Roberts Gorden TF-300 United States Requirements, Canadian Requirements, Unvented Operation

Page 43

SECTION 9: VENTING

SECTION 9: VENTING

WARNING

Carbon Monoxide Hazard

Heaters installed unvented must be interlocked with sufficient building exhaust.

Heaters must be installed according to the installation manual.

Failure to follow these instructions can result in death or injury.

WARNING

Cut/Pinch Hazard

Wear protective gear during installation, operation and service.

Edges are sharp.

Failure to follow these instructions can result in injury.

9.1 Venting Requirements

This heater must be vented in accordance with the rules contained in this manual and with the following national codes and any state, provincial or local codes which may apply:

United States: Refer to National Fuel Gas Code NFPA 54/ANSI Z223.1 - latest revision.

Canada: Refer to Natural Gas and Propane Installation Code CSA B149.1 - latest revision.

Any portion of vent pipe passing through a

combustible wall or roof must be dual insulated (Type

B)vent pipe and have an approved thimble to conform with the above listed codes.

Vent pipe must be sloped downward away from the burner, 1/2" (1 cm) for every 20' (6 m).

Both sides of the TF-Series heater may be

individually vented 4" (10 cm) or common vented 6" (15 cm).

The heater may also be installed unvented in certain

circumstances according to building ventilation codes. Refer to the above codes for further information. Unvented operation also requires compliance with the clearances to combustibles given on Page 9, Figure 12.

The bottom of the vent or air intake terminal shall not be located less than 1' (0.3 m) above grade level.

The vent shall not terminate less than 7' (2.1 m) above grade where located adjacent to public walkways.

Vent terminal must be installed at a height sufficient to prevent blockage by snow and building materials protected from degradation by flue gases.

Vent must be at least 6' (2 m) from the combustion air opening of this unit, or any other appliance. Secure all joints with #8 x 3/8 sheet metal screws. Seal all joints with high temperature silicone sealant. Vent terminal must be beyond any combustible overhang.

9.1.1 United States Requirements

Vent must terminate at least 3' (0.9 m) above any forced air inlet located within 10' (3.1 m).

Vent must terminate at least 4' (1.2 m) below, 4' (1.2 m) horizontally from, or 1' (0.3 m) above any door, operable window, or gravity air inlet into any building.

9.1.2 Canadian Requirements

The vent shall not terminate within 6' (1.8 m) of a mechanical air supply inlet to any building.

The vent shall not terminate within 3' (0.9 m) of a window or door that can be opened in any building, any non-mechanical air supply inlet to any building, or of the combustion air inlet of any other appliance.

9.2 Unvented Operation

Sufficient ventilation must be provided in the amount of 4 cfm per 1000 BTU/hr firing rate (United States); 3 cfm per 1000 BTU/hr firing rate (Canada).

Use of optional outside combustion air is not recommended with unvented heaters.

If exhaust fans are used to supply ventilation air, an interlock switch must be used to prevent the heater from coming on when the fans are off. This may be done using a pressure switch.

9.3 Horizontal Venting

In noncombustible walls only, vent terminal (P/N 02537801-1P) may be used.

For 4" (10 cm) vents in either combustible or noncombustible walls, use Tjernlund VH1-4 (P/N 90502100) or equivalent, insulated vent terminal. Follow the manufacturer's instructions for proper installation.

For 6" (15 cm) common vents in either combustible or noncombustible walls, use Tjernlund VH1-6 (P/N 90502101) or equivalent, insulated vent terminal.

Follow the manufacturer's instructions for proper installation.

37

Image 43
Contents Owner InstallerPage Roberts-Gordon LLC Page Table of Figures Page California Proposition Heater SafetyManpower Requirements Safety Labels and Their PlacementTop and Bottom Panel Label Placement Side Panel Label Placement Wall Tag Installer ResponsibilityNational Standards and Applicable Codes Clearances are the required distances that Maintain clearances to combustibles at all times for safetyONE Side Reflector Standard Reflector45 Tilt Reflector Unapproved InchesUnvented Inches CentimetersVented National Standards and Applicable Codes Major Components Contents of Burner Carton Standard Parts ListContents of Core and Extension Packages Aluminum Reflector Component Package GuideTF-380 4 Elbow Design Common Vent Suggested Layouts10 Typ TF-160 Single Elbow Design Individual Vents Elbow Burner Tube Individual VentOn Page 17, Figure Heater InstallationTypical Suspension Details Linear Heater Assembly Overview Linear Heater Layout Overview 60 18 m Tube Length Each Side Burner Installation Burner Tube InstallationClosed Tube Clamp Package InstallationCoupling and Tube Assembly OpenCorrect slide bar Incorrect slide bar Dimensions Position 1 Coupling and Tube AssemblyTurbulator Installation Burner Hanger Burner Tube Reflector Description Part Number Reflector Support Package 1 Reflector, U-Clip and Reflector Support InstallationOptional Heater Accessories Tube, Standard Tube, Opposite Tube Heater Assembly OverviewTube Heater Layout Overview 70 21 m Tube Length** Each Side 2 Elbow Installation Elbow Package Configuration 1 Elbow Installation3 Reflector Joint Installation Reflector Joint Detail 4 Reflector Joint Installation 5 Reflector Joint Detail2 Side Reflector Installation Reflector Side Extension 1 Bracket InstallationScr ews Distance a Extension 2 Frame Shield Installation2 Grille End Cap Installation Protective Grille Installation 1 Silicone Cap Installation3 Grille Installation Horizontal Venting United States RequirementsCanadian Requirements Unvented OperationCombustible or Non-Combustible Vertical VentingUnvented Operation Tube Termination Horizontal Ventilation 4 10 cm PipeVertical Ventilation 4 10 cm Pipe Flexible Boot Installation Single VentFor Single Vent Tube Plan View Common Sidewall VentingVertical Ventilation 6 15 cm Pipe RoofRolled Sleeve Installation For Common Vent Flexible Boot Installation Common VentVertical Outside Air Supply Outside Combustion Air SupplyHorizontal Outside Air Supply GAS Piping Correct Positions Incorrect Positions Wrong InstallationLine Voltage Thermostat Wiring WiringBack View Low Voltage Thermostat and Relay WiringLadder Diagram Internal WiringElectrical Connection to the Burner Wire Connector Conduit HoleTo Start Heater Operation and MaintenancePre-Season Maintenance and Annual Inspection Sequence of OperationTubes Vehicles and Other ObjectsVent Pipe Outside Air InletWindow Safety LabelsGas Line Burner ObservationTroubleshooting Troubleshootin Flow ChartTroubleshoot Ends NaturalPropane Manifold Gas Pressure SettingReplacement Parts Description Part Number GAS Inlet Pressure Dimensions General SpecificationsGAS Pressure AT Manifold Pipe Connection Page ROBERTS-GORDON LLC will not PAY for Warranty is Void ifLimitations on Authority Representatives Page Page Page
Related manuals
Manual 28 pages 5.15 Kb

TF-380, TF-250, TF-160, TF-200, TF-120 specifications

Roberts Gorden is renowned for its innovative and efficient heating solutions, particularly through its TF series of forced air heaters. The TF-120, TF-200, TF-250, TF-300, and TF-350 models are designed to cater to a variety of applications, offering flexibility, efficiency, and user-friendly operation.

The TF series features advanced combustion technology that ensures high thermal efficiency, significantly reducing fuel consumption while providing optimal heating performance. The heaters utilize a state-of-the-art burner design that allows for quiet operation and minimal emissions, aligning with modern environmental standards.

A standout feature across the TF series is the digital control system, which offers precise temperature management and programmability. The LCD interface allows users to easily adjust settings, monitor performance, and receive diagnostic feedback, enhancing reliability and operational efficiency. The automated controls save energy by modulating operation to only what is necessary to maintain the desired temperature.

The design of the TF-120, TF-200, TF-250, TF-300, and TF-350 models prioritizes durability and ease of installation. Built with rugged materials, these heaters can withstand demanding industrial environments while ensuring long service life. The compact footprint of each model allows for flexible placement, making them suitable for various facilities, including warehouses, workshops, and retail spaces.

Safety is a core attribute of the TF series. Each heater comes equipped with multiple safety features, including over-temperature protection, flame failure detection, and safety shut-off valves. This commitment to safety ensures that users can operate the heaters with peace of mind.

In terms of output capacity, the TF models range to accommodate different heating needs. The TF-120 is perfect for smaller spaces, while the TF-350 caters to larger areas, providing versatility for various industrial applications. Additionally, the heaters can be powered by natural gas or propane, offering flexibility in fuel choice based on user preference or availability.

In summary, Roberts Gorden's TF series—TF-120, TF-200, TF-250, TF-300, and TF-350—delivers a well-rounded heating solution with features such as high thermal efficiency, advanced digital controls, robust safety mechanisms, and a durable design. The adaptability and efficiency of these heaters make them a preferred choice for businesses seeking reliable heating solutions in diverse environments.