HP 400t manual 20Catalog.xls

Page 19

QuickSpecs

HP StorageWorks 400t and 400r All-in-One

Storage Systems

Technical Specifications

AiO400t

Additional Specifications

Dimensions (HxWxD)

14.5 x 6.9 x 16.8 in (36.7 x 17.5 x 42.6 cm)

(with feet)

 

 

Weight

Maximum

39 lb (17.5 kg)

(approximate)

(all hard drives, power

 

 

supplies, and processors

 

 

installed)

 

 

Minimum

23.81 lb (10.8 kg)

 

(one hard drive, power

 

 

supply, and processor

 

 

installed)

 

Input Requirements

Rated Line Voltage

90 to 132 VAC,

(per power supply)

 

180 to 264 VAC

 

Rated Input Current

6 A (at 100 VAC),

 

 

3 A (at 200 VAC)

 

Rated Input Frequency

47 to 63 Hz

 

Rated Input Power

600 W (at 100 VAC),

 

 

600 W (at 200 VAC)

Power Specifications

To review typical system power ratings use the Power Calculator which is

 

available via the online tool located at URL:

 

http://h30099.www3.hp.com/configurator/calc/Power%20Calculator

 

%20Catalog.xls

 

 

- Click on the system of interest. Example: DL380 G5

 

- Follow the instructions of the next screens.

Power Supply Output

Rated Steady-State Power

365 W (at 100 VAC),

(per power supply)

 

365 W (at 200 VAC)

 

Maximum Peak Power

385 W (at 100 VAC),

 

 

385 W (at 200 VAC)

System Inlet TemperatureOperating

10° to 35°C (50° to 95°F) at sea level with an

 

 

altitude derating of 1.0°C per every 305 m

 

 

(1.8°F per every 1000 ft) above sea level to a

 

 

maximum of 3050 m (10,000 ft), no direct

 

 

sustained sunlight. Maximum rate of change is

 

 

10°C/hr (18°F/hr). The upper limit may be

 

 

limited by the type and number of options

 

 

installed.

 

 

System performance may be reduced if

 

 

operating with a fan fault or above 30°C

 

 

(86°F).

 

Non-operating

-30° to 60°C (-22° to 140°F). Maximum rate of

 

 

change is 20°C/hr (36°F/hr).

Relative Humidity

Operating

10% to 90% relative humidity (Rh), 28°C

(non-condensing)

 

(82.4°F) maximum wet bulb temperature, non-

 

 

condensing.

 

Non-operating

5% to 95% relative humidity (Rh), 38.7°C

 

 

(101.7°F) maximum wet bulb temperature, non-

 

 

condensing.

Altitude

Operating

3050 m (10,000 ft). This value may be limited

 

 

by the type and number of options installed.

 

 

Maximum allowable altitude change rate is

 

 

457 m/min (1500 ft/min).

 

Non-operating

9144 m (30,000 ft). Maximum allowable

 

 

altitude change rate is 457 m/min (1500

 

 

ft/min).

AiO400R

Dimensions (HxWxD)

1.70 x 17.64 x 26.85 in (4.32 x 44.80 x 68.20 cm)

Additional

(with bezel)

 

Specifications

 

 

DA - 12913 Worldwide QuickSpecs — Version 1 — 2.11.2008

Page 19

Image 19
Contents QuickSpecs Have Vmfs QuickSpecs Shares are on a common volume the iSCSI snapshot limit is QuickSpecs AiO400r All-in-One Storage System AiO400r Storage Controller in the All-in-One Storage System QuickSpecs QuickSpecs QuickSpecs QuickSpecs QuickSpecs QuickSpecs NC510C adapter AiO400r optionsSC44Ge HBA DesiredSC11Xe HBA Add optional softwareNC510F adapter SAS/SATA 4-Port CableSpecifications for recommended configurations Add tape backup solutionUH170PE Add HP CarePack services20Catalog.xls QuickSpecs QuickSpecs