Overview
4.Select an Interconnect Kit. Each Interconnect Kit contains a pair of interconnects except the CGESM which includes a single interconnect switch. One interconnect kit is required with each server blade enclosure:
RJ-45 Patch Panel 2 with Fibre Channel pass through. This is the required patch panel model for Fibre Channel connectivity on HP ProLiant BL30p server blade (306465-B21).
Or
RJ-45 Patch Panel (230766-B21) Or
Quantity (2) Cisco Gigabit Switch Module for HP BladeSystem p-Class Interconnect Kit (with 16 10/100/1000 T/TX/T downlink ports, 2 RJ-45 10/100/1000 T/TX/T uplink ports, and 4 SFP ports) (378926-B21), with or without any combination of up to 4 10/100/1000 T/TX/T RJ-45 SFP Module (378928-B21) or 1000BASE SX Fiber SFP Module (378929-B21), with or without ProLiant BL p-Class Storage Connectivity Kit (with 16 Fibre Channel connectors) (321745 -B21) (required for ProLiant BLXXp server blade Fibre Channel connectivity when using the CGESM Interconnect Switch)
Or
Quantity (2) Cisco Gigabit Switch Module for HP BladeSystem p-Class Interconnect Kit (with 16 10/100/1000 T/TX/T downlink ports, 2 RJ-45 10/100/1000 T/TX/T uplink ports, and 4 SFP ports populated with (2) 10/100/1000 T/TX/T SFP modules) (378927-B21), with or without optional ProLiant BL p-Class Storage Connectivity Kit (with 16 Fibre Channel connectors) (321745 -B21) (required for ProLiant BLXXp server blade Fibre Channel connectivity when using the CGESM Interconnect Switch)
Or
BL p-Class C-GbE2 Interconnect Kit (with 16 10/100/1000 T/TX/T downlink ports, 6 RJ-45 10/100/1000 T/TX/T uplink ports ) (283192-B21), with or without optional ProLiant BL p-Class Storage Connectivity Kit (with 16 Fibre Channel connectors) (321745 -B21) (required for ProLiant BLXXp server blade Fibre Channel connectivity when using the GbE2 Interconnect Switch)
Or
BL p-Class F-GbE2 Interconnect (with 16 10/100/1000 T/TX/T downlink ports, 4 LC 1000 SX and 2 RJ-45 10/100/1000 T/TX/T uplink ports) (283193-B21), with or without optional ProLiant BL p-Class Storage Connectivity Kit (with 16 Fibre Channel connectors) (321745 -B21) (required for ProLiant BLXXp server blade Fibre Channel connectivity when using the GbE2 Interconnect Switch)
PLUS
5.Select HP BladeSystem p-Class power enclosure(s) and power supplies based on configuration.
NOTE: 3 phase power enclosure options are highly recommended for deployments of HP ProLiant BL30p server blades. Use the ProLiant BL p-Class sizing utility to help determine power configuration: http://h30099.www3.hp.com/configurator/calc/Power%20Calculator%20Catalog.xls .
NOTE: Power enclosures and supplies are not needed if using facility DC (-48V ± 10%).
Single phase 3U power enclosure with four power supplies (Single-phase 3U power enclosure holds a maximum of four power supplies) (NA/JPN- 239162-001) (INTL - 239162-421)
Or
Three-phase 3U power enclosure with six power supplies (Three-phase 3U power enclosure holds a maximum of six power supplies) (NA/JPN- 230769-001) (INTL - 230769-421)
(3U Power enclosures and supplies can also be purchased separately see options list) Or
1U power enclosure with six power supplies (378284-B21) Or
1U power enclosure with two power supplies (380314-B21)
(Additional power supplies can also be purchased separately - see options list)
PLUS
6.Select power distribution option (only required with 3U power enclosures): Mini bus bars (support up to 3 server blade enclosures) (240559-B21). NOTE: Two mini-bar configurations can be stacked to fill a 42U rack. Or
Scalable bus bars (support up to 5 server blade enclosures*) (240560-B21) Or