HP UX 11i v3 manual Flowchart 2 Connections Test Procedures

Page 29

Flowchart 2 Connections Test Procedures

The sections below provide additional detail on the procedures listed in Flowchart 2.

A.Verify that the Fibre Channel adapter is properly seated. Shut down the system by entering

/usr/sbin/shutdown -h.Power off the system and disconnect the cables. Check that the adapter is properly seated in the backplane. To verify that it is seated correctly, power on the system.

B.Adapter problem, call HP. Contact your HP service representative for assistance.

C.Verify that the connectors are solidly connected. Without powering off the system, make sure that the connectors on the fiberoptic cable match the keyed connectors on the adapter, and that they are solidly connected.

D.Verify the connection to the Fibre Channel Mass Storage device. Make sure the Fibre Channel cable is fully connected to the Fibre Channel Mass Storage device, and the device is operating. Follow the instructions in the device manual to check the device state. Try changing the connection to a different port on the Fibre Channel Mass Storage device, if possible. After checking the connections, go to Flowchart 3.

E.Verify that the Fibre Channel Mass Storage device is powered on. If not, power on the device.

F.Run Fibre Channel Mass Storage device-specific diagnostics. If diagnostics are available to troubleshoot the Fibre Channel Mass Storage device, follow the steps to verify that the device is functioning properly. After verification, go to Flowchart 3.

Figure 3-3 Flowchart 3: Boot Test

3

A

Is the

no

 

system bootable

 

 

over FC?

 

 

yes

 

B

Is

no

 

System Firm-

 

ware version

 

 

adequate?

 

 

yes

 

DIs

See the boot device in your system manual

C

Update firmware

13

Go to Flowchart 1

E

 

minimum ad-

no

 

apter ROM firmware

 

 

installed?

 

 

 

yes

 

 

 

 

F

 

 

 

Is

no

 

minimum ad-

 

apter EFI version

 

 

installed?

 

Update adapter

ROM firmware

G

Update adapter

EFI version

31

Go to Flowchart 1

31

Go to Flowchart 1

34 Go to Flowchart 2

Diagnostic Flowcharts

29

Image 29
Contents HP-UX 11i v2 and 11i Copyright 2008 Hewlett Packard Development Company L.P Table of Contents Technical Specifications List of Figures Page List of Tables Page List of Examples Page HP Fibre Channel Mass Storage Overview Adapter OverviewPage Installing Driver Software Fibre Channel Adapter InstallationPrerequisites Fibre Channel Adapter Bundle and Product NamesSelect Mark for Install from the Actions menu Installing Adapter HardwareInstalling the Fibre Channel Adapter Attaching the Adapter to Other Fibre Channel Devices Verifying the Fibre Channel Adapter InstallationCable Products Sample ioscan output# insf -e # ioscan -f Verifying ConnectivityExample 2-1 Hardware Path for a Direct Fabric Attach Device Interpreting Hardware PathsExample 2-2 Hardware Path for a Private Loop Device Hardware Path Field DescriptionsLUN Page Obtaining Card Information after Installation Troubleshooting and MaintenanceIntroduction Adapter LED StatesExample of ioscan entry after installation Example of Vital Product Data VPD after installationHP Support Tools Manager Device HP MSA VolumeSupported Products Event Monitoring ServiceFibre Channel Adapter Monitor Installing and Configuring Support Tools Manager and EMS Offline Diagnostics Environment ODEFlowchart 1 Configuration Test Diagnostic FlowchartsFlowchart 1 Configuration Test Procedures Fibre Channel Connections Test Flowchart 2 Fibre Channel Connections TestFlowchart 2 Connections Test Procedures Fibre Channel Host Bus Adapter Online Firmware Updates Firmware UpdatesModifying the Scanning Policy Troubleshooting and Maintenance Regulatory Statements Regulatory StatementsVcci Statement Japan Laser Safety StatementsCertification and Classification Information Product InformationLaserturvallisuus Luokan 1 Laserlaite Klass 1 Laser Apparat Laser Safety Finland LaserturvallisuusPage Table B-1 Technical SpecificationsAD299A Technical Specifications Table B-2 AD355A Technical SpecificationsIndex