SPX Cooling Technologies SS-NC-08A Convenience and Safety Options Guardrail and Ladder

Page 11

Marley / NC Class Stainless CoolingTower / Specifications: Options

11

 

Specifications

Convenience and Safety Options

Guardrail and Ladder:

11.2Add the following paragraph in the Access section: The top of the tower shall be equipped with a sturdy guardrail, complete with kneerail and toeboard, designed according to OSHA guidelines and factory welded into subassemblies for ease of field instal- lation. Posts, toprails and kneerails shall be 38mm square tubing. The guardrail assembly shall be hot dipped galvanized after welding and capable of withstanding a 890N concentrated live load in any direction. Posts shall be spaced on centers of 2.4m or less. A 46cm wide aluminum ladder with 76mm I-beam side rails and 32mm diameter rungs shall be permanently attached to the endwall casing of the tower, rising from the base of the tower to the top of the guardrail.

Ladder Extension:

11.2Add the following to the end of the above paragraph: Provide a ladder extension for connection to the foot of the ladder attached to the tower casing. This extension shall be long enough to rise from the roof (grade) level to the base of the tower. The installing contractor shall be respon- sible for cutting the ladder to length; attaching it to the foot of the tower lad- der; and anchoring it at its base.

Ladder Safety Cage:

11.3Add the following paragraph in the Access section: A heavy gauge galva- nized steel safety cage shall surround the ladder, extending from a point approximately 2m above the foot of the ladder to the top of the guardrail.

Ladder Safety Gate:

10.3Add the following paragraph in the Access section: A galvanized steel, self-closing gate shall be provided at the guardrail level of the ladder.

Specification Value

The NC Class cooling tower has been designed to minimize the need for mainte-

nance personnel to get on top of the tower to perform maintenance and inspections.

For the comfort and safety of your operat- ing personnel, we recommend that you specify a ladder and guardrail—and that you require it of all bidders! Although not required for safe operation by OSHA many user's own safety rules may dictate these options.

Outside the tower, stainless steel guardrail

material is not normally considered necessary. If you air quality is sufficiently poor to warrant stainless steel, change the specifica- tion wording accordingly.

Many towers are installed such that the base of the tower is 61cm or more above the roof or grade level. This makes it difficult to get up to the foot of the attached ladder. The ladder extension alleviates this problem. Marley ladder extensions are available in standard 1.5m and 3.3m lengths.

To meet OSHA guidelines, towers whose fan decks are 6m or more above roof or grade, and which are equipped with lad- ders, should have safety cages surrounding the ladders, but with approximately 2m clear headroom.

Outside the tower, stainless steel safety cage material is not normally considered necessary. If you air quality is sufficiently poor to warrant stainless steel, change the specification wording accordingly.

A galvanized self-closing gate located at the guardrail level of the fan deck, exterior motor access platform and access door platform. Stainless steel is available with the stainless guardrail option.

Image 11
Contents Marley NC Class Stainless Crossflow Cooling Tower Marley / NC Class Stainless CoolingTower / Contents Marley / NC Class Stainless CoolingTower Base Specifications Specification ValueDesign Loading WarrantyThermal Performance and Efficiency Construction Mechanical Equipment SpecificationsFill, Louvers and Drift Eliminators Casing, Fan Deck and Fan Guard Hot Water Distribution SystemCold Water Collection Basin AccessLadder Extension Convenience and Safety Options Guardrail and LadderLadder Safety Cage Ladder Safety GateGuardrail Ladder Extension Interior Mechanical Equipment Access Door PlatformPlenum Walkway Control Options Electric Water Level Control Vibration Limit SwitchBasin Heater Specifications Specification Value Marley Premium VFD System Fan Cylinder Extensions Miscellaneous Options Motor out of the AirstreamInlet Sound Attenuation Inlet Flow Control ValvesEqualizer Flume Weir Gates Sound ControlLow Noise Fan Outlet Sound AttenuationHigh Wind Load/Seismic Designs Ultra Low-Noise FanSingle Hot Water Inlet Connection per Cell Air Inlet ScreensExtended Geareducer Lube Line with Dipstick Multicell Basin Equalizer OutletsBasin Sweeper Piping Page Worcester WR3 8AB United Kingdom

SS-NC-08A specifications

The SPX Cooling Technologies SS-NC-08A is a cutting-edge, open-circuit cooling tower designed for a variety of industrial applications. Renowned for its efficiency and durability, the SS-NC-08A exemplifies modern engineering innovations, catering to facilities that require reliable temperature regulation while minimizing water usage.

One of the standout features of the SS-NC-08A is its superior thermal performance. Equipped with advanced fill media, this closed cooling tower optimizes heat transfer, allowing for enhanced cooling capacity in a compact footprint. This makes it an excellent choice for industries such as power generation, petrochemical processes, and manufacturing, where maintaining strict temperature control is essential.

In addition to its thermal performance, the SS-NC-08A is designed with energy efficiency in mind. Featuring a low-sound fan design, this unit minimizes operational noise, making it suitable for urban installations or environments where noise pollution is a concern. The axial fan technology used in the SS-NC-08A is not only energy-efficient but also capable of achieving high airflows with lower energy consumption compared to conventional fan designs.

The SS-NC-08A also integrates advanced corrosion-resistant coatings to prolong its lifecycle and minimize maintenance needs. This characteristic is particularly important for facilities operating in harsh environments with exposure to chemicals or brine solutions. The unit's robust construction ensures it can withstand the challenges of demanding applications, reducing downtime and repair costs.

Another key characteristic of the SS-NC-08A is its modular design. This allows for easy installation, maintenance, and scalability. Whether expanding a facility or replacing older systems, the modular nature of the SS-NC-08A streamlines the process. Additionally, it incorporates a simplified water distribution system that enhances water flow and distribution across the fill.

In conclusion, the SPX Cooling Technologies SS-NC-08A cooling tower stands as a reliable, efficient, and durable solution for various industrial cooling needs. With its advanced thermal performance, energy efficiency, corrosion resistance, and modular design, it addresses the requirements of today’s modern industries, ensuring optimal performance and longevity. This makes it an excellent investment for organizations aiming to maintain efficient operations while adhering to environmental sustainability goals.