QuickSpecs
HP ProLiant DL120 Generation 6
Technical Specifications
System Unit | Dimensions (H x W x D) 4.32 x 44.81 x 70.0 mm (1.69" x 17.64" x 27.56") | ||
| (with bezel) |
|
|
| Weight | Maximum | 31.49 lb (14.3kg) |
| (approximate) | (four hard drives, power |
|
|
| supply, and processor |
|
|
| installed) |
|
|
| Minimum | 28.2lb (12.8kg) |
|
| (one hard drive, power |
|
|
| supply, and processor |
|
|
| installed) |
|
| Input Requirements | Range Line Voltage | 90 - 132 VAC, |
| (per power supply) |
| 180 - 264 VAC |
|
| Rated Input Current | 6 A (at 100 VAC), |
|
|
| 3 A (at 200 VAC) |
|
| Rated Input Frequency | 47 to 63 Hz |
|
| Rated Input Power | <550W (at 100 VAC) |
|
|
| 550W (at 200 VAC) |
| BTU Rating | Maximum | 1314 BTU/hr (at 100 VAC), |
|
|
| 1314 BTU/hr (at 200 VAC) |
| Power Specifications | To review typical system power ratings use the Power Advisor which is | |
|
| available via the online tool located at URL: www.hp.com/go/proliant- | |
|
| ||
|
| - Click on the system of interest. Example: DL120 G6 | |
|
| - Follow the instructions of the next screens. | |
| Power Supply Output | Rated | 400 W (at 100 VAC), |
| (per power supply) | Power | 400 W (at 200 VAC) |
|
| Maximum Peak Power | 430 W (at 100 VAC), |
|
|
| 430 W (at 200 VAC) |
| System Inlet | Operating | 10° to 35°C (50° to 95°F) at sea level with an |
| Temperature |
| altitude derating of 1.0°C per every 305 m |
|
|
| (1.8°F per every 1000 ft) above sea level to a |
|
|
| maximum of 3050 m (10,000 ft), no direct |
|
|
| sustained sunlight. Maximum rate of change |
|
|
| is 10°C/hr (18°F/hr). The upper limit may be |
|
|
| limited by the type and number of options |
|
|
| installed. |
|
|
| System performance may be reduced if |
|
|
| operating with a fan fault or above 30°C |
|
|
| (86°F). |
|
| ||
|
|
| change is 20°C/hr (36°F/hr). |
| Relative Humidity | Operating | 10 to 90% relative humidity (Rh), 28°C |
|
| (82.4°F) maximum wet bulb temperature, non- | |
|
|
| condensing. |
|
| 5 to 95% relative humidity (Rh), 38.7°C | |
|
|
| (101.7°F) maximum wet bulb temperature, |
|
|
| |
| Altitude | Operating | 3050 m (10,000 ft). This value may be limited |
|
|
| by the type and number of options installed. |
|
|
| Maximum allowable altitude change rate is |
|
|
| 457 m/min (1500 ft/min). |
|
| 9144 m (30,000 ft). Maximum allowable | |
|
|
| altitude change rate is 457 m/min (1500 |
|
|
| ft/min). |
DA - 13504 Worldwide QuickSpecs — Version 8 — 8/20/2010 | Page 30 |