HP Modular Cooling System manual Description Spare part Customer self repair Number

Page 17

Item

Description

Spare part

Customer self repair

 

 

number

 

 

 

 

 

5

SPS-CONTROL, WATER, GRP, MCS-G2

463359-001

Optional2

6

SPS-FAN, MAIN, MCS-G2

463362-001

Optional2

7

SPS-CONTROLLER, FAN, MCS-G2

468279-001

Optional2

8

SPS-AIR BLEEDER, MCS-G2

463367-001

Optional2

9

SPS-DISPLAY, OPERATOR, MCS-G2

463355-001

Optional2

10

SPS-MANAGEMENT MODULE, MCS-G2

463357-001

Optional2

11

SPS-TRANSFER SWITCH, AC, MCS-G2

463358-001

Optional2

12

SPS-WHOLE MCS UNIT, MCS-G2

463356-001

Optional2

SPS-KIT, DOOR RELEASE

463365-001

Optional2

SPS-HOOKUP KIT MCS G2**

611040-001

Optional2

*

SPS-ELECTRICAL HOOKUP, MCS-G2***

463369-001

Optional2

*Not shown

**The Main hose kit contains the hardware required to repair the main hoses. For more information, see the HP Modular Cooling System Hook-Up Kit Installation Instructions.

***The Electrical kit contains replacement power and network cables.

1Mandatory—Parts for which customer self repair is mandatory. If you request HP to replace these parts, you will be charged for the travel and labor costs of this service.

2Optional—Parts for which customer self repair is optional. These parts are also designed for customer self repair. If, however, you require that HP replace them for you, there may or may not be additional charges, depending on the type of warranty service designated for your product.

3No—Some HP parts are not designed for customer self repair. In order to satisfy the customer warranty, HP requires that an authorized service provider replace the part. These parts are identified as "No" in the Illustrated Parts Catalog.

1Mandatory: Obligatoire—Pièces pour lesquelles la réparation par le client est obligatoire. Si vous demandez à HP de remplacer ces pièces, les coûts de déplacement et main d'œuvre du service vous seront facturés.

2Optional: Facultatif—Pièces pour lesquelles la réparation par le client est facultative. Ces pièces sont également conçues pour permettre au client d'effectuer lui-même la réparation. Toutefois, si vous demandez à HP de remplacer ces pièces, l'intervention peut ou non vous être facturée, selon le type de garantie applicable à votre produit.

3No: Non—Certaines pièces HP ne sont pas conçues pour permettre au client d'effectuer lui-même la réparation. Pour que la garantie puisse s'appliquer, HP exige que le remplacement de la pièce soit effectué par un Mainteneur Agréé. Ces pièces sont identifiées par la mention “Non” dans le Catalogue illustré.

1Mandatory: Obbligatorie—Parti che devono essere necessariamente riparate dal cliente. Se il cliente ne affida la riparazione ad HP, deve sostenere le spese di spedizione e di manodopera per il servizio.

2Optional: Opzionali—Parti la cui riparazione da parte del cliente è facoltativa. Si tratta comunque di componenti progettati per questo scopo. Se tuttavia il cliente ne richiede la sostituzione ad HP, potrebbe dover sostenere spese addizionali a seconda del tipo di garanzia previsto per il prodotto.

3No: Non CSR—Alcuni componenti HP non sono progettati per la riparazione da parte del cliente. Per rispettare la garanzia, HP richiede che queste parti siano sostituite da un centro di assistenza autorizzato. Tali parti sono identificate da un “No” nel Catalogo illustrato dei componenti.

1Mandatory: Zwingend—Teile, die im Rahmen des Customer Self Repair Programms ersetzt werden müssen. Wenn Sie diese Teile von HP ersetzen lassen, werden Ihnen die Versand- und Arbeitskosten für diesen Service berechnet. 2Optional: Optional—Teile, für die das Customer Self Repair-Verfahren optional ist. Diese Teile sind auch für Customer Self Repair ausgelegt. Wenn Sie jedoch den Austausch dieser Teile von HP vornehmen lassen möchten, können bei diesem Service je nach den für Ihr Produkt vorgesehenen Garantiebedingungen zusätzliche Kosten anfallen.

Illustrated parts catalog 17

Image 17
Contents HP Modular Cooling System G2 Maintenance and Service Guide Intended audience Contents Troubleshooting Réparation par le client CSR Parts only warranty serviceCustomer self repair Riparazione da parte del cliente Service de garantie pièces seulesServizio di garanzia per i soli componenti Reparaciones del propio cliente Servicio de garantía exclusivo de componentes Reparo feito pelo cliente Garantieservice Parts OnlyServiço de garantia apenas para peças Customer self repair Customer self repair Customer self repair Customer self repair Replaceable spare parts Illustrated parts catalogDescription Spare part Customer self repair Number Page Illustrated parts catalog Spare replacement tips Removal and replacement proceduresSpare replacement video OverviewComponent location Callout Component Required toolsPreparation procedures Safety considerationsDisconnecting the power Rack warnings and cautionsDraining water from the MCS G2 unit Turning off the waterRemoving the AC transfer switch AC transfer switchReplacing the AC transfer switch Removing the air bleeder valve Air bleeder valveReplacing the air bleeder valve Bottom fan unitReplacing the bottom fan unit Removing the bottom fan unitRemoving the condensation pump Condensation pumpRemoval and replacement procedures Replacing the condensation pump Removal and replacement procedures Removing the fan controller Fan controllerReplacing the fan controller Removing the fan unit Fan unitReplacing the fan unit Removing the flow meter sensor Flow meter sensorRemoval and replacement procedures Replacing the flow meter sensor Removal and replacement procedures Removal and replacement procedures Removal and replacement procedures Removing the front automatic door release Front automatic door releaseReplacing the front automatic door release Removing the management module Management moduleRemoval and replacement procedures Replacing the management module Removing the operator display Operator displayRemoval and replacement procedures Replacing the operator display Removal and replacement procedures Rear automatic door release Removing the rear automatic door release Replacing the rear automatic door release Removal and replacement procedures Removing the water controller Water controllerRemoval and replacement procedures Replacing the water controller Removal and replacement procedures Removing the water level sensors Water level sensorsReplacing the water level sensors Removal and replacement procedures Removal and replacement procedures Removing the water valve Water valveRemoval and replacement procedures Removal and replacement procedures Removal and replacement procedures Replacing the water valve Removal and replacement procedures Removal and replacement procedures Removal and replacement procedures Reconnecting the power Operation checklistReconnecting the main water hoses Restoring water flow Maintenance and service MaintenanceWater quality requirements and specifications Air and water heat exchanger maintenanceFrost damage Water precautionsPlumbing materials to avoid Diagnostic toolsCondensation management HP Modular Cooling System troubleshooting TroubleshootingMCS specifications SpecificationsThermal and air flow performance HP 10642 G2 Rack specificationsEnvironmental specifications Acronyms and abbreviations Index Index
Related manuals
Manual 10 pages 27.17 Kb Manual 84 pages 16.27 Kb Manual 93 pages 20.21 Kb Manual 4 pages 15.71 Kb Manual 16 pages 5.24 Kb Manual 60 pages 37.09 Kb

Modular Cooling System specifications

The HP Modular Cooling System (MCS) is a state-of-the-art solution designed to efficiently manage the heat generated by high-density IT environments. As data centers face the ever-increasing demand for processing power, traditional cooling methods often fall short, leading to inefficiencies and raised energy costs. The HP MCS addresses this issue with a scalable, flexible design that optimizes cooling performance while minimizing energy consumption.

One of the main features of the HP Modular Cooling System is its modular architecture, which allows for easy expansion and customization based on the specific needs of a data center. This scalability means that as a facility grows or changes, the cooling system can be modified without the need for extensive renovations or replacements. The MCS can be installed in various configurations, further enhancing its versatility.

The technology behind the HP MCS includes advanced cooling methods such as direct evaporative cooling and chilled water cooling. Direct evaporative cooling utilizes the principles of evaporative heat exchange to cool air without excessive energy consumption, making it an eco-friendly choice. In contrast, chilled water cooling uses a network of pipes filled with chilled water to remove heat from the server environment efficiently. This combination allows the MCS to adapt to various heat loads and ambient conditions.

Another notable characteristic of the HP Modular Cooling System is its intelligent controls and sensors. These components continually monitor temperature and humidity levels within the data center, automatically adjusting cooling output to maintain optimal conditions. This proactive approach helps to prevent overheating, reduces energy usage, and ensures the longevity of IT equipment.

Energy efficiency is further enhanced through the MCS's integration with HP's monitoring and management software. This software analyzes cooling performance trends, providing actionable insights for facility managers, enabling them to make informed decisions regarding cooling strategies. Additionally, the system is designed with environmentally sustainable practices in mind, aligning with global initiatives to reduce carbon footprints and promote green technology.

The HP Modular Cooling System stands out for its combination of innovative technologies, flexibility, and a commitment to energy efficiency. As data centers continue to evolve, the MCS remains a crucial asset in the pursuit of optimized performance and sustainability, providing a reliable solution to meet the demanding cooling needs of modern IT infrastructure.