RIELLO BURNER APPLICATION CHART

The optional F3 and F5 Riello flame retention oil burners have been UL listed (UL File #MP3252) for application on the following Thermo Pride oil fired furnaces.

MODEL

OH3

OC5, OL5,

OL11, OH11,

OL16, OH16,

OL20

PART

OH5, OT5

OT11

OT16

 

 

MTG. PLATE

TOP-25752

35750

35750

35750

35750

PART NO.

BTM-35733

 

 

 

 

 

 

 

 

 

 

 

MTG. PLATE

 

 

 

 

 

GASKET

330090

330088

330088

330088

330088

PART NO.

 

 

 

 

 

 

 

 

 

 

 

**NOZZLE

.50-60A

.60-60A*

.75-60A*

.90-60A*

1.10-60A*

SIZE

 

 

 

 

 

 

 

 

 

 

 

NOZZLE

380393

380394

380395

380396

380397

PART NO.

 

 

 

 

 

 

OIL PUMP

170 PSI

145 PSI

145PSI

145 PSI

150PSI

PRESSURE

 

 

 

 

 

 

 

 

 

 

 

BURNER

F3

F3

F5

F5

F5

 

 

 

 

 

 

BURNER

380215

380215

380216

380216

380216

PART NO.

 

 

 

 

 

 

 

 

 

 

 

*A refers to hollow pattern nozzle

**NOTE: The reason the Riello burner nozzle sizes are smaller than the standard Thermo Pride burner nozzles is that pre-set pump pressures are higher, therefore achieving the same firing rate with a smaller nozzle.

For more specific burner information, specifications or service information, reference the training manual enclosed

with each Riello burner or contact:Riello Corporation of America, 5 Pond Park Road

Hingham, Massachusetts 02043

(617)749-8292

I. HEAT EXCHANGER CLEANING INSTRUCTIONS:

?WARNING: THE HEAT EXCHANGER MUST BE CLEANED BY A QUALIFIED SERVICE PERSON.

It is important to inspect and clean the heat exchanger once a year, or as necessary, to remove any build-up of soot. A layer of soot on the inside of the heat exchanger will act as an insulator and reduce heat transfer, resulting in less efficiency.

To clean the heat exchanger, first turn off all power to the unit. Next, remove the access panel (see below and beginning of following page) immediately above the burner (on the horizontal furnace, it will be located to the side of the burner) to gain entry to the clean-out covers, refer to figure 15. This panel is identified with a label. Remove clean-out covers, the vent connector pipe to the chimney, the burner, and the burner mounting plates. When removing the clean-out covers, special care must be taken not to damage the gaskets. Should the gaskets separate, crack, break, or be unsuitable for reuse, the gasket must be replaced before reattaching the clean-out covers.

11

Image 15
Contents OIL Fired Furnace Safety Section ?WARNING and Cautions?CAUTION do not Attempt to Start the Burner When Page Section Table of Contents Beginning II. General Instructions Read Before Start of Installation Rotation of Front Flue Elbow Draft Regulators Trim CollarUnit DIA. Hole Flue DIA GasketAir filter mounting location for the OC2-5 furnace Filters Mounted External to the FurnaceTypical filter rack and dimensions for the highboy furnaces FAN and Limit Position and Location Burner InstallationTypical location of the overfire air tap TWO Piece Mounting PlateHorizontal Furnace Positions External Wire Harness Locations for OL33Thermo Pride Burner Applications Burner Specifications and ApplicationsOIL Nozzle Capacity Chart Heat Exchanger Cleaning Instructions Riello Burner Application ChartIII. Users Information Section Typical Heat Exchanger Cleanout Cover LocationsStarting the Burner Filter Cleaning and Location?CAUTION do not Attempt to Make Repairs Yourself Inspection AreasLocation of the air filters on a typical counterflow furnace Customer APPENDIX-A Replacement Parts List Page Page Page Page Page Page Page Page Page APPENDIX-B Wiring Diagrams

OC5-85, OC2-56, OL11-105, OL2-56, OL20-151 specifications

Thermo Products offers a range of advanced temperature control solutions tailored for various industrial applications. Among the lineup are the OC2-56, OH16-125, OL37-250, OH11-105, and OL16-125 models, each designed with cutting-edge technologies and unique characteristics that cater to diverse user needs.

The OC2-56 is a compact and efficient temperature controller that excels in providing precise thermal management. It features advanced PID control algorithms, ensuring stable temperature regulation, while its robust build guarantees durability in tough environments. The intuitive user interface enables effortless temperature adjustments, making it suitable for both novice and experienced users.

The OH16-125 model is specifically engineered for applications requiring high-temperature processing. With a maximum operational temperature of 125°C, this unit includes an innovative heat exchanger that enhances thermal efficiency. Its easy-to-read digital display provides real-time temperature feedback, and its compact footprint allows for space-saving installations in demanding environments.

Designed for maximum versatility, the OL37-250 is perfect for large-scale operations. It supports multiple heating elements and comes equipped with a powerful heating mechanism, capable of reaching temperatures up to 250°C. The unit's intelligent monitoring system ensures optimal performance, while its user-friendly interface simplifies setup and operation.

The OH11-105 offers a unique combination of performance and energy efficiency. With a maximum temperature of 105°C, this model is ideal for medium-sized applications where reliable heat delivery is essential. Its state-of-the-art insulation technology helps reduce heat loss, making it an environmentally friendly option. Additionally, the OH11-105 features integrated safety mechanisms, protecting both the unit and the user.

Lastly, the OL16-125 is designed to support a wide range of industrial processes. With programmable settings and an easy-to-navigate control panel, this unit allows users to set specific temperature profiles for different applications. Its sturdy construction and high safety ratings make it an ideal choice for rigorous environments.

Overall, Thermo Products' OC2-56, OH16-125, OL37-250, OH11-105, and OL16-125 models showcase a commitment to quality, reliability, and innovation in thermal management technology. Each model is crafted to meet the highest standards and cater to the diverse needs of various industries, ensuring optimal performance in every application.