York YZE024 THRU 060 warranty Footnotes, Procedures

Page 3

 

 

 

 

246750-YTG-L-0408

Additional R-410A Charge / TXV Size for Various Matched Systems

 

 

 

 

 

 

 

Outdoor Unit

YZE02411

YZE03611

YZE04811

YZE06011

Approved System Thermal Expansion Valve1

1TVM902

1TVM902

1TVM905

1TVM906

1TVM4A1

 

 

 

 

Factory R-410A Charge, lbs-oz

8 - 14

8 - 8

14 - 8

14 - 0

 

 

 

 

 

Indoor Coil2

 

TXV Kit3 - Additional Charge, Oz

 

FC/MC/PC/UC30A

+ 4

FC/MC/PC/UC30B

+ 4

FC/MC/PC32A

+ 6

FC/MC/PC35B

+ 6

+ 0

FC/MC/PC35C

+ 6

+ 0

FC/MC/PC/UC36A

+ 5

FC/MC/PC/UC36B

+ 5

FC/MC/PC36C

+ 5

FC/MC/PC/UC42B

+ 12

+ 0

FC/MC/PC/UC42C

+ 12

+ 0

FC/MC/PC/UC48C

+ 14

FC/MC/PC/UC48D

+ 14

FC/PC/UC60C

+ 9

+ 9

FC/MC/PC/UC60D

+ 9

+ 9

FC/MC62D

+ 17

+ 16

HC30

+ 4

HC36

+ 6

HC42

+ 12

HC60

+ 9

+ 9

HD24

HD36

+ 6

HD48

+ 10

HD60

+ 9

+ 9

AV24

+ 4

AV36

+ 12

+ 0

AV/SV48

+ 17

+ 9

AV/SV60

+ 9

+ 9

F*FV060

+ 9

+ 9

FOOTNOTES:

 

 

 

 

1.Systems matched with furnace or air handlers not equipped with blower-off delays may require blower Time Delay Kit 2FD06700224.

2.PC coils cannot be used in downflow or horizontal applications. FC coils cannot be used in horizontal applications.

3.A TXV kit must be used with these coils to obtain system performance.

Note: If a TXV is factory installed on the coil, it must be replaced with the listed TXV.

PROCEDURES:

1.Unit factory charge listed on the unit nameplate includes refrigerant for the condenser, the smallest evaporator and 15 feet of intercon- necting line tubing.

2.Verify the TXV and additional charge required for specific evaporator coil in the system using the above table.

3.Additional charge for the amount of interconnecting line tubing greater than 15 feet at the rate specified in the Physical and Electrical Data Table.

4.Permanently mark the unit nameplate with the total system charge. Total System Charge = Base Charge (as shipped) + adder for evap- orator + adder for line set.

Johnson Controls Unitary Products

3

Image 3
Contents Warranty FeaturesDescription Model Physical and Electrical DataFootnotes ProceduresMBH Cooling Capacity With Air Handler CoilsCooling Capacity With Variable Speed Furnaces Variable SpeedSensible FC/MC/PC/UC60C 47 OD 17 OD Heating Capacity With Air Handler CoilsHeating Capacity With Variable Speed Furnaces 650 23.0 1200 33.0 20.8 29.4 19.6 PV8*B16 860 31.2 1610 48.0 27.8 44.5 26.2 PC,V9*C20 Choice of Several Color Coil Grilles to Compliment ANY Home AccessoriesSound Power Ratings Color GrillesLOW CFM Cooling Performance Data LOW CFM 1-STAGE OperationOutdoor Unit Model no Indoor Coil Model noHigh CFM Cooling Performance Data High CFM 2-STAGE OperationYZE03611 1100 1200 1300 YZE04811 1500 1600 1700 YZE06011 1600 1800 2000 Heating Performance Data LOW CFM 1-STAGE Operation Indoor Coil Model no FC/MC/PC36B + MV12BMBH COP Heating Performance Data High CFM 2-STAGE Operation Indoor Coil Model no FC/MC/PC48C + MV16C 1200 1300 Indoor Coil Model no FC/MC/PC60D + MV20D 1500 1600 1700 1150 1200 1750 1850 1950 Johnson Controls Unitary Products York Drive Norman, OK

YZE024 THRU 060 specifications

The York YZE024 THRU 060 is a remarkable range of packaged unit air conditioners designed for excellent performance and efficiency in various commercial and industrial applications. These units stand out for their high-quality construction and advanced technology, making them an ideal choice for heating and cooling solutions.

One of the primary features of the YZE series is its variable-speed compressor. This technology allows for precise temperature control while optimizing energy consumption. By adjusting the compressor speed according to the cooling demand, these units enhance comfort and significantly reduce energy costs. The efficiency ratings are among the best in the industry, with many units achieving an impressive SEER (Seasonal Energy Efficiency Ratio) that meets or exceeds regulatory requirements.

The YZE024 THRU 060 units come with advanced airflow management systems that help improve indoor air quality and system performance. The integrated multi-speed blower ensures consistent airflow and quiet operation, providing a comfortable environment for occupants. Furthermore, the optimized fan design minimizes pressure drop, contributing to additional energy savings.

Another characteristic of the YZE series is the intelligent control technology. Equipped with a user-friendly digital thermostat, these units offer customization options that allow operators to program settings according to specific needs and preferences. Additionally, the units are compatible with smart building automation systems, facilitating remote monitoring and control capabilities.

Durability is a vital aspect of the York YZE series. Each unit is constructed using high-strength materials designed to resist harsh environmental conditions. The corrosion-resistant cabinet ensures longevity and reliability, even in demanding climates. Moreover, the internal components are designed for easy access, simplifying maintenance and reducing downtime.

The York YZE024 THRU 060 series also incorporates eco-friendly refrigerants, aligning with modern environmental standards and minimizing the carbon footprint. The commitment to sustainability is evident in every aspect, from manufacturing to end-of-life disposal.

In summary, the York YZE024 THRU 060 range combines advanced technology with durability and efficiency. Its variable-speed compressor, intelligent controls, and robust construction make it an excellent choice for end-users seeking reliable climate control solutions.