Installation Precautions:

Follow these precautions when installing the ProCurve NAC 800 appliance.

The rack or cabinet should be adequately secured to prevent it from becoming unstable and/or falling over.

Units installed in a rack or cabinet should be mounted as low as possible, with the heaviest devices at the bottom and progressively lighter devices installed above.

For safe operation, only install the unit horizontally, with the bottom side down.

Ensure the power source circuits are properly grounded, then use the power cord supplied with the unit to connect it to the power source.

If your installation requires a different power cord than the one supplied with the unit, be sure to use a power cord displaying the mark of the safety agency that defines the regulations for power cords in your country. The mark is your assurance that the power cord can be used safely with the unit.

When installing the unit, the AC outlet should be near the unit and should be easily accessible in case the unit must be powered off.

Ensure the unit does not overload the power circuits, wiring, and over- current protection. To determine the possibility of overloading the supply circuits, add together the ampere ratings of all devices installed on the same circuit as the ProCurve NAC unit and compare the total with the rating limit for the circuit. The maximum ampere ratings are usually printed on the devices near the AC power connectors.

Do not install the unit in an environment where the operating ambient temperature might exceed 40°C (104°F).

Ensure the air flow around the sides and back of the unit is not restricted.

Quick Install

2-3

Image 11
Contents Hardware Installation Guide ProCurve Network Access ControllerPublication Number Contents Recycle Statements Introduction ProCurve Network Access ControllerIntroduction ProCurve NAC 800 Endpoint Integrity SolutionInline 802.1XThis page intentionally left blank Quick Install Summary Quick InstallIncluded Parts Installation Precautions Hardware Specifications Prepare the Installation Site Installing the ApplianceRack Mounting the ProCurve NAC Mount the UnitProCurve NAC 800 rack mount example Horizontal Surface Mounting Connect the Unit to a Power SourceOptional Connect a Console to the Appliance Connect the Network CablesTerminal Configuration Initial Appliance Configuration To set the server IP Address Configuring via the Front LCD DisplayQuick Install Quick Install Quick Install This page intentionally left blank Safety Information Safety and EMC Regulatory StatementsTible de causer des dommages à léquipement Informations concernant la sécuritéGerät beschädigen kann Hinweise zur SicherheitAttrezzature Considerazioni sulla sicurezzaResultar en averías al equipo Consideraciones sobre seguridadSafety Information Japan Safety Information China Japan EMC Regulatory StatementsCanada Australia/New ZealandKorea Taiwan Safety and EMC Regulatory Statements Waste Electrical and Electronic Equipment Weee Statements Recycle StatementsRecycle Statements Recycle Statements Descarte de Lixo Elétrico na Comunidade Européia Numerics IndexPreparing the installation site … 2-5publication data … Rack This page intentionally left blank This page intentionally left blank This page intentionally left blank 5998-3237