Thermo Products CBD1-100N, CHB1-125N, CHB1-75N, CHB1-100N, CBD1-75N, CBD1-125N, CBD1-50N, CHB1-50N Iii

Page 4

All installations and services must be performed by qualified service personnel.

The following safety information should be read, understood, and followed by the installer.

1.Use only with type of gas approved for this furnace. Refer to furnace rating plate.

2.Connect this furnace to an approved vent system only. Combustion products must be carried outdoors. Refer to Section III, D thru H, of this manual.

The following pages contain various warnings and cautions found throughout the Thermo Pride Highboy and Dual Poise Condensing Gas Furnace Manual. Please read and comply with the statements below.

: This furnace is not to be used for temporary heating of buildings or structures under construction.

: These high efficiency condensing furnaces are not certified for and shall not be vented into a standard or any type of chimney.

: These furnaces may not be common vented with any other appliance.

: The vent and air intake elbows must be kept away from bushes, shrubs or any vegetation that may restrict the flow of flue products. It must also be kept clear of any leaves, weeds or other combustible materials. Keep the vent hood clear of snow. Avoid locating the terminals in areas where standing water or condensate drippage may be a problem.

: This CHB1/CDB1 furnace has been designed to be installed as a direct vent system. The failure to install the vent/air intake system as specified in these instructions will void the heat exchanger warranty and may result in property damage, personal injury or loss of life.

: Outside combustion air must not come from an area that is directly adjacent to a pool, hot tub or spa. Measures should be taken to prevent the entry of corrosive chemicals or vapors to the combustion and ventilation air supply. Such chemicals include but are not limited to chlorinated and/or fluorinated hydrocarbons such as found in refrigerants, aerosol propellants, dry cleaning fluids, degreasers and removers. Other harmful compounds may come from bleaches, air fresheners or mastics. Vapors from such products can form acid compounds when burned in a gas flame. Should acid compounds form in your furnace; it may reduce the life of the furnace.

: Because of the potential of odorant fade, a gas leak may not be detected by smell. If this furnace is installed below grade, contact your gas supplier for a gas detector.

: Turn off power to furnace before it is placed into service. The gas piping system must have been leak tested by a qualified heating contractor.

: It may be necessary to purge the air out of the gas line for initial start-up of the furnace after installation. This should be done by a qualified heating contractor. If excessive gas escapes when purging the gas supply at the union, allow the area to ventilate for at least 15 minutes before attempting to start the furnace. LP gas is especially dangerous because the specific gravity of LP gas allows it to accumulate at floor level at a dangerous concentration. For remainder of operating instructions, reference Users Information Manual.

: Heat exchanger oil will burn off on initial firing creating an unpleasant odor. To prevent this odor from occurring more than once, it is suggested that:

1.A window(s) be opened.

2.The thermostat set at highest setting.

3.The furnace remain running at conditions 1&2 for 30 minutes or until odor has dissipated.

iii

Image 4
Contents Condensing GAS Furnace Safety Information 390540 Iii Page Index Section Beginning II. Furnace Specifications CHB1 Series Model no BTU/HR InputBTU/HR Output HT. of CasingCDB1 Series Model no Installation Parts Packages CHB1-50/75 Description Quantity Installation Parts Packages CDB1-50/75 Description Quantity III. General Installation Codes and ClearancesFurnace Location B1. CDB1 Horizontal Application Page General Requirements For Venting Models CHB1 / CDB1 Not Permitted Direct Venting Through a Sidewall Page Page E1. Single-Pipe Sidewall Venting Option Optional Direct Vent Terminations Conentric Vent KIT Side Wall Vent KIT Required Exhaust Vent and Air Intake Piping for CHB1 Furnace Page Page Page Page Condensate Trap Assembly Mounted On the Model Series CHB1 Page Page General GAS Piping J1. Requirements and Sizing of Duct Work Page Page Filters CHB1 Models Highboys CDB1 Models CounterflowsUSE of NON-THERMO Pride Filter Retention Means CHB1,CDB1-50 CHB1,CDB1-75 CHB1,CDB1-100 CHB1,CDB1-125Electronic AIR Cleaner EAC and Humidifier Installation WiringThermostat Anticipator Setting Blower Motor Speed Wiring Blower Delay Settings Field Wiring and Replacing WiringCDB1 Series only Page Initial Start UP Adjustment of BTU Input RateOperating Instructions GAS Pressure Chart for ALL CHB1 Model Furnaces Burner AdjustmentFurnace Checkout Procedure Installers Instructions to User VI. Troubleshooting Diagnostic FeaturesRoom Temp Surface Diagnostic LED LAMP. Reset by AT the HOT Surface Time Delay For Proper Voltage SECONDS? Yes Appendix -A Replacement Parts List Page Page Page Appendix B Wiring Diagrams

CHB1-50N, CBD1-50N, CBD1-125N, CBD1-100N, CBD1-75N specifications

Thermo Products offers a range of high-performance heating and cooling solutions tailored to meet the demands of both residential and commercial applications. Among their innovative offerings are the CHB1-50N, CBD1-75N, CHB1-100N, CHB1-125N, and CBD1-100N models, which are designed to provide efficient temperature control while maximizing energy savings.

The CHB1 series, including the CHB1-50N, CHB1-100N, and CHB1-125N, features advanced heating technologies that allow for rapid heating response times. These units are equipped with high-efficiency heat exchangers that ensure optimal heat transfer with minimal energy consumption. A key characteristic of these models is their ability to operate quietly, making them ideal for settings where noise reduction is a priority.

In comparison, the CBD1 series, specifically the CBD1-75N and CBD1-100N, focuses on cooling capabilities that are equally impressive. These units utilize state-of-the-art cooling compressors designed to provide powerful cooling while maintaining low operational costs. The CBD1 models incorporate environmentally friendly refrigerants, ensuring compliance with the latest environmental regulations, which appeals to environmentally conscious customers.

All models in this lineup are designed with user friendliness in mind, featuring intuitive digital controls that allow for precise temperature adjustments. This makes them suitable for end users with varying levels of technical expertise. Additionally, the units support smart home integration, enabling remote monitoring and control via mobile apps, which enhances comfort and convenience for users.

Durability is another hallmark of Thermo Products. The robust construction of both the CHB1 and CBD1 series units ensures resilience against harsh weather conditions and prolonged usage. Furthermore, they come equipped with advanced safety features, including over-temperature protection and automatic shut-off mechanisms, which provide peace of mind for consumers.

In summary, the Thermo Products CHB1-50N, CBD1-75N, CHB1-100N, CHB1-125N, and CBD1-100N models represent a comprehensive solution for effective heating and cooling needs. With their blend of efficiency, innovative technologies, user-friendly design, and durability, these products are positioned to deliver exceptional value and performance in a variety of environments.