SPX Cooling Technologies Marley MD specifications MD5010PAC1L

Page 11

Marley / MD CoolingTower / Engineering Data : Schematic

11

 

 

 

 

 

 

 

 

MD5010 SINGLE CELL

 

 

 

 

 

 

 

 

 

 

 

 

 

dBA

 

Dimensions

Design

Shipping Weight

Model

Nominal Tons

Motor

 

Operating

 

kg

1.5m from air

 

 

 

 

note 2

note 3

kW

 

 

 

Weight

 

 

Heaviest

inlet face

H

 

A

Weight/Cell

 

 

 

 

 

kg

 

Section

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MD5010PAC1L

248

11

81

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MD5010PLC1L

249

11

80

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MD5010QAC1L

269

15

81

3412

 

2299

3883

2079

 

1052

 

 

 

 

 

 

MD5010QLC1L

270

15

80

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MD5010RAC1L

286

18.5

81

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MD5010RLC1L

289

18.5

80

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MD5010PAD1L

279

11

81

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MD5010PLD1L

280

11

80

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MD5010QAD1L

304

15

81

3717

 

2604

4046

2242

 

1190

 

 

 

 

 

 

MD5010QLD1L

305

15

80

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MD5010RAD1L

325

18.5

81

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MD5010RLD1L

329

18.5

80

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MD5010PAF1L

293

11

81

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MD5010PLF1L

294

11

80

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MD5010QAF1L

317

15

81

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MD5010QLF1L

318

15

80

4021

 

2909

4234

2430

 

1353

 

 

 

 

 

 

MD5010RAF1L

341

18.5

81

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MD5010RLF1L

346

18.5

80

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MD5010SAF1L

360

22

81

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MD5010SLF1L

362

22

81

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTE

1Use this bulletin for preliminary layouts only. Obtain current drawings from your Marley sales representative. All table data is per cell.

2Last two characters of the model number indicate number of cells and cell configuration.

3Nominal tons are based upon 35°C HW, 29.5°C CW, 25.5°C WB and .68 m3/hr per ton. The Marley UPDATE web-based selection software provides MD model recommendations based on specific design requirements.

4Standard overflow is a 3" dia. M connection located on the side of the collection basin. Makeup water connection is 2" dia. M connection located on the side of the tower. A 3" M drain connection is located on the side of the collection basin.

Image 11
Contents Marley MD Cooling Tower Page Marley / MD CoolingTower / Table of Contents Marley / MD CoolingTower Marley / MD CoolingTower END Elevation Marley / MD CoolingTower / Engineering Data SchematicPlan Side Elevation MD5008 Single CellDBA Dimensions 2371 MD5008 MulticellSide Elevation MD5008MAC2L 569 140 MD5010 Single Cell3651 MD5010PAC1L 3651 3715 MD5010 MulticellMD5010PAC2L 153 Side Elevation MD5016 Single Cell3607 Model Nominal Tons Motor Operating MD5016 TWO or Three Cell MD5016PAC2L MD5016 Four or More Cells DBA Dimensions Design Shipping Weight Model MD5016 Four Cell Quad MD5016PAC4B View a Marley / MD CoolingTower / Engineering Data SupportSupporting Steel Single Cell Supporting Steel Multicell CL Anchor BoltSump Section SIDE-OUTLET Suction ConnectionEND-OUTLET Suction Connection 70 MAX Marley / MD CoolingTower / Engineering Data HoistingIndoor Storage Tank Electric Basin HeatersWater Treatment Marley / MD CoolingTower / Engineering Data Water QualityBlowdown Thermal Performance Marley / MD CoolingTower / Specifications BasePerformance Warranty BaseMechanical Equipment Design LoadingConstruction Marley / MD CoolingTower / Specifications Base Casing and Fan Guard Fill, Louvers and Drift EliminatorsHot Water Distribution System Cold Water Collection Basin AccessWarranty Specifications Specification Value Marley / MD CoolingTower / Specifications OptionsConvenience and Safety Options Mechanical Access Platform Mechanical Equipment sec Control OptionsVibration Limit Switch Specifications Premium Efficiency Motor Miscellaneous Options Equalizer Flume Weir GatesSound Control Gregorys Bank Worcester WR3 8AB United Kingdom

Marley MD specifications

SPX Cooling Technologies has long been recognized as a leader in the cooling systems industry, and the Marley MD series exemplifies this commitment to innovation and efficiency. The Marley MD line is engineered for performance and versatility, ideal for a wide range of industrial and commercial cooling applications.

One of the defining features of the Marley MD is its advanced, modular design. This modular approach allows for easy scalability, enabling users to customize their cooling solution based on specific operational needs. Each unit can be configured to meet varying cooling loads, making the Marley MD suitable for both small and large facilities.

The Marley MD utilizes state-of-the-art materials, promoting durability and longevity. Constructed with corrosion-resistant components, these units are designed to withstand harsh environmental conditions, ensuring reliable operation over extended periods. The casing often features a combination of high-quality steel and advanced coatings that provide protection against the elements, which is especially important for outdoor installation.

Additionally, the Marley MD incorporates innovative technologies such as drift eliminators and splash bars, which significantly enhance water efficiency. These features minimize water loss and reduce the risk of contaminants entering the cooling system, leading to better overall performance. The design is also optimized for low sound levels, making these systems suitable for use in sensitive environments where noise reduction is a priority.

Energy efficiency is a critical characteristic of the Marley MD. It leverages advanced fan technology and airflow management to enhance cooling performance while minimizing energy consumption. By using high-efficiency motors and variable-speed drives, the Marley MD can operate at optimal levels under varying load conditions, resulting in significant energy savings over traditional cooling systems.

Another vital aspect is the ease of maintenance. The Marley MD is designed for straightforward access, allowing for efficient servicing and reducing downtime during maintenance activities. Features like removable panels and accessible components ensure that technicians can perform routine checks and repairs quickly and efficiently.

In conclusion, the Marley MD by SPX Cooling Technologies stands out due to its modular design, durable construction, advanced water management technologies, energy efficiency, and ease of maintenance. These characteristics make it an excellent choice for any facility looking to optimize its cooling operations while ensuring reliable and sustainable performance.