Fan Motor Starter Control Panel:

6.4Add the following paragraph in the Mechanical Equipment sec- tion: Each cell of the cooling tower shall be equipped with a UL listed control system in a IP14 or IP56 out- door enclosure capable of controlling single-speed or two-speed motors as required, and designed specifically for cooling tower applications. The panel shall include a main fused disconnect or main circuit breaker with an external operating handle, lockable in the off position for safety. Across-the-line mag- netic starters or solid-statesoft-start starters as required shall be controlled with a thermostatic or solid-state temperature controller. Door mounted selector switches shall be provided to enable automatic or manual control and wired for 240VAC control. Control circuit to be wired out to terminal blocks for field connection to a remote vibration switch, overload trip alarms and remote temperature control devic- es. The temperature controller shall be adjustable for the required cold-water temperature. If a thermostatic control- ler is used it shall be mounted on the side of the tower with the temperature sensing bulb installed in the cold water basin using a suspension mounting bracket. If a solid-state temperature controller is used the controller will be door mounted on the control panel. The temperature controller will display two temperatures, one for outgoing water and the other for set point. Water temperature input shall be obtained using a three-wire RTD with dry well in the outlet water piping and wired back to the solid-state tempera- ture controller in the control panel.

Specification Value

If it is your opinion that the control system for the cooling tower be part of the tower manufacturer’s responsibility, we are in wholehearted agreement with you. Who better to determine the most efficient mode and manner of a cooling tower’s operation— and to apply a system most compatible with it—than the design- er and manufacturer of the cooling tower?

Marley variable speed drives are also available for the ultimate in temperature control, energy management and mechanical equip- ment longevity. See specifications on page 16.

Image 14
Contents Marley NC Class Stainless Crossflow Cooling Tower Marley / NC Class Stainless CoolingTower / Contents Marley / NC Class Stainless CoolingTower Specifications Specification Value BaseDesign Loading WarrantyThermal Performance and Efficiency Construction Specifications Mechanical EquipmentFill, Louvers and Drift Eliminators Hot Water Distribution System Casing, Fan Deck and Fan GuardAccess Cold Water Collection BasinLadder Safety Gate Convenience and Safety Options Guardrail and LadderLadder Safety Cage Ladder ExtensionGuardrail Ladder Extension Interior Mechanical Equipment Access Door PlatformPlenum Walkway Control Options Electric Water Level Control Vibration Limit SwitchBasin Heater Specifications Specification Value Marley Premium VFD System Miscellaneous Options Motor out of the Airstream Fan Cylinder ExtensionsSound Control Inlet Flow Control ValvesEqualizer Flume Weir Gates Inlet Sound AttenuationOutlet Sound Attenuation Low Noise FanAir Inlet Screens Ultra Low-Noise FanSingle Hot Water Inlet Connection per Cell High Wind Load/Seismic DesignsExtended Geareducer Lube Line with Dipstick Multicell Basin Equalizer OutletsBasin Sweeper Piping Page Worcester WR3 8AB United Kingdom

SS-NC-08A specifications

The SPX Cooling Technologies SS-NC-08A is a cutting-edge, open-circuit cooling tower designed for a variety of industrial applications. Renowned for its efficiency and durability, the SS-NC-08A exemplifies modern engineering innovations, catering to facilities that require reliable temperature regulation while minimizing water usage.

One of the standout features of the SS-NC-08A is its superior thermal performance. Equipped with advanced fill media, this closed cooling tower optimizes heat transfer, allowing for enhanced cooling capacity in a compact footprint. This makes it an excellent choice for industries such as power generation, petrochemical processes, and manufacturing, where maintaining strict temperature control is essential.

In addition to its thermal performance, the SS-NC-08A is designed with energy efficiency in mind. Featuring a low-sound fan design, this unit minimizes operational noise, making it suitable for urban installations or environments where noise pollution is a concern. The axial fan technology used in the SS-NC-08A is not only energy-efficient but also capable of achieving high airflows with lower energy consumption compared to conventional fan designs.

The SS-NC-08A also integrates advanced corrosion-resistant coatings to prolong its lifecycle and minimize maintenance needs. This characteristic is particularly important for facilities operating in harsh environments with exposure to chemicals or brine solutions. The unit's robust construction ensures it can withstand the challenges of demanding applications, reducing downtime and repair costs.

Another key characteristic of the SS-NC-08A is its modular design. This allows for easy installation, maintenance, and scalability. Whether expanding a facility or replacing older systems, the modular nature of the SS-NC-08A streamlines the process. Additionally, it incorporates a simplified water distribution system that enhances water flow and distribution across the fill.

In conclusion, the SPX Cooling Technologies SS-NC-08A cooling tower stands as a reliable, efficient, and durable solution for various industrial cooling needs. With its advanced thermal performance, energy efficiency, corrosion resistance, and modular design, it addresses the requirements of today’s modern industries, ensuring optimal performance and longevity. This makes it an excellent investment for organizations aiming to maintain efficient operations while adhering to environmental sustainability goals.