SPX Cooling Technologies Marley MD Fill, Louvers and Drift Eliminators, Casing and Fan Guard

Page 31

Marley / MD CoolingTower / Specifications: Base

Specifications

Specification Value

7.0Fill, Louvers and Drift Eliminators:

31

7.1

Fill shall be cross-corrugated,

Fill modules can be removed for inspection and cleaning in accor-

 

counterflow film type, thermoformed

dance with local anti legioinella guidelines.

 

from 0.40mm thick PVC. Fill shall

Drift rate varies with design water loading and air rate, as well as

 

be assembled into packs for ease of

 

removal and cleaning. Fill shall be sup-

drift eliminator depth and number of directional changes. The indi-

 

ported on channel sections supported

cated rate of 0.001% is easily achievable without premium cost. If a

 

from the tower structure and have a

lower rate is required, please discuss with your Marley sales repre-

 

flame spread rating less than 25. Drift

sentative.

 

eliminators shall be PVC with a mini-

 

 

mum of three changes in air direction,

 

 

and shall limit drift losses to no more

 

 

than 0.001% of the design water flow

 

 

rate.

 

7.2Air inlet louvers shall be a minimum of

127mm air travel, triple pass PVC to prevent water splashout and eliminate sunlight from entering the collection basin. For ease of service and long life of louvers, PVC louvers shall be enclosed in a removable frame that attaches to the air inlet without tools. Louvers with less than three changes in air direction are unacceptable.

8.0Hot Water Distribution System:

8.1

A pressured spray system shall dis-

The combination of PVC piping and polypropylene nozzles is very

 

tribute water evenly over the fill. The

resistant to the build-up of scale and slime.

 

branch arms shall be corrosion resis-

 

 

tant PVC with polypropylene spray noz-

 

 

zles attached to the branch arms with

 

 

a rubber socket connection for ease of

 

 

removal and cleaning. To ensure proper

 

 

spray system operation, nozzles shall

 

 

seat in branch arms without regard for

 

 

direction or alignment.

 

9.0Casing and Fan Guard:

9.1The casing shall be heavy gauge EN10142:2000 grade Z600 galvanized steel and shall be capable of with- standing the loads described in para- graph 4.1. Casing panels shall encase the fill on all four sides of the tower. The top of the fan cylinder shall be equipped with a conical, non-sagging, removable fan guard, fabricated of welded 5/16" and 7 gauge rods, and hot dip galvanized after fabrication.

Image 31
Contents Marley MD Cooling Tower Page Marley / MD CoolingTower / Table of Contents Marley / MD CoolingTower Marley / MD CoolingTower END Elevation Marley / MD CoolingTower / Engineering Data SchematicPlan Side Elevation MD5008 Single CellDBA Dimensions Side Elevation MD5008 Multicell2371 MD5008MAC2L 3651 MD5010 Single Cell569 140 MD5010PAC1L 3651 3715 MD5010 MulticellMD5010PAC2L 3607 Side Elevation MD5016 Single Cell153 Model Nominal Tons Motor Operating MD5016 TWO or Three Cell MD5016PAC2L MD5016 Four or More Cells DBA Dimensions Design Shipping Weight Model MD5016 Four Cell Quad MD5016PAC4B Supporting Steel Single Cell Marley / MD CoolingTower / Engineering Data SupportView a Supporting Steel Multicell CL Anchor BoltEND-OUTLET Suction Connection SIDE-OUTLET Suction ConnectionSump Section 70 MAX Marley / MD CoolingTower / Engineering Data HoistingIndoor Storage Tank Electric Basin HeatersBlowdown Marley / MD CoolingTower / Engineering Data Water QualityWater Treatment Thermal Performance Marley / MD CoolingTower / Specifications BasePerformance Warranty BaseConstruction Design LoadingMechanical Equipment Marley / MD CoolingTower / Specifications Base Hot Water Distribution System Fill, Louvers and Drift EliminatorsCasing and Fan Guard Warranty AccessCold Water Collection Basin Specifications Specification Value Marley / MD CoolingTower / Specifications OptionsConvenience and Safety Options Mechanical Access Platform Mechanical Equipment sec Control OptionsVibration Limit Switch Specifications Premium Efficiency Motor Miscellaneous Options Equalizer Flume Weir GatesSound Control Gregorys Bank Worcester WR3 8AB United Kingdom

Marley MD specifications

SPX Cooling Technologies has long been recognized as a leader in the cooling systems industry, and the Marley MD series exemplifies this commitment to innovation and efficiency. The Marley MD line is engineered for performance and versatility, ideal for a wide range of industrial and commercial cooling applications.

One of the defining features of the Marley MD is its advanced, modular design. This modular approach allows for easy scalability, enabling users to customize their cooling solution based on specific operational needs. Each unit can be configured to meet varying cooling loads, making the Marley MD suitable for both small and large facilities.

The Marley MD utilizes state-of-the-art materials, promoting durability and longevity. Constructed with corrosion-resistant components, these units are designed to withstand harsh environmental conditions, ensuring reliable operation over extended periods. The casing often features a combination of high-quality steel and advanced coatings that provide protection against the elements, which is especially important for outdoor installation.

Additionally, the Marley MD incorporates innovative technologies such as drift eliminators and splash bars, which significantly enhance water efficiency. These features minimize water loss and reduce the risk of contaminants entering the cooling system, leading to better overall performance. The design is also optimized for low sound levels, making these systems suitable for use in sensitive environments where noise reduction is a priority.

Energy efficiency is a critical characteristic of the Marley MD. It leverages advanced fan technology and airflow management to enhance cooling performance while minimizing energy consumption. By using high-efficiency motors and variable-speed drives, the Marley MD can operate at optimal levels under varying load conditions, resulting in significant energy savings over traditional cooling systems.

Another vital aspect is the ease of maintenance. The Marley MD is designed for straightforward access, allowing for efficient servicing and reducing downtime during maintenance activities. Features like removable panels and accessible components ensure that technicians can perform routine checks and repairs quickly and efficiently.

In conclusion, the Marley MD by SPX Cooling Technologies stands out due to its modular design, durable construction, advanced water management technologies, energy efficiency, and ease of maintenance. These characteristics make it an excellent choice for any facility looking to optimize its cooling operations while ensuring reliable and sustainable performance.