HP manual HP ProLiant DL120 G6 Models Standard Memory, Standard Memory Plus Optional Memory

Page 24

QuickSpecs

HP ProLiant DL120 Generation 6

Memory

HP ProLiant DL120 G6 Models

NOTE: Memory configurations listed do not apply to "Factory Integrated Models".

Standard Memory

SATA Models:

4GB of PC3-10600E DDR3 UDIMM running at 1333MHz with ECC capabilities memory installed.

SAS Models

4GB of PC3-10600R RDIMM running at 1333MHz

Standard Memory Plus Optional Memory

Up to 16 GB memory is available with the optional installation of 4 x 4GB PC3-10600E UDIMM ECC DDR3 SDRAM DIMM Memory kits.

Up to 12GB memory is available with the optional installation of 6 x 2GB PC3-10600R RDIMM DDR3 SDRAM DIMM Memory kits

Up to 16 GB memory is available with the optional installation of 4 x 4GB PC3-8500R RDIMM DDR3 DIMM Memory kits.

NOTE: The below chart does not represent all possible memory configurations.

NOTE: For best performance, it is recommended that customer installs memory in identical pairs (Slots 1 and 3 are interleaving pair. Slots 2 and 4 are interleaving pair).

Some DIMM installation guidelines are summarized below:

For the HP ProLiant DL120 G6 server with six (6) memory slots There are two (2) channels per server

There are three (3) DIMM slots for each memory channel; six (6) total slots Memory channel 1 consists of the three (3) DIMMs that are closest to the processor Memory channel 2 consists of the three (3) DIMMs that are furthest from the processor Different processor (CPU) has different memory support

Do not mix Unbuffered memory (UDIMMs) with Registered memory (RDIMMs)

It is not required, but it is recommended to load the channels similarly if possible Support up to 4 DIMMs (2 DIMMs per channel) max 8GB PC3 10600E (DDR3 1333 MHz) Support up to 4 DIMMs ( 2 DIMMs per channel) max 16GB PC3-8500R (DDR3-1066 MHz)

Support up to 6 DIMMs (3 DIMMs per channel) max 12GB PC3-10600R (DDR3-1333 MHz). Support single, double and quad ranks of DIMM

Populate DIMMs from heaviest load (double-rank) to lightest load (single-rank) within a channel Heaviest load (DIMM with most ranks) within a channel goes furthest from the CPU

No mixing DIMM voltage; all DIMMs must be the same voltage

The UDIMM installing sequence:

 

DIMM1E

DIMM2C

DIMM3A

DIMM4F

DIMM5D

DIMM6B

1 DIMMs

Empty

Empty

DIMM

Empty

Empty

Empty

2 DIMMs

Empty

Empty

DIMM

Empty

Empty

DIMM

4 DIMMs

Empty

DIMM

DIMM

Empty

DIMM

DIMM

The RDIMM installing sequence:

 

 

 

 

 

 

DIMM1E

DIMM2C

DIMM3A

DIMM4F

DIMM5D

DIMM6B

1 DIMMs

Empty

Empty

DIMM

Empty

Empty

Empty

2 DIMMs

Empty

Empty

DIMM

Empty

Empty

DIMM

4 DIMMs

Empty

DIMM

DIMM

Empty

DIMM

DIMM

6 DIMMs

DIMM

DIMM

DIMM

DIMM

DIMM

DIMM

DA - 13504 Worldwide QuickSpecs — Version 8 — 8/20/2010

Page 24

Image 24
Contents Overview Front View Rear ViewProcessor MemoryUSB 2.0 Ports Form FactorStandard Features Quad-Core ProcessorsDual-Core Processors Network Controller PCI-XStorage Maximum InternalStorage Type InterfacesHP Insight Control Insight Control server Management software deploymentCore Server ProLiant 100 Series G6 Management Core ManagementIndex.html Industry Standard ComplianceIntelligent SecurityServer Power Cords North America Power SupplySystem Fans Dual rotor fans ship standard Configurator Service and SupportRack Kit Telco Rack KitQuickSpecs Models Configuration Information Factory Integrated Models ModelsIncludes HP Processor Quad-CoreHP Power Supplies Registered DIMMs RdimmHP Hard Drives SAS Non-Hot Plug LFF 3.5-inch Enterprise ENT DrivesChoose Additional Factory Integratable Options Core Options HP Unique OptionsHP Memory HP Optical DrivesSata Hot Plug LFF 3.5-inch Midline MDL Drives Sata Hot Plug LFF 3.5-inch Entry ETY DrivesHP Networking HP I/O ExpansionOptions Additional Options Scsi HBA HP Disk Backup HP Monitored Power Distribution Unit Half Rack Version Modular Power Distribution Units 1U/0U Up to 32 outletsHP Rack Series HP Rack Options HP KVM Switch Options HP Care Pack Services Hardware Services On-site ServiceHardware Services Next Business Day On-Site Service Installation ServicesMemory HP ProLiant DL120 G6 Models Standard MemoryStandard Memory Plus Optional Memory Registered DIMMs Rdimm Storage Quantity Position Supported Controller Removable MediaQuickSpecs HP StorageWorks USB HP StorageWorks SASTape Autoloaders Tape LibrariesRDX Removable Disk Backup System Backup Systems, iSCSIBackup Systems, Fibre HP StorageWorks FibreTechnical Specifications Power Supply Input voltage Specifications Input SpecificationsAmbient temperature Acoustic Noise Emissions Classification EMCFeature RAID levels supported RAID FeaturesIntegrated Serial ATA Simultaneous drive Controller Transfer channels Transfer rateWarranty Hard Drive Native CommandPhysical Configuration Bytes/Sector Capacity