HP NC380T manual Specifications, UTP cable specifications

Page 11

Specifications

In this section

 

HP NC380T PCI Express Dual Port Multifunction Gigabit Server Adapter specifications

11

UTP cable specifications

11

RJ-45 pinouts and crossover function

12

HP NC380T PCI Express Dual Port Multifunction Gigabit Server Adapter specifications

Specification

Value

 

 

Network Controller Chipsets

Broadcom 5706C

 

 

Bus Type

PCI Express

 

 

Bus Width

Four lanes

 

 

Bus Speed

2.5 GHz

 

 

Data Transfer Method

Bus Master DMA

 

 

Power Requirement

Operating Voltage: +12V +/-8%

 

Power Consumption: 12.6 Watts

 

Maximum: 1.05A @ 12V (DC)

 

 

Standards Supported

IEEE 802.3ab, 802.3ad, 802.3u, 802.3x, 802.3, 802.1p, 802.1q

 

 

Dimensions

18.9 cm x 11.1 cm (without bracket) (7.44 x 4.37 inches (L x W))

 

 

Connector and Distances

Two RJ-45 Connectors, Cable and lengths as follows:

 

10BASE-T: Category 3, 4, or 5 UTP 100 Meters (328 feet)

 

100BASE-TX: Category 5 UTP 100 Meters (328 feet)

 

1000BASE-TX: Category 5 UTP 100 Meters (328 feet)

 

 

Interrupts Supported

Automatically configured

 

 

Temperature Range

Operating: 0°C to 55°C (32°F to 131°F)

 

Storage: -40°C to 85°C (-40°F to 185°F)

 

 

Relative Humidity (non-condensing)

Operating: 10% to 90%

 

Storage: 5% to 95%

 

 

Safety Compliance

CSA Mark (US and Canada)

 

CE Mark

 

EN 60590

 

 

UTP cable specifications

To connect to the network, the NC380T uses the following cable for 1000Base-T transmission:

Specifications 11

Image 11
Contents Part Number 404916-00B June 2007 Second Edition Audience assumptions Contents This section Technician notesHP contact information Where to go for additional helpOverview IntroductionLNK/ACT LED indicatorsUTP CAT5 cable Preventing electrostatic discharge Installing an adapterInstallation overview Connecting the network cable Installing an adapter in a serverUTP cable specifications SpecificationsRJ-45 pinouts and crossover function 10/100 pinouts using internal, straight-through crossoverRD+ TD+ BIDA+ BIDB+ BIDB- BIDA+ BIDD+ BIDD- BIDA- BIDC+ Bidc Specifications Class a equipment Regulatory compliance noticesRegulatory compliance identification numbers Federal Communications Commission noticeClass B equipment European Union regulatory notice ModificationsCables Canadian notice Avis CanadienJapanese notice Page Grounding methods to prevent electrostatic discharge Electrostatic dischargeIeee Acronyms and abbreviationsRSS Index