Roberts Gorden TF-250, TF-350, TF-300, TF-120, TF-200 Component Package Guide, Aluminum Reflector

Page 19

 

 

 

 

SECTION 5: MAJOR COMPONENTS

Table 3: Component Package Guide

 

 

 

 

 

 

 

 

Tubing Length Each Side

 

Core Packages (2 Required)

 

 

 

 

 

 

Model

Minimum

Hot Rolled with

Aluminized with

Aluminized with

 

 

Aluminum Reflector

Aluminum Reflector

Stainless Steel Reflector

 

 

 

 

 

TF-120

20' (6 m)

CP20HRS

CP20ALUM

CP20ALUMSS

 

 

 

 

 

TF-160

20' (6 m)

CP20HRS

CP20ALUM

CP20ALUMSS

 

 

 

 

 

TF-200

30' (9 m)

CP30HRS

CP30ALUM

CP30ALUMSS

 

 

 

 

 

TF-250

40' (12 m)

CP40HRS

CP40ALUM

CP40ALUMSS

 

 

 

 

 

TF-300

50' (15 m)

CP30HRS + EXP20HRS

CP30ALUM + EXP20ALUM

CP30ALUMSS + EXP20ALUMSS

 

 

 

 

 

TF-350

50' (15 m)

CP30HRS + EXP20HRS

CP30ALUM + EXP20ALUM

CP30ALUMSS + EXP20ALUMSS

 

 

 

 

 

TF-380

60' (18 m)

CP30HRS + EXP30HRS

CP30ALUM + EXP30ALUM

CP30ALUMSS + EXP30ALUMSS

 

 

 

 

 

Additional tubing length may be added to heater. Tubing must be heat-treated, aluminized or porcelain coated. Any additional tubing lengths are considered as vent length for length determination. Maximum venting length for minimum heater length is 45' (13.7 m) total, or 22.5' (7 m) on each tube.

13

Image 19
Contents Owner InstallerPage Roberts-Gordon LLC Page Table of Figures Page California Proposition Heater SafetyManpower Requirements Safety Labels and Their PlacementTop and Bottom Panel Label Placement Side Panel Label Placement Wall Tag Installer ResponsibilityNational Standards and Applicable Codes Clearances are the required distances that Maintain clearances to combustibles at all times for safetyONE Side Reflector Standard Reflector45 Tilt Reflector Unapproved InchesUnvented Inches CentimetersVented National Standards and Applicable Codes Major Components Contents of Burner Carton Standard Parts ListContents of Core and Extension Packages Aluminum Reflector Component Package GuideTF-380 4 Elbow Design Common Vent Suggested Layouts10 Typ TF-160 Single Elbow Design Individual Vents Elbow Burner Tube Individual VentOn Page 17, Figure Heater InstallationTypical Suspension Details Linear Heater Assembly Overview Linear Heater Layout Overview 60 18 m Tube Length Each Side Burner Installation Burner Tube InstallationClosed Tube Clamp Package InstallationCoupling and Tube Assembly OpenCorrect slide bar Incorrect slide bar Dimensions Position 1 Coupling and Tube AssemblyTurbulator Installation Burner Hanger Burner Tube Reflector Description Part Number Reflector Support Package 1 Reflector, U-Clip and Reflector Support InstallationOptional Heater Accessories Tube, Standard Tube, Opposite Tube Heater Assembly OverviewTube Heater Layout Overview 70 21 m Tube Length** Each Side 2 Elbow Installation Elbow Package Configuration 1 Elbow Installation3 Reflector Joint Installation Reflector Joint Detail 4 Reflector Joint Installation 5 Reflector Joint Detail2 Side Reflector Installation Reflector Side Extension 1 Bracket InstallationScr ews Distance a Extension 2 Frame Shield Installation2 Grille End Cap Installation Protective Grille Installation 1 Silicone Cap Installation3 Grille Installation Horizontal Venting United States RequirementsCanadian Requirements Unvented OperationCombustible or Non-Combustible Vertical VentingUnvented Operation Tube Termination Horizontal Ventilation 4 10 cm PipeVertical Ventilation 4 10 cm Pipe Flexible Boot Installation Single VentFor Single Vent Tube Plan View Common Sidewall VentingVertical Ventilation 6 15 cm Pipe RoofRolled Sleeve Installation For Common Vent Flexible Boot Installation Common VentVertical Outside Air Supply Outside Combustion Air SupplyHorizontal Outside Air Supply GAS Piping Correct Positions Incorrect Positions Wrong InstallationLine Voltage Thermostat Wiring WiringBack View Low Voltage Thermostat and Relay WiringLadder Diagram Internal WiringElectrical Connection to the Burner Wire Connector Conduit HoleTo Start Heater Operation and MaintenancePre-Season Maintenance and Annual Inspection Sequence of OperationTubes Vehicles and Other ObjectsVent Pipe Outside Air InletWindow Safety LabelsGas Line Burner ObservationTroubleshooting Troubleshootin Flow ChartTroubleshoot Ends NaturalPropane Manifold Gas Pressure SettingReplacement Parts Description Part Number GAS Inlet Pressure Dimensions General SpecificationsGAS Pressure AT Manifold Pipe Connection Page ROBERTS-GORDON LLC will not PAY for Warranty is Void ifLimitations on Authority Representatives Page Page Page
Related manuals
Manual 28 pages 5.15 Kb

TF-380, TF-250, TF-160, TF-200, TF-120 specifications

Roberts Gorden is renowned for its innovative and efficient heating solutions, particularly through its TF series of forced air heaters. The TF-120, TF-200, TF-250, TF-300, and TF-350 models are designed to cater to a variety of applications, offering flexibility, efficiency, and user-friendly operation.

The TF series features advanced combustion technology that ensures high thermal efficiency, significantly reducing fuel consumption while providing optimal heating performance. The heaters utilize a state-of-the-art burner design that allows for quiet operation and minimal emissions, aligning with modern environmental standards.

A standout feature across the TF series is the digital control system, which offers precise temperature management and programmability. The LCD interface allows users to easily adjust settings, monitor performance, and receive diagnostic feedback, enhancing reliability and operational efficiency. The automated controls save energy by modulating operation to only what is necessary to maintain the desired temperature.

The design of the TF-120, TF-200, TF-250, TF-300, and TF-350 models prioritizes durability and ease of installation. Built with rugged materials, these heaters can withstand demanding industrial environments while ensuring long service life. The compact footprint of each model allows for flexible placement, making them suitable for various facilities, including warehouses, workshops, and retail spaces.

Safety is a core attribute of the TF series. Each heater comes equipped with multiple safety features, including over-temperature protection, flame failure detection, and safety shut-off valves. This commitment to safety ensures that users can operate the heaters with peace of mind.

In terms of output capacity, the TF models range to accommodate different heating needs. The TF-120 is perfect for smaller spaces, while the TF-350 caters to larger areas, providing versatility for various industrial applications. Additionally, the heaters can be powered by natural gas or propane, offering flexibility in fuel choice based on user preference or availability.

In summary, Roberts Gorden's TF series—TF-120, TF-200, TF-250, TF-300, and TF-350—delivers a well-rounded heating solution with features such as high thermal efficiency, advanced digital controls, robust safety mechanisms, and a durable design. The adaptability and efficiency of these heaters make them a preferred choice for businesses seeking reliable heating solutions in diverse environments.