TF-SERIES INSTALLATION, OPERATION AND SERVICE MANUAL

5.1 Standard Parts List

Table 1: Contents of Burner Carton

Part No.

Description

TF-120

TF-160

TF-200

TF-250

TF-300

TF-350

TF-380

 

 

 

 

 

 

 

 

 

090XXXXX

Burner Assembly (Rate and Fuel Varies)

1

1

1

1

1

1

1

 

 

 

 

 

 

 

 

 

02568200

Gasket (Burner to Burner Tube)

1

1

1

1

1

1

1

 

 

 

 

 

 

 

 

 

190100NA

Installation, Operation and Service Manual

1

1

1

1

1

1

1

 

 

 

 

 

 

 

 

 

94273914

Hex Head Bolts 5/16-18 Rolok

8

8

8

8

8

8

8

 

 

 

 

 

 

 

 

 

96411600

Split Lock washer

8

8

8

8

8

8

8

 

 

 

 

 

 

 

 

 

*91412204

Flexible Stainless Steel Gas Hose - 3/4" NPT (US Models Only)

1

1

1

1

1

1

1

 

 

 

 

 

 

 

 

 

03051503

Turbulator Adapter

2

2

2

-

-

-

-

 

 

 

 

 

 

 

 

 

03051504

Turbulator 2.5' (76 cm) Aluminized Steel

8

8

4

-

-

-

-

 

 

 

 

 

 

 

 

 

91412800

Flexible Boot

2

2

2

2

2

2

2

 

 

 

 

 

 

 

 

 

91901300

Boot Clamp

4

4

4

4

4

4

4

 

 

 

 

 

 

 

 

 

09080000

Vent Sleeve

2

2

2

2

2

2

2

 

 

 

 

 

 

 

 

 

*Canadian Models: Rubber (Type 1) Gas Hoses available as an accessory. See Page 44, Section 10.

Table 2: Contents of Core and Extension Packages

 

 

 

 

Core Packages

 

 

 

 

 

Extension Packages

 

 

 

 

 

 

 

 

 

 

 

 

 

Hot Rolled

Aluminized

Aluminized

Hot Rolled

Aluminized with

Aluminized with

 

 

 

with

 

 

with

 

with Stain-

 

with

 

Aluminum

Stainless Steel

 

 

Aluminum

Aluminum

less Steel

Aluminum

 

Reflector

 

 

Reflector

 

 

 

Reflector

Reflector

Reflector

 

Reflector

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Part No.

Description

20'

30'

40'

20' 30' 40'

20' 30' 40'

10' 20' 30' 40'

10' 20' 30' 40'

10' 20' 30' 40'

 

 

(6m)

(9m)

(12m)

(6m)

(9m) (12m)

(6m)

(9m)

(12m)

(3m)

(6m)

(9m)

(12m

(3m)

(6m)

(9m)

(12m

(3m)

(6m)

(9m)

(12m

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

91409300

Tube, Hot Rolled Steel, 10' (3m)

1

2

3

-

-

-

-

-

-

1

2

3

4

-

-

-

-

-

-

-

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

91409408

Tube, HT Aluminized, 10' (3m)

-

-

-

1

2

3

1

2

3

-

-

-

-

1

2

3

4

1

2

3

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

03051101

Burner Tube, ALUMI-THERM®Steel, 10' (3m)

-

1

1

-

1

1

-

1

1

-

-

-

-

-

-

-

-

-

-

-

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

03051601

Burner Tube, HT ALUMI-THERM®Steel, 10' (3m)

1

-

-

1

-

-

1

-

-

-

-

-

-

-

-

-

-

-

-

-

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

01312700

Coupling Assembly

1

2

3

1

2

3

1

2

3

1

2

3

4

1

2

3

4

1

2

3

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

02750303

Standard Reflector, 8' (3.5m)

3

4

6

3

4

6

-

-

-

2

3

4

6

2

3

4

6

-

-

-

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

02750800

End Cap

2

2

2

2

2

2

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

027503SS

Stainless Steel Reflector, 8’ (3.5m)

-

-

-

-

-

-

3

4

6

-

-

-

-

-

-

-

-

2

3

4

6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

027508SS

Stainless Steel End Cap

-

-

-

-

-

-

2

2

2

-

-

-

-

-

-

-

-

-

-

-

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

03090100

Tube and Reflector Hanger

3

4

5

3

4

5

3

4

5

1

2

3

4

1

2

3

4

1

2

3

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

91907302

S-Hook

6

8

10

6

8

10

6

8

10

2

4

6

8

2

4

6

8

2

4

6

8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

03050010

Reflector Support Package

2

3

5

2

3

5

4

5

7

2

3

4

6

2

3

4

6

2

3

4

6

 

(Strap, Wire Form, Screws)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

91107720

U-Clip Package

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

90502700

Vent Adapter (Not required for TF Models)

1

1

1

1

1

1

1

1

1

-

-

-

-

-

-

-

-

-

-

-

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

01318901

Tube Clamp Package

1

1

1

1

1

1

2

2

2

-

-

-

-

-

-

-

-

-

-

-

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Part Number

CP20HRS

CP30HRS

CP40HRS

CP20ALUM

CP30ALUM

CP40ALUM

CP20ALUMSS

CP30ALUMSS

CP40ALUMSS

EXP10HRS

EXP20HRS

EXP30HRS

EXP40HRS

EXP10ALUM

EXP20ALUM

EXP30ALUM

EXP40ALUM

EXP10ALUMSS

EXP20ALUMSS

EXP30ALUMSS

EXP40ALUMSS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12

Image 18
Contents Installer OwnerPage Roberts-Gordon LLC Page Table of Figures Page Safety Labels and Their Placement Heater SafetyManpower Requirements California PropositionTop and Bottom Panel Label Placement Side Panel Label Placement Installer Responsibility Wall TagNational Standards and Applicable Codes Maintain clearances to combustibles at all times for safety Clearances are the required distances thatStandard Reflector ONE Side Reflector45 Tilt Reflector Inches UnapprovedInches Centimeters UnventedVented National Standards and Applicable Codes Major Components Standard Parts List Contents of Burner CartonContents of Core and Extension Packages Component Package Guide Aluminum ReflectorSuggested Layouts TF-380 4 Elbow Design Common Vent10 Typ Elbow Burner Tube Individual Vent TF-160 Single Elbow Design Individual VentsHeater Installation On Page 17, FigureTypical Suspension Details Linear Heater Assembly Overview Linear Heater Layout Overview 60 18 m Tube Length Each Side Burner Tube Installation Burner InstallationOpen Tube Clamp Package InstallationCoupling and Tube Assembly Closed1 Coupling and Tube Assembly Correct slide bar Incorrect slide bar Dimensions PositionTurbulator Installation Burner Hanger Burner Tube Reflector 1 Reflector, U-Clip and Reflector Support Installation Description Part Number Reflector Support PackageOptional Heater Accessories Tube Heater Assembly Overview Tube, Standard Tube, OppositeTube Heater Layout Overview 70 21 m Tube Length** Each Side Elbow Package Configuration 1 Elbow Installation 2 Elbow Installation3 Reflector Joint Installation 4 Reflector Joint Installation 5 Reflector Joint Detail Reflector Joint DetailReflector Side Extension 1 Bracket Installation 2 Side Reflector InstallationScr ews 2 Frame Shield Installation Distance a ExtensionProtective Grille Installation 1 Silicone Cap Installation 2 Grille End Cap Installation3 Grille Installation Unvented Operation United States RequirementsCanadian Requirements Horizontal VentingHorizontal Ventilation 4 10 cm Pipe Vertical VentingUnvented Operation Tube Termination Combustible or Non-CombustibleFlexible Boot Installation Single Vent Vertical Ventilation 4 10 cm PipeFor Single Vent Roof Common Sidewall VentingVertical Ventilation 6 15 cm Pipe Tube Plan ViewFlexible Boot Installation Common Vent Rolled Sleeve Installation For Common VentOutside Combustion Air Supply Vertical Outside Air SupplyHorizontal Outside Air Supply GAS Piping Incorrect Positions Wrong Installation Correct PositionsWiring Line Voltage Thermostat WiringLow Voltage Thermostat and Relay Wiring Back ViewInternal Wiring Ladder DiagramWire Connector Conduit Hole Electrical Connection to the BurnerSequence of Operation Operation and MaintenancePre-Season Maintenance and Annual Inspection To Start HeaterOutside Air Inlet Vehicles and Other ObjectsVent Pipe TubesBurner Observation Safety LabelsGas Line WindowTroubleshooting Flow Chart TroubleshootinTroubleshoot Ends Manifold Gas Pressure Setting NaturalPropaneReplacement Parts Description Part Number General Specifications GAS Inlet Pressure DimensionsGAS Pressure AT Manifold Pipe Connection Page Warranty is Void if ROBERTS-GORDON LLC will not PAY forLimitations on Authority Representatives Page Page Page
Related manuals
Manual 28 pages 5.15 Kb

TF-380, TF-250, TF-160, TF-200, TF-120 specifications

Roberts Gorden is renowned for its innovative and efficient heating solutions, particularly through its TF series of forced air heaters. The TF-120, TF-200, TF-250, TF-300, and TF-350 models are designed to cater to a variety of applications, offering flexibility, efficiency, and user-friendly operation.

The TF series features advanced combustion technology that ensures high thermal efficiency, significantly reducing fuel consumption while providing optimal heating performance. The heaters utilize a state-of-the-art burner design that allows for quiet operation and minimal emissions, aligning with modern environmental standards.

A standout feature across the TF series is the digital control system, which offers precise temperature management and programmability. The LCD interface allows users to easily adjust settings, monitor performance, and receive diagnostic feedback, enhancing reliability and operational efficiency. The automated controls save energy by modulating operation to only what is necessary to maintain the desired temperature.

The design of the TF-120, TF-200, TF-250, TF-300, and TF-350 models prioritizes durability and ease of installation. Built with rugged materials, these heaters can withstand demanding industrial environments while ensuring long service life. The compact footprint of each model allows for flexible placement, making them suitable for various facilities, including warehouses, workshops, and retail spaces.

Safety is a core attribute of the TF series. Each heater comes equipped with multiple safety features, including over-temperature protection, flame failure detection, and safety shut-off valves. This commitment to safety ensures that users can operate the heaters with peace of mind.

In terms of output capacity, the TF models range to accommodate different heating needs. The TF-120 is perfect for smaller spaces, while the TF-350 caters to larger areas, providing versatility for various industrial applications. Additionally, the heaters can be powered by natural gas or propane, offering flexibility in fuel choice based on user preference or availability.

In summary, Roberts Gorden's TF series—TF-120, TF-200, TF-250, TF-300, and TF-350—delivers a well-rounded heating solution with features such as high thermal efficiency, advanced digital controls, robust safety mechanisms, and a durable design. The adaptability and efficiency of these heaters make them a preferred choice for businesses seeking reliable heating solutions in diverse environments.