HP products are designed with many Customer Self Repair (CSR) parts to minimize repair time and allow for greater flexibility in performing defective parts replacement. If during the diagnosis period HP (or HP service providers or service partners) identifies that the repair can be accomplished by the use of a CSR part, HP will ship that part directly to you for replacement. There are two categories of CSR parts:

Mandatory—Parts for which customer self repair is mandatory. If you request HP to replace these parts, you will be charged for the travel and labor costs of this service.

Optional—Parts for which customer self repair is optional. These parts are also designed for customer self repair. If, however, you require that HP replace them for you, there may or may not be additional charges, depending on the type of warranty service designated for your product.

NOTE: Some HP parts are not designed for customer self repair. In order to satisfy the customer warranty, HP requires that an authorized service provider replace the part. These parts are identified as "No" in the Illustrated Parts Catalog.

Based on availability and where geography permits, CSR parts will be shipped for next business day delivery. Same day or four-hour delivery may be offered at an additional charge where geography permits. If assistance is required, you can call the HP Technical Support Center and a technician will help you over the telephone. HP specifies in the materials shipped with a replacement CSR part whether a defective part must be returned to HP. In cases where it is required to return the defective part to HP, you must ship the defective part back to HP within a defined period of time, normally five (5) business days. The defective part must be returned with the associated documentation in the provided shipping material. Failure to return the defective part may result in HP billing you for the replacement. With a customer self repair, HP will pay all shipping and part return costs and determine the courier/carrier to be used.

For more information about HP's Customer Self Repair program, contact your local service provider. For the North American program, refer to the HP website (http://www.hp.com/go/selfrepair).

Parts only warranty service

Your HP Limited Warranty may include a parts only warranty service. Under the terms of parts only warranty service, HP will provide replacement parts free of charge.

For parts only warranty service, CSR part replacement is mandatory. If you request HP to replace these parts, you will be charged for the travel and labor costs of this service.

Réparation par le client (CSR)

Les produits HP comportent de nombreuses pièces CSR (Customer Self Repair = réparation par le client) afin de minimiser les délais de réparation et faciliter le remplacement des pièces défectueuses. Si pendant la période de diagnostic, HP (ou ses partenaires ou mainteneurs agréés) détermine que la réparation peut être effectuée à l'aide d'une pièce CSR, HP vous l'envoie directement. Il existe deux catégories de pièces CSR:

Customer self repair 5

Image 5
Contents HP Modular Cooling System G2 Maintenance and Service Guide Intended audience Contents Troubleshooting Réparation par le client CSR Parts only warranty serviceCustomer self repair Riparazione da parte del cliente Service de garantie pièces seulesServizio di garanzia per i soli componenti Reparaciones del propio cliente Servicio de garantía exclusivo de componentes Reparo feito pelo cliente Garantieservice Parts OnlyServiço de garantia apenas para peças Customer self repair Customer self repair Customer self repair Customer self repair Replaceable spare parts Illustrated parts catalogDescription Spare part Customer self repair Number Page Illustrated parts catalog Spare replacement tips Removal and replacement proceduresSpare replacement video OverviewComponent location Callout Component Required toolsPreparation procedures Safety considerationsDisconnecting the power Rack warnings and cautionsDraining water from the MCS G2 unit Turning off the waterRemoving the AC transfer switch AC transfer switchReplacing the AC transfer switch Removing the air bleeder valve Air bleeder valveReplacing the air bleeder valve Bottom fan unitReplacing the bottom fan unit Removing the bottom fan unitRemoving the condensation pump Condensation pumpRemoval and replacement procedures Replacing the condensation pump Removal and replacement procedures Removing the fan controller Fan controllerReplacing the fan controller Removing the fan unit Fan unitReplacing the fan unit Removing the flow meter sensor Flow meter sensorRemoval and replacement procedures Replacing the flow meter sensor Removal and replacement procedures Removal and replacement procedures Removal and replacement procedures Removing the front automatic door release Front automatic door releaseReplacing the front automatic door release Removing the management module Management moduleRemoval and replacement procedures Replacing the management module Removing the operator display Operator displayRemoval and replacement procedures Replacing the operator display Removal and replacement procedures Rear automatic door release Removing the rear automatic door release Replacing the rear automatic door release Removal and replacement procedures Removing the water controller Water controllerRemoval and replacement procedures Replacing the water controller Removal and replacement procedures Removing the water level sensors Water level sensorsReplacing the water level sensors Removal and replacement procedures Removal and replacement procedures Removing the water valve Water valveRemoval and replacement procedures Removal and replacement procedures Removal and replacement procedures Replacing the water valve Removal and replacement procedures Removal and replacement procedures Removal and replacement procedures Reconnecting the power Operation checklistReconnecting the main water hoses Restoring water flow Maintenance and service MaintenanceWater quality requirements and specifications Air and water heat exchanger maintenanceFrost damage Water precautionsPlumbing materials to avoid Diagnostic toolsCondensation management HP Modular Cooling System troubleshooting TroubleshootingMCS specifications SpecificationsThermal and air flow performance HP 10642 G2 Rack specificationsEnvironmental specifications Acronyms and abbreviations Index Index
Related manuals
Manual 10 pages 27.17 Kb Manual 84 pages 16.27 Kb Manual 93 pages 20.21 Kb Manual 4 pages 15.71 Kb Manual 16 pages 5.24 Kb Manual 60 pages 37.09 Kb

Modular Cooling System specifications

The HP Modular Cooling System (MCS) is a state-of-the-art solution designed to efficiently manage the heat generated by high-density IT environments. As data centers face the ever-increasing demand for processing power, traditional cooling methods often fall short, leading to inefficiencies and raised energy costs. The HP MCS addresses this issue with a scalable, flexible design that optimizes cooling performance while minimizing energy consumption.

One of the main features of the HP Modular Cooling System is its modular architecture, which allows for easy expansion and customization based on the specific needs of a data center. This scalability means that as a facility grows or changes, the cooling system can be modified without the need for extensive renovations or replacements. The MCS can be installed in various configurations, further enhancing its versatility.

The technology behind the HP MCS includes advanced cooling methods such as direct evaporative cooling and chilled water cooling. Direct evaporative cooling utilizes the principles of evaporative heat exchange to cool air without excessive energy consumption, making it an eco-friendly choice. In contrast, chilled water cooling uses a network of pipes filled with chilled water to remove heat from the server environment efficiently. This combination allows the MCS to adapt to various heat loads and ambient conditions.

Another notable characteristic of the HP Modular Cooling System is its intelligent controls and sensors. These components continually monitor temperature and humidity levels within the data center, automatically adjusting cooling output to maintain optimal conditions. This proactive approach helps to prevent overheating, reduces energy usage, and ensures the longevity of IT equipment.

Energy efficiency is further enhanced through the MCS's integration with HP's monitoring and management software. This software analyzes cooling performance trends, providing actionable insights for facility managers, enabling them to make informed decisions regarding cooling strategies. Additionally, the system is designed with environmentally sustainable practices in mind, aligning with global initiatives to reduce carbon footprints and promote green technology.

The HP Modular Cooling System stands out for its combination of innovative technologies, flexibility, and a commitment to energy efficiency. As data centers continue to evolve, the MCS remains a crucial asset in the pursuit of optimized performance and sustainability, providing a reliable solution to meet the demanding cooling needs of modern IT infrastructure.