Figure 3-2 Cables Installed

It is not normally necessary to dismantle or remove the bracket in order to perform any service operations on the blades enclosure, such as replacing InfiniBand switch modules. However, if you need to remove the bracket, use the following procedure:

1.Bring the cluster and the rack to a power-safe and stable state.

2.Disconnect all cables and secure them out of the work area, ensuring that the cables remain within their specified bend radius while they are not supported by the bracket.

3.Remove the two M6 screws that secure the bracket to the rack.

4.Unhook and remove the bracket from the rack columns.

8Installing and Using the Bracket

Image 8
Contents HP Cluster Platform Class Blade Cable Management Bracket Page Preparing for Installation Kit ContentsAudience Documentation ResourcesFasteners Required ResourcesPrerequisites Aligning the Bracket Bracket OrientationBracket Mount Locations Installing and Using the Bracket Cable ClipsCables Installed