HP UX 11i v3 Interpreting Hardware Paths, Example 2-2 Hardware Path for a Private Loop Device

Page 18

Interpreting Hardware Paths

Examples 2-1 and 2-2 illustrate the Fibre Channel hardware path format:

Example 2-1 Hardware Path for a Direct Fabric Attach Device

Adapter Domain Area Port Bus Target LUN

0/1/2/0.1.19.255.0.0.0

Example 2-2 Hardware Path for a Private Loop Device

Adapter Domain Area Port Bus Target LUN

0/1/2/0.8.0.255.0.1.0

Table 2-3describes each field in the hardware path.

Table 2-3 Hardware Path Field Descriptions

Field

Value

Fibre Channel Topology of HBA

 

Fabric Topologies

Private Loop

 

 

Adapter

The hardware path of the Fibre Channel adapter through which the Logical Unit Number (LUN) is seen.

 

For multiport adapters, this field describes a specific port on the adapter.

Domain

Dependent on the Fibre

Typically the Domain ID of the switch to

8: HP-UX uses a Domain ID of 8 to

 

Channel topology of the

which the target device is attached, taken

indicate private loops. Fibre Channel

 

HBA.

from the most significant byte of the

switches seen by HP-UX hosts cannot

 

 

N_Port ID of the target device.

be configured with domain ID of 8.

Area

Depends on the Fibre

 

Channel topology of the

 

HBA.

Taken from the second byte of the N_Port 0 ID of the target device. On some switches, the second byte of the N_Port ID encodes the switch port to which the device is connected. The encoding method depends on the switch. See your switch manual to interpret this field.

Port

Depends on the Fibre

 

Channel topology of the

 

HBA and the target

 

device, and on the LUN

 

addressing method

 

used.

For LUNs with Peripheral Device Addressing, the value of this field is always

255.

For other LUN methods, the value of this

For other LUN methods, the value of

field is the least significant byte of the

this field is the Loop ID of the target

N_Port ID of the target device.

device.

Bus

Depends on the Fibre

 

Channel topology of the

 

HBA and the target

 

device, and on the LUN

 

addressing method

 

used.

For LUNs with Peripheral Device

For LUNs with Peripheral Device

Addressing, the value of this field is the

Addressing, the value of this field is

upper 4 bits of the least significant byte

the upper 4-bits of the Loop ID of the

of the N_Port ID of the target device.

target device.

For LUNs with Logical Unit Addressing, the value is the Bus Number field of the LUN. For LUNs with Volume Set Addressing (Flat Space Addressing), the value is bits 7 - 13 of the LUN.

18 Fibre Channel Adapter Installation

Image 18
Contents HP-UX 11i v2 and 11i Copyright 2008 Hewlett Packard Development Company L.P Table of Contents Technical Specifications List of Figures Page List of Tables Page List of Examples Page Adapter Overview HP Fibre Channel Mass Storage OverviewPage Prerequisites Fibre Channel Adapter InstallationInstalling Driver Software Fibre Channel Adapter Bundle and Product NamesInstalling Adapter Hardware Select Mark for Install from the Actions menuInstalling the Fibre Channel Adapter Cable Products Verifying the Fibre Channel Adapter InstallationAttaching the Adapter to Other Fibre Channel Devices Sample ioscan outputVerifying Connectivity # insf -e # ioscan -fExample 2-2 Hardware Path for a Private Loop Device Interpreting Hardware PathsExample 2-1 Hardware Path for a Direct Fabric Attach Device Hardware Path Field DescriptionsLUN Page Introduction Troubleshooting and MaintenanceObtaining Card Information after Installation Adapter LED StatesExample of Vital Product Data VPD after installation Example of ioscan entry after installationDevice HP MSA Volume HP Support Tools ManagerEvent Monitoring Service Fibre Channel Adapter MonitorSupported Products Offline Diagnostics Environment ODE Installing and Configuring Support Tools Manager and EMSDiagnostic Flowcharts Flowchart 1 Configuration TestFlowchart 1 Configuration Test Procedures Flowchart 2 Fibre Channel Connections Test Fibre Channel Connections TestFlowchart 2 Connections Test Procedures Firmware Updates Fibre Channel Host Bus Adapter Online Firmware UpdatesModifying the Scanning Policy Troubleshooting and Maintenance Regulatory Statements Regulatory StatementsCertification and Classification Information Laser Safety StatementsVcci Statement Japan Product InformationLaser Safety Finland Laserturvallisuus Laserturvallisuus Luokan 1 Laserlaite Klass 1 Laser ApparatPage Technical Specifications AD299A Technical SpecificationsTable B-1 AD355A Technical Specifications Table B-2Index