SPX Cooling Technologies SS-NC-08A specifications Marley / NC Class Stainless CoolingTower

Page 3

Marley / NC Class Stainless CoolingTower /

3

 

NC Class Stainless Steel towers are factory assembled, crossflow cooling towers, designed to serve air conditioning and refrigeration systems as well as light to medium industrial process loads on clean water. They evolve from a factory-assembled concept of towers pioneered by Marley some 50 years ago, and incorporate all of the design advancements that our customers have found valuable. The NC Class has been designed specifically for sound control and tonnage density and represents the current state of the art in this cooling tower category.

This booklet not only relates the language to use in describing an appropriate NC Class cooling tower— but also defines why certain items and features are important enough to specify with the intention of insisting upon compliance by all bidders. The left-hand column of pages 4 thru 22 provides appropriate text for the various specification paragraphs, whereas the right hand column comments on the meaning of the subject matter and explains its value.

Pages 4 thru 10 indicate those paragraphs which will result in the purchase of a basic cooling tower—one that accomplishes the specified thermal performance, but which will lack many operation—and maintenance- enhancing accessories and features that are usually desired by those persons who are responsible for the continued and continuing operation of the system of which the tower is part. It will also incorporate those standard materials which testing and experience has proven to provide acceptable longevity in normal operating conditions.

Pages 11 thru 22 provide paragraphs intended to add those features, components and materials that will customize the tower to meet the user's requirements.

Space does not permit definition and explanation of all of the possible options that can be applied to the NC Class. We realize that you, the purchaser, must be happy with the tower's characteristics, and we are prepared to provide—or provide for—any reasonable enhancement that you are willing to define and purchase. Your needs will become part of the continuing evolution of this Marley product line.

Image 3
Contents Marley NC Class Stainless Crossflow Cooling Tower Marley / NC Class Stainless CoolingTower / Contents Marley / NC Class Stainless CoolingTower Base Specifications Specification ValueWarranty Thermal Performance and EfficiencyDesign Loading Construction Mechanical Equipment SpecificationsFill, Louvers and Drift Eliminators Casing, Fan Deck and Fan Guard Hot Water Distribution SystemCold Water Collection Basin AccessLadder Extension Convenience and Safety Options Guardrail and LadderLadder Safety Cage Ladder Safety GateGuardrail Ladder Extension Access Door Platform Plenum WalkwayInterior Mechanical Equipment Control Options Vibration Limit Switch Basin HeaterElectric Water Level Control Specifications Specification Value Marley Premium VFD System Fan Cylinder Extensions Miscellaneous Options Motor out of the AirstreamInlet Sound Attenuation Inlet Flow Control ValvesEqualizer Flume Weir Gates Sound ControlLow Noise Fan Outlet Sound AttenuationHigh Wind Load/Seismic Designs Ultra Low-Noise FanSingle Hot Water Inlet Connection per Cell Air Inlet ScreensMulticell Basin Equalizer Outlets Basin Sweeper PipingExtended Geareducer Lube Line with Dipstick Page Worcester WR3 8AB United Kingdom

SS-NC-08A specifications

The SPX Cooling Technologies SS-NC-08A is a cutting-edge, open-circuit cooling tower designed for a variety of industrial applications. Renowned for its efficiency and durability, the SS-NC-08A exemplifies modern engineering innovations, catering to facilities that require reliable temperature regulation while minimizing water usage.

One of the standout features of the SS-NC-08A is its superior thermal performance. Equipped with advanced fill media, this closed cooling tower optimizes heat transfer, allowing for enhanced cooling capacity in a compact footprint. This makes it an excellent choice for industries such as power generation, petrochemical processes, and manufacturing, where maintaining strict temperature control is essential.

In addition to its thermal performance, the SS-NC-08A is designed with energy efficiency in mind. Featuring a low-sound fan design, this unit minimizes operational noise, making it suitable for urban installations or environments where noise pollution is a concern. The axial fan technology used in the SS-NC-08A is not only energy-efficient but also capable of achieving high airflows with lower energy consumption compared to conventional fan designs.

The SS-NC-08A also integrates advanced corrosion-resistant coatings to prolong its lifecycle and minimize maintenance needs. This characteristic is particularly important for facilities operating in harsh environments with exposure to chemicals or brine solutions. The unit's robust construction ensures it can withstand the challenges of demanding applications, reducing downtime and repair costs.

Another key characteristic of the SS-NC-08A is its modular design. This allows for easy installation, maintenance, and scalability. Whether expanding a facility or replacing older systems, the modular nature of the SS-NC-08A streamlines the process. Additionally, it incorporates a simplified water distribution system that enhances water flow and distribution across the fill.

In conclusion, the SPX Cooling Technologies SS-NC-08A cooling tower stands as a reliable, efficient, and durable solution for various industrial cooling needs. With its advanced thermal performance, energy efficiency, corrosion resistance, and modular design, it addresses the requirements of today’s modern industries, ensuring optimal performance and longevity. This makes it an excellent investment for organizations aiming to maintain efficient operations while adhering to environmental sustainability goals.