Roberts Gorden TF-160, TF-350, TF-300, TF-120 Reflector Side Extension 1 Bracket Installation

Page 39

SECTION 8: OPTIONAL HEATER ACCESSORIES

8.3 Reflector Side Extension

Step 8.3.1 Bracket Installation

 

Tube

Reflector

 

 

 

Tube and Reflector Hanger

 

Reflector Side

Reflector Support

 

Extension Bracket

 

(2 per Reflector)

 

 

Use additional supports

 

in high air movement

 

applications.

 

Description

Part Number

 

Reflector Side Extension Package

02712700

 

Reflector Side Extension

01368000

 

Retainer Clips

02751200

 

Sheet Metal Screws

94118106

 

Order Separately

 

 

Reflector Side Extension

01329910

 

Step 8.3.2 Side Reflector Installation

#8 x 3/8 (3.9 x 9.5 mm) Sheet Metal Screw

Cut relief notches for supports and hangers.

Retainer Clip (2 per Side)

Reflector Side Extension

33

Image 39
Contents Owner InstallerPage Roberts-Gordon LLC Page Table of Figures Page California Proposition Heater SafetyManpower Requirements Safety Labels and Their PlacementTop and Bottom Panel Label Placement Side Panel Label Placement Installer Responsibility Wall TagNational Standards and Applicable Codes Clearances are the required distances that Maintain clearances to combustibles at all times for safetyONE Side Reflector Standard Reflector45 Tilt Reflector Unapproved InchesInches Centimeters UnventedVented National Standards and Applicable Codes Major Components Standard Parts List Contents of Burner CartonContents of Core and Extension Packages Aluminum Reflector Component Package GuideSuggested Layouts TF-380 4 Elbow Design Common Vent10 Typ TF-160 Single Elbow Design Individual Vents Elbow Burner Tube Individual VentOn Page 17, Figure Heater InstallationTypical Suspension Details Linear Heater Assembly Overview Linear Heater Layout Overview 60 18 m Tube Length Each Side Burner Installation Burner Tube InstallationClosed Tube Clamp Package InstallationCoupling and Tube Assembly OpenCorrect slide bar Incorrect slide bar Dimensions Position 1 Coupling and Tube AssemblyTurbulator Installation Burner Hanger Burner Tube Reflector Description Part Number Reflector Support Package 1 Reflector, U-Clip and Reflector Support InstallationOptional Heater Accessories Tube, Standard Tube, Opposite Tube Heater Assembly OverviewTube Heater Layout Overview 70 21 m Tube Length** Each Side Elbow Package Configuration 1 Elbow Installation 2 Elbow Installation3 Reflector Joint Installation Reflector Joint Detail 4 Reflector Joint Installation 5 Reflector Joint Detail2 Side Reflector Installation Reflector Side Extension 1 Bracket InstallationScr ews Distance a Extension 2 Frame Shield InstallationProtective Grille Installation 1 Silicone Cap Installation 2 Grille End Cap Installation3 Grille Installation Horizontal Venting United States RequirementsCanadian Requirements Unvented OperationCombustible or Non-Combustible Vertical VentingUnvented Operation Tube Termination Horizontal Ventilation 4 10 cm PipeFlexible Boot Installation Single Vent Vertical Ventilation 4 10 cm PipeFor Single Vent Tube Plan View Common Sidewall VentingVertical Ventilation 6 15 cm Pipe RoofRolled Sleeve Installation For Common Vent Flexible Boot Installation Common VentVertical Outside Air Supply Outside Combustion Air SupplyHorizontal Outside Air Supply GAS Piping Correct Positions Incorrect Positions Wrong InstallationLine Voltage Thermostat Wiring WiringBack View Low Voltage Thermostat and Relay WiringLadder Diagram Internal WiringElectrical Connection to the Burner Wire Connector Conduit HoleTo Start Heater Operation and MaintenancePre-Season Maintenance and Annual Inspection Sequence of OperationTubes Vehicles and Other ObjectsVent Pipe Outside Air InletWindow Safety LabelsGas Line Burner ObservationTroubleshooting Troubleshootin Flow ChartTroubleshoot Ends NaturalPropane Manifold Gas Pressure SettingReplacement Parts Description Part Number General Specifications GAS Inlet Pressure DimensionsGAS Pressure AT Manifold Pipe Connection Page Warranty is Void if ROBERTS-GORDON LLC will not PAY forLimitations on Authority Representatives Page Page Page
Related manuals
Manual 28 pages 5.15 Kb

TF-380, TF-250, TF-160, TF-200, TF-120 specifications

Roberts Gorden is renowned for its innovative and efficient heating solutions, particularly through its TF series of forced air heaters. The TF-120, TF-200, TF-250, TF-300, and TF-350 models are designed to cater to a variety of applications, offering flexibility, efficiency, and user-friendly operation.

The TF series features advanced combustion technology that ensures high thermal efficiency, significantly reducing fuel consumption while providing optimal heating performance. The heaters utilize a state-of-the-art burner design that allows for quiet operation and minimal emissions, aligning with modern environmental standards.

A standout feature across the TF series is the digital control system, which offers precise temperature management and programmability. The LCD interface allows users to easily adjust settings, monitor performance, and receive diagnostic feedback, enhancing reliability and operational efficiency. The automated controls save energy by modulating operation to only what is necessary to maintain the desired temperature.

The design of the TF-120, TF-200, TF-250, TF-300, and TF-350 models prioritizes durability and ease of installation. Built with rugged materials, these heaters can withstand demanding industrial environments while ensuring long service life. The compact footprint of each model allows for flexible placement, making them suitable for various facilities, including warehouses, workshops, and retail spaces.

Safety is a core attribute of the TF series. Each heater comes equipped with multiple safety features, including over-temperature protection, flame failure detection, and safety shut-off valves. This commitment to safety ensures that users can operate the heaters with peace of mind.

In terms of output capacity, the TF models range to accommodate different heating needs. The TF-120 is perfect for smaller spaces, while the TF-350 caters to larger areas, providing versatility for various industrial applications. Additionally, the heaters can be powered by natural gas or propane, offering flexibility in fuel choice based on user preference or availability.

In summary, Roberts Gorden's TF series—TF-120, TF-200, TF-250, TF-300, and TF-350—delivers a well-rounded heating solution with features such as high thermal efficiency, advanced digital controls, robust safety mechanisms, and a durable design. The adaptability and efficiency of these heaters make them a preferred choice for businesses seeking reliable heating solutions in diverse environments.