HP BL30p Server Blades BL30p manual Required Network, 10Base-T Categories 3, 4 or 5 UTP 100 meters

Page 13

QuickSpecs

HP ProLiant BL30p Server Blade

Standard Features (Server Blade Enclosure and Interconnects)

ProLiant BL p-Class Fibre Fibre Channel signals travel from a HP ProLiant BL20p server blade series and/or HP ProLiant BL30p Channel pass through server blades series through the server blade enclosure backplane. Fibre Channel signals are terminated

through the RJ-45 Patch Panel 2 CGESM or GbE2 Interconnect Switch (with Storage Connectivity Kit) in the interconnect bays. To provide redundancy each server blade has two Fibre Channel signals; one Fibre Channel signal terminates through the right interconnect, the other Fibre Channel signal terminates through the left interconnect.

Eight Fibre Channel small form factor pluggable (SPF) transceiver cages exist on the front of each RJ-45 Patch Panel 2 and rear of each GbE2 Interconnect Switch (16 Fibre Channel connections per server blade enclosure). The SPF cages are used for insertion of SPF transceivers included with the HP ProLiant BL20p G2 Dual-port Fibre Channel Mezzanine Card and the HP ProLiant BL30p Dual-Port Fibre Channel Adapter.

Required Network

10Base-T

Categories 3, 4 or 5 UTP (100 meters)

Cabling

 

EIA/TIA-568 100-ohm STP (100 meters)

 

100Base-TX

Category 5 UTP (100 meters)

 

 

EIA/TIA-568 100-ohm STP (100 meters)

 

1000Base-T

Category 5 UTP (100 meters)

 

 

EIA/TIA-568 100-ohm STP (100 meters)

 

1000Base-SX

50/125 µm Multimode Fiber, 400 MHz/Km (500 meters)

 

 

50/125 µm Multimode Fiber, 500 MHz/Km (550 meters)

 

 

62.5/125 µm Multimode Fiber, 160 MHz/Km (220 meters)

 

 

62.5/125 µm Multimode Fiber, 200 MHz/Km (275 meters)

NOTE: For cabling information, refer to the website at: http://www.hp.com/go/servers/.

DA - 11958 Worldwide — Version 19 — August 15, 2005

Page 13

Image 13
Contents Maximum density HP ProLiant BL30p server blade OverviewHP BladeSystem p-Class Enhanced Server Blade Enclosures HP BladeSystem p-Class Power EnclosuresHP ProLiant BL30p Server Blade QuickSpecs Or Cgesm Interconnect Switch Mini bus bars OrorQuickSpecs QuickSpecs Standard Features Server Blade Fiber Channel on the HP ProLiant BL30p server blade No PCI slots, all features integratedLocal I/O Cable ProLiant BL p-Class Interconnect Switch Option Standard Features Server Blade Enclosure and InterconnectsEnclosure QuickSpecs ProLiant BL p-Class Cgesm or GbE2 switches blades seriesSupports a pair of two ProLiant BL p-Class RJ-45 Patch Panel10Base-T Categories 3, 4 or 5 UTP 100 meters Required NetworkCabling EIA/TIA-568 100-ohm STP 100 metersStandard Features Power System and Rack Information QuickSpecs Standard Features Manageability Essentials Value Packs Optional ProLiantSmartStart OS SupportQuickSpecs Security Availability FeaturesRack Airflow QuickSpecs Models ProLiant 3.2-GHz BL30p 1GB 1PProLiant 3.06-GHz BL30p Processors For 1GB Total Memory choose a or B ModelFor 2GB Total Memory choose two For 4GB Total MemoryUnique Options OptionsProLiant BL30p/BL35p AdapterQuickSpecs Enhanced Server 380625-B22Management Suite Blade EnclosuresHP BladeSystem p-Class Interconnects Power Options283192-B21 Two QuadT2 Interconnect ModulesSAN Switches HP BladeSystem Power Extension Kit 381686-B21Other Options Ultrium 460 technology Sdlt 600 technologyHP StorageWorks MSL5026S2 Tape Library HP StorageWorks MSL5052S2 Tape LibraryHP StorageWorks Virtual Library Systems HP StorageWorks EML E-Series Tape LibrariesHP StorageWorks 9.1 GB Mid-range Optical Jukeboxes HP StorageWorks 9.1 GB High-end Optical JukeboxesHP StorageWorks HP StorageWorks Ultra Density Optical StorageModular Smart Array 1000ProLiant Cluster Starter kit 364023-B21 Cluster OptionsUSB Options HP Rack 5000 SeriesHP Rack 10842 42U Shock Pallet 257415-B22 Rack 10000 SeriesRack Options for HP Service and SupportInstallation & Start-up Services Hardware Services On-site ServiceSoftware Operating Environment Care Packs HP ProLiant BL30p Server Blade all models Standard Memory MemoryStandard Memory Replaced with Optional Memory Memory Slot Standard 1024 MB OptionalInput Specifications HP BladeSystem p-Class DimensionsTemperature Range Wet Bulb TemperaturePower Requirements Technical SpecificationsBL p-Class GbE Weight Interconnect Switch Forwarding Mode MAC AddressesForwarding Table SafetyAge Time Memory ComplianceForwarding Mode BL p-Class GbE2 WeightPower RequirementsInterconnect Switch Weight Operating Single-Phase Model Performance Dimensions Requirements Temperature RangeWeights BladeSystemAmbient Temperature SpecificationsOutput Voltage Range See NoteSupported enclosures Dimensions Power Bus Box Mini Bus Bar Scalable Bus BarVoltage Max Total Power Max Current Per PowerRate Max Rated Power Specifications forOperating Voltage CurrentQuickSpecs