Page 29

CAUTION: Do not use this utility if there are any IO Accelerator devices installed in the system that are not selected to be cleared or purged of data.

Ensure that you back up any data prior to activation of this utility.

Remove any devices that are not targeted for purge.

After the data is removed from the target devices, it is purged.

There is no recovery to this action.

CAUTION: If the device is in Read-only mode, perform a format using fio-formatbefore running fio-sure-erase.

The fio-sure-eraseutility cannot erase the device if it is in Minimal mode. Updating the firmware might move the device out of Minimal Mode. If the device remains in Minimal mode, contact HP Support (http://www.hp.com/support) for assistance.

IMPORTANT: Prior to reactivating the device, format the device with fio-formatafter running fio-sure-erase.

To run fio-sure-erase, the block device must be detached. For more information, see "fio-detach(on page 24)."

Description

The fio-sure-eraseis a command-line utility that securely removes data from IO Accelerator devices. It complies with the Clear and Purge level of destruction from the following standards:

DOD 5220.22-M—Complies with instructions for Flash EPROM.

NIST SP800-88—Complies with instructions for Flash EPROM.

For more information, see the following sections on "Clear support" and "Purge support."

Syntax

fio-sure-erase [options] <device>

where <device> is the name of the device node (/dev/fctx), where x indicates the card number: 0, 1, 2, and so on. For example, /dev/fct0 indicates the first IO Accelerator device installed on the system. To view this device node, use "fio-status(on page 26)."

 

IMPORTANT: Products with Multiple Devices

 

fio-sure-eraseapplies to individual IO Accelerator devices. For example, if you are

 

planning to purge an ioDrive Duo device, perform this operation on each of the two IO

 

Accelerator devices.

 

 

 

 

 

 

 

Options

 

Description

 

 

 

 

 

-p

 

Purge instead of Clear: performs a write followed by an erase. For more information,

 

 

 

see "Purge support."

 

-y

 

No confirmation: Does not require a yes/no response to execute the utility.

 

-q

 

Quiet: Does not display the status bar.

 

 

 

 

IMPORTANT: If fio-sure-eraseis run without options, then a Clear is performed. For more

 

information, see "Clear support."

 

 

 

 

Each block of memory consists of uniform 1 bits or 0 bits.

Utilities 29

Image 29
Contents HP IO Accelerator 3.2.3 Solaris User Guide Page Contents Upgrading devices About this guide Contents summaryProduct naming IntroductionOverview IO Accelerator capacity 320GB 640GB Models AJ878B BK836A Performance attributesSupported firmware revisions Required operating environmentIntroduction Introduction Installing the software and utilities Software installationInstallation overview Upgrading the firmware Loading the IO Accelerator VSL facility driver$ pfexec remdrv iomemory-vsl Dev/rdsk/c*d0p0Configuring a ZFS pool Enabling PCIe powerUsing the device as a swap Maintenance tools MaintenanceCommand-line utilities Enabling PCIe power overrideEnabling the override parameter Unmanaged shutdown issues Uninstalling IO Accelerator VSL and utilitiesOptions iomemory-vsl externalpoweroverride=value Disabling auto attach$ pfexec remdrv iomemo Disabling the IO Accelerator VSLEnabling the IO Accelerator VSL Management tools Monitoring and managing devicesIntroduction to monitoring and managing devices Example conditions to monitor Device LED indicators Introduction to performance and tuning Performance and tuningDisabling Dvfs Limiting Apci C-statesUtilities reference UtilitiesFio-attach Fio-attach device optionsFio-bugreport Fio-beaconFio-beacon device options Tmp/fio-bugreport-20100121.173256-sdv9ko.tar.bz2Fio-detach Fio-format options device Fio-formatFio-detach device options Fio-status device options Fio-statusFfield Fio-sure-erase Fio-sure-erase options device Fio-update-iodrive Fio-update-iodrive options iodriveversion.fff Domainbusslot.func Health metrics Monitoring IO Accelerator healthNand flash and component failure Health monitoring techniques Esxcfg-module --server server-name iomemory-vsl -g Using module parametersZFS pools and health monitoring Upgrading devices for IO Accelerator VSL 2.x.x to Upgrade procedureUpgrading devices $ modprobe iomemory-vsl Upgrading devices For more information Subscription serviceResources Before you contact HP Support and other resourcesHP contact information Customer Self RepairRéparation par le client CSR Riparazione da parte del cliente Reparaciones del propio cliente Reparo feito pelo cliente Support and other resources Support and other resources Support and other resources Acronyms and abbreviations Documentation feedback Index Index