Roberts Gorden TF-250, TF-350, TF-300, TF-120, TF-200, TF-160, TF-380 service manual

Page 68
Image 68
Contents Installer OwnerPage Roberts-Gordon LLC Page Table of Figures Page Heater Safety Manpower RequirementsSafety Labels and Their Placement California PropositionTop and Bottom Panel Label Placement Side Panel Label Placement National Standards and Applicable Codes Installer ResponsibilityWall Tag Maintain clearances to combustibles at all times for safety Clearances are the required distances thatStandard Reflector ONE Side Reflector45 Tilt Reflector Inches UnapprovedVented Inches CentimetersUnvented National Standards and Applicable Codes Major Components Contents of Core and Extension Packages Standard Parts ListContents of Burner Carton Component Package Guide Aluminum Reflector10 Typ Suggested LayoutsTF-380 4 Elbow Design Common Vent Elbow Burner Tube Individual Vent TF-160 Single Elbow Design Individual VentsHeater Installation On Page 17, FigureTypical Suspension Details Linear Heater Assembly Overview Linear Heater Layout Overview 60 18 m Tube Length Each Side Burner Tube Installation Burner InstallationTube Clamp Package Installation Coupling and Tube AssemblyOpen Closed1 Coupling and Tube Assembly Correct slide bar Incorrect slide bar Dimensions PositionTurbulator Installation Burner Hanger Burner Tube Reflector 1 Reflector, U-Clip and Reflector Support Installation Description Part Number Reflector Support PackageOptional Heater Accessories Tube Heater Assembly Overview Tube, Standard Tube, OppositeTube Heater Layout Overview 70 21 m Tube Length** Each Side 3 Reflector Joint Installation Elbow Package Configuration 1 Elbow Installation2 Elbow Installation 4 Reflector Joint Installation 5 Reflector Joint Detail Reflector Joint DetailReflector Side Extension 1 Bracket Installation 2 Side Reflector InstallationScr ews 2 Frame Shield Installation Distance a Extension3 Grille Installation Protective Grille Installation 1 Silicone Cap Installation2 Grille End Cap Installation United States Requirements Canadian RequirementsUnvented Operation Horizontal VentingVertical Venting Unvented Operation Tube TerminationHorizontal Ventilation 4 10 cm Pipe Combustible or Non-CombustibleFor Single Vent Flexible Boot Installation Single VentVertical Ventilation 4 10 cm Pipe Common Sidewall Venting Vertical Ventilation 6 15 cm PipeRoof Tube Plan ViewFlexible Boot Installation Common Vent Rolled Sleeve Installation For Common VentOutside Combustion Air Supply Vertical Outside Air SupplyHorizontal Outside Air Supply GAS Piping Incorrect Positions Wrong Installation Correct PositionsWiring Line Voltage Thermostat WiringLow Voltage Thermostat and Relay Wiring Back ViewInternal Wiring Ladder DiagramWire Connector Conduit Hole Electrical Connection to the BurnerOperation and Maintenance Pre-Season Maintenance and Annual InspectionSequence of Operation To Start HeaterVehicles and Other Objects Vent PipeOutside Air Inlet TubesSafety Labels Gas LineBurner Observation WindowTroubleshooting Flow Chart TroubleshootinTroubleshoot Ends Manifold Gas Pressure Setting NaturalPropaneReplacement Parts Description Part Number GAS Pressure AT Manifold Pipe Connection General SpecificationsGAS Inlet Pressure Dimensions Page Limitations on Authority Representatives Warranty is Void ifROBERTS-GORDON LLC will not PAY for Page Page Page
Related manuals
Manual 28 pages 5.15 Kb

TF-380, TF-250, TF-160, TF-200, TF-120 specifications

Roberts Gorden is renowned for its innovative and efficient heating solutions, particularly through its TF series of forced air heaters. The TF-120, TF-200, TF-250, TF-300, and TF-350 models are designed to cater to a variety of applications, offering flexibility, efficiency, and user-friendly operation.

The TF series features advanced combustion technology that ensures high thermal efficiency, significantly reducing fuel consumption while providing optimal heating performance. The heaters utilize a state-of-the-art burner design that allows for quiet operation and minimal emissions, aligning with modern environmental standards.

A standout feature across the TF series is the digital control system, which offers precise temperature management and programmability. The LCD interface allows users to easily adjust settings, monitor performance, and receive diagnostic feedback, enhancing reliability and operational efficiency. The automated controls save energy by modulating operation to only what is necessary to maintain the desired temperature.

The design of the TF-120, TF-200, TF-250, TF-300, and TF-350 models prioritizes durability and ease of installation. Built with rugged materials, these heaters can withstand demanding industrial environments while ensuring long service life. The compact footprint of each model allows for flexible placement, making them suitable for various facilities, including warehouses, workshops, and retail spaces.

Safety is a core attribute of the TF series. Each heater comes equipped with multiple safety features, including over-temperature protection, flame failure detection, and safety shut-off valves. This commitment to safety ensures that users can operate the heaters with peace of mind.

In terms of output capacity, the TF models range to accommodate different heating needs. The TF-120 is perfect for smaller spaces, while the TF-350 caters to larger areas, providing versatility for various industrial applications. Additionally, the heaters can be powered by natural gas or propane, offering flexibility in fuel choice based on user preference or availability.

In summary, Roberts Gorden's TF series—TF-120, TF-200, TF-250, TF-300, and TF-350—delivers a well-rounded heating solution with features such as high thermal efficiency, advanced digital controls, robust safety mechanisms, and a durable design. The adaptability and efficiency of these heaters make them a preferred choice for businesses seeking reliable heating solutions in diverse environments.