFTHP-24 ModelsCONTENTS WALL MOUNTED SPLIT-TYPEAIR CONDITIONERSHow to order spare parts IMPORTANT NOTICEKFTHP-12 Technical SpecificationsModel No KFTHP-182TIMER button 1Remote controllerRemote controller Remote ControlREMOTE CONTROLLER The four types of remote controller is as followElectronic Controller Low Speed 73.4 automatically with the AUTO FAN speedLow Speed 80.6aIPT1 satisfy IPT1=IPTMAX-IPT(14.4) 7.4-wayValve control Defrosting time chart6.“FAN” mode operation 8.“SLEEP” mode1Vane motor drive 12.TIMER Operation11.Auto Vane Operation control 2Positioning14.AUTO RESTART FunctionOption 13.EMERGENCY Operation15.Failure Display and Handling dDisplay Of The Control ELECTRICAL SCHEMATIC DIAGRAM MODEL KFTHP-12ELECTRICAL SCHEMATIC DIAGRAM MODEL KFTHP-18ELECTRICAL SCHEMATIC DIAGRAM MODEL KFTHP-24EXPLOSION VIEW MODEL KFTHP-12 INDOOR UNITEXPLOSION VIEW MODEL KFTHP-18 INDOOR UNITEXPLOSION VIEW MODEL: KFTHP-24 INDOOR UNITEXPLOSION VIEW MODEL KFTHP-12 OUTDOOR UNITEXPLOSION VIEW MODEL KFTHP-18 OUTDOOR UNITEXPLOSION VIEW MODEL KFTHP-24 OUTDOOR UNITPart List Indoor Unit- KFTHP-12Indoor Unit- KFTHP-18 Part ListQ’ty Part List Indoor Unit- KFTHP-24Outdoor Unit- KFTHP-12 Part ListQ’ty Part List Outdoor Unit- KFTHP-18Part List Outdoor Unit- KFTHP-24