SPX Cooling Technologies Marley MD specifications Miscellaneous Options Equalizer Flume Weir Gates

Page 38

Marley / MD CoolingTower / Specifications: Options

Specifications

Specification Value

38

start and stop control, bypass/VFD selec- tion, Auto/Manual selections, manual speed control. To prevent heating prob- lems in the cooling tower fan motor and to assure proper gear reducer lubrication the VFD system shall de energize the motor once 25% motor speed is reached and cooling is no longer required. The cooling tower manufacturer shall supply VFD start-up assistance. Tower vibration testing throughout the speed range is required to identify and lockout any natu- ral frequency vibration levels which may exceed CTI guidelines.

Miscellaneous Options

Equalizer Flume Weir Gates:

11.2Add the following paragraph under Cold Water Collection Basin: The interconnecting flume between cells shall be equipped with a removable cover plate to permit the shutdown of one cell for maintenance purposes, or to permit independent cell operation.

Premium Efficiency Motor

6.3Replace paragraph 6.3 with the fol- lowing: The complete mechanical equipment assembly for each cell shall be supported by a rigid, hot-dip galvanized steel structural support that resists misalignment between the motor and sheaves (pulleys). For belt- drive towers with motors inside the airstream, motors shall be mounted on an adjustable base that swivels outside the access door for maintenance. For belt-drive towers with motors mounted outside the airstream, a protective cover shall be mounted over the motor and sheave to protect it from the weather and prevent inadvertent con- tact. The mechanical equipment assem- bly shall be warranted against any fail- ure caused by defects in materials and workmanship for no less than five (5) years following the date of tower ship- ment. This warranty shall cover the fan, speed reducer, motor, drive shaft and couplings, and the mechanical equip- ment support. The bearing assemblies and V-belts shall be warranted for 18 months.

Where it is your intention to be able to operate both cells of the tower while the flume cover plate is installed, separate outlet connections, float valves and overflows must be provided for each cell. Likewise, this would require separate sensors and controls for basin heater systems, if installed.

IEC premium efficiency motor with a five year warranty enhances the standard five year mechanical equipment warranty of the MD cooling tower.

Image 38
Contents Marley MD Cooling Tower Page Marley / MD CoolingTower / Table of Contents Marley / MD CoolingTower Marley / MD CoolingTower Side Elevation MD5008 Single Cell Marley / MD CoolingTower / Engineering Data SchematicPlan END ElevationDBA Dimensions 2371 MD5008 MulticellSide Elevation MD5008MAC2L 569 140 MD5010 Single Cell3651 MD5010PAC1L MD5010 Multicell 3651 3715MD5010PAC2L 153 Side Elevation MD5016 Single Cell3607 Model Nominal Tons Motor Operating MD5016 TWO or Three Cell MD5016PAC2L MD5016 Four or More Cells DBA Dimensions Design Shipping Weight Model MD5016 Four Cell Quad MD5016PAC4B View a Marley / MD CoolingTower / Engineering Data SupportSupporting Steel Single Cell CL Anchor Bolt Supporting Steel MulticellSump Section SIDE-OUTLET Suction ConnectionEND-OUTLET Suction Connection Marley / MD CoolingTower / Engineering Data Hoisting 70 MAXElectric Basin Heaters Indoor Storage TankWater Treatment Marley / MD CoolingTower / Engineering Data Water QualityBlowdown Base Marley / MD CoolingTower / Specifications BasePerformance Warranty Thermal PerformanceMechanical Equipment Design LoadingConstruction Marley / MD CoolingTower / Specifications Base Casing and Fan Guard Fill, Louvers and Drift EliminatorsHot Water Distribution System Cold Water Collection Basin AccessWarranty Marley / MD CoolingTower / Specifications Options Specifications Specification ValueConvenience and Safety Options Mechanical Access Platform Control Options Mechanical Equipment secVibration Limit Switch Specifications Miscellaneous Options Equalizer Flume Weir Gates Premium Efficiency MotorSound Control Gregorys Bank Worcester WR3 8AB United Kingdom

Marley MD specifications

SPX Cooling Technologies has long been recognized as a leader in the cooling systems industry, and the Marley MD series exemplifies this commitment to innovation and efficiency. The Marley MD line is engineered for performance and versatility, ideal for a wide range of industrial and commercial cooling applications.

One of the defining features of the Marley MD is its advanced, modular design. This modular approach allows for easy scalability, enabling users to customize their cooling solution based on specific operational needs. Each unit can be configured to meet varying cooling loads, making the Marley MD suitable for both small and large facilities.

The Marley MD utilizes state-of-the-art materials, promoting durability and longevity. Constructed with corrosion-resistant components, these units are designed to withstand harsh environmental conditions, ensuring reliable operation over extended periods. The casing often features a combination of high-quality steel and advanced coatings that provide protection against the elements, which is especially important for outdoor installation.

Additionally, the Marley MD incorporates innovative technologies such as drift eliminators and splash bars, which significantly enhance water efficiency. These features minimize water loss and reduce the risk of contaminants entering the cooling system, leading to better overall performance. The design is also optimized for low sound levels, making these systems suitable for use in sensitive environments where noise reduction is a priority.

Energy efficiency is a critical characteristic of the Marley MD. It leverages advanced fan technology and airflow management to enhance cooling performance while minimizing energy consumption. By using high-efficiency motors and variable-speed drives, the Marley MD can operate at optimal levels under varying load conditions, resulting in significant energy savings over traditional cooling systems.

Another vital aspect is the ease of maintenance. The Marley MD is designed for straightforward access, allowing for efficient servicing and reducing downtime during maintenance activities. Features like removable panels and accessible components ensure that technicians can perform routine checks and repairs quickly and efficiently.

In conclusion, the Marley MD by SPX Cooling Technologies stands out due to its modular design, durable construction, advanced water management technologies, energy efficiency, and ease of maintenance. These characteristics make it an excellent choice for any facility looking to optimize its cooling operations while ensuring reliable and sustainable performance.