HP 400t manual QuickSpecs

Page 20

QuickSpecs

HP StorageWorks 400t and 400r All-in-One

Storage Systems

Technical Specifications

Specifications

Weight

All hard drives, power

37.00 lb (16.78 kg)

 

 

(approximate)

supplies, and processors

 

 

 

installed

 

 

Input Requirements

Rated Line Voltage

90 to 132 VAC,

 

(per power supply)

 

180 to 264 VAC

 

 

Rated Input Current

7.31A at 115VAC,

 

 

 

3.6A at 230VAC

 

 

Rated Input Frequency

47 to 63 Hz

 

 

Rated Input Power

855W (at 100 VAC),

 

 

 

840.72W (at 200 VAC)

 

Power Specifications

To review typical system power ratings use the Power Calculator which is

 

 

available via the online tool located at URL:

 

 

http://h30099.www3.hp.com/configurator/calc/Power%20Calculator

 

 

%20Catalog.xls

 

-Click on the system of interest. Example: DL380 G5

-Follow the instructions of the next screens.

Power Supply Output

Rated Steady-State Power

653.10W (at 100 VAC),

(per power supply)

 

653.08W (at 200 VAC)

System Inlet TemperatureOperating

50° to 95° F (10° to 35° C) at sea level with

 

 

an altitude derating of 1.8°F per every 1000 ft

 

 

(1.0°C per every 305 m) above sea level to a

 

 

maximum of 10,000 ft (3050 m), no direct

 

 

sustained sunlight. Maximum rate of change is

 

 

18°F/hr (10°C/hr). The upper limit may be

 

 

limited by the type and number of options

 

 

installed.

 

 

System performance may be reduced if

 

 

operating with a fan fault or above 86°F

 

 

(30°C).

 

Non-operating

40° to 140° F (-40° to 60° C)

 

 

Maximum rate of change is 36°F/hr

 

 

(20°C/hr).

Relative Humidity

Operating

10% to 85% relative humidity (Rh), 82.4°F

(non-condensing)

 

(28°C) maximum wet bulb temperature, non-

 

 

condensing.

 

Non-operating

10% to 95% relative humidity (Rh), 101.7°F

 

 

(38.7°C) maximum wet bulb temperature, non-

 

 

condensing.

Altitude

Operating

10,000 ft (3050 m). This value may be limited

 

 

by the type and number of options installed.

 

 

Maximum allowable altitude change rate is

 

 

1500 ft/min (457 m/min).

 

Non-operating

30,000 ft (9144 m). Maximum allowable

 

 

altitude change rate is 1500 ft/min (457

 

 

m/min).

Acoustic Noise

Listed are the declared A-Weighted sound power levels (LWAd) and

 

declared average bystander position A-Weighted sound pressure levels

 

(LpAm) when the product is operating in a 23°C ambient environment. Noise

 

emissions were measured in accordance with ISO 7779 (ECMA 74) and

 

declared in accordance with ISO 9296 (ECMA 109).

 

Idle

 

 

LWAd

6.86

 

LpAm

52.36dBA

 

Operating

 

 

LWAd

6.89

 

LpAm

52.60dBA

 

 

 

DA - 12913 Worldwide QuickSpecs — Version 1 — 2.11.2008

Page 20

Image 20
Contents QuickSpecs Have Vmfs QuickSpecs Shares are on a common volume the iSCSI snapshot limit is QuickSpecs AiO400r All-in-One Storage System AiO400r Storage Controller in the All-in-One Storage System QuickSpecs QuickSpecs QuickSpecs QuickSpecs QuickSpecs QuickSpecs AiO400r options SC44Ge HBADesired NC510C adapterAdd optional software NC510F adapterSAS/SATA 4-Port Cable SC11Xe HBA Add tape backup solution Specifications for recommended configurationsAdd HP CarePack services UH170PE20Catalog.xls QuickSpecs QuickSpecs