QuickSpecs
HP ProLiant DL380 Generation 5
Memory
NOTE: Memory configurations listed do not apply to "Factory Integrated Models".
Standard Memory
2 GB
Upgrading Memory and Memory Interleaving
When upgrading memory, DIMMs 1A and 2A must match. DIMMs 3B and 4B, DIMMs 5C and 6C, and DIMMs 7D and 8D must match and must be installed as a pair. When DIMMs 1A and 2A are populated the system is automatically configured for 2:1 interleaving. When all 4 banks are populated the system is automatically configured for 4:1 interleaving. When four, six, or eight DIMMs are populated with identical DIMMs the system is automatically configured for bank interleaving.
Standard Memory Plus Optional Memory
Up to 14 GB memory is available with the standard memory of 2 GB and the optional installation
Standard Memory Replaced with Optional Memory
Up to 32 GB of memory is available with the removal of the standard 1 GB of memory and the optional installation of PC2- 5300 Fully Buffered DIMMs
NOTE: Chart does not represent all possible configurations.
Memory |
|
|
|
| Slot |
|
|
| ||
|
| 1 | 2 | 3 | 4 |
| 5 | 6 | 7 | 8 |
Standard | 2 GB | 1 GB | 1 GB | Empty | Empty |
| Empty | Empty | Empty | Empty |
Optional | 14 GB | 1 GB | 1 GB | 2 GB | 2 GB |
| 2 GB | 2 GB | 2 GB | 2 GB |
Maximum | 32 GB | 4 GB | 4 GB | 4 GB | 4 GB |
| 4 GB | 4 GB | 4 GB | 4 GB |
NOTE: In the online spare configuration, the ROM automatically configures the last populated bank as the spare memory. If only banks A and B are populated, bank B is the spare bank. If banks A, B, and C are populated, bank C is the spare bank, Online spare memory is configured through RBSU.
NOTE: Mirrored Memory uses mirrored banks to provide a high level of memory redundancy. Customer chooses to
implement or not: User selectable via BIOS and default is off.
Following are memory options available from HP: |
|
1 GB FBD | |
2 GB FBD | |
2 GB FBD | |
4 GB FBD | |
4 GB FBD | |
8 GB FBD | |
8 GB FBD |
NOTE: Memory Option Kits described as LP include Low Power DIMMs. For more information on ProLiant Energy Efficient
Features, please visit: http://h18004.www1.hp.com/products/servers/platforms/energyefficient/
In Advanced ECC mode, FBDIMMs must be populated as specified in the following table:
Configuration | Bank A | Bank B | Bank C | Bank D | |
1A and 3A | 5B and 7B | 2C and 4C | 6D and 8D | ||
| |||||
1 | X | - | - | - | |
2 | X | X | - | - | |
3 | X | X | X | - | |
4 | X | X | X | X |