QuickSpecs
HP ProLiant DL120 Generation 6
Technical Specifications
Acoustic Noise
Emissions
Classification (EMC)
Listed are the declared
74)and declared in accordance with ISO 9296 (ECMA 109).
Idle
LWAd | 6.30 B |
LpAm | 44.1 dBA |
Operating |
|
LWAd | 6.34 B |
LpAm | 44.4 dBA |
FCC Rating | Class A |
Normative Standards | CISPR 22; EN55022; EN55024; FCC CFR 47, |
| Pt 15; |
| |
|
NOTE: Product conformance to cited product specifications is based on sample (type) testing, evaluation, or assessment. This product or family of products is eligible to bear the appropriate compliance logos and statements.
Power Supply | Input voltage | Rated input voltage | 100 VAC to 240 VAC |
| specifications |
|
|
| Input Specifications | Rated input line | 90 VAC to 264VAC |
|
| Frequency range | 47 to 63 Hz |
|
| Rated input power | @ 115V input, Rated input power = 500W |
|
|
| (assume output wattage=400W |
|
|
| @ 230V input, Rated input power = 500W |
|
|
| (assume output wattage=400W) |
|
| Rated input current | 6 A, 3 A (110 V, 220 V) |
|
| Steady state power | 400W (rated) |
| BTU Rating | 1710 BTU/hr |
|
| Ambient temperature | Operating | 41° to 122° F (5° to 50° C) |
| range | ||
| Relative humidity | Operating | 5% to 95% |
| 5% to 95% | ||
| Dielectric voltage | Input to output | 2150 VDC minimum, withstand 1 min |
| withstand | Input to ground | 2150 VDC minimum, withstand 1 min |
| Maximum Wet Bulb | 104° F (40° C) |
|
| Temperature |
|
|
|
|
|
|
DA - 13504 Worldwide QuickSpecs — Version 8 — 8/20/2010 | Page 31 |