Toshiba RAV-SM2802DT-E, RAV-SM2242DT-E Remote Controller Wiring, Wiring diagram, Group control

Page 28

Concealed Duct High Static Pressure

 

 

(Unit: mm)

Group control

 

 

 

 

 

 

Wired remote

 

10

 

controller

 

 

 

10

R (L) S (N)

 

 

 

 

 

A B

 

40

 

Indoor Unit

30

 

 

Outdoor Unit

Indoor fan power supply wire

Installation Manual

A B

Indoor Unit

Outdoor Unit

1 2 3

30 10

40 10

System interconnecting wire

!Remote Controller Wiring

Strip off approx. 9mm the wire to be connected.

Non polarity, 2 core wire is used for wiring of the remote controller. (0.5mm² to 2.0mm² wires)

Wiring diagram

Terminal block for remote controller wiring of indoor unit

A

B

Remote controller wire (Locally procured)

Terminal block

A

Remote

controller

B

unit

 

 

 

27-EN

– 27 –

Image 28
Contents Installation Manual Contents Concealed Duct High Static Pressure Installation Manual Agent Qualifications and knowledge which the agent must haveWork undertaken Protective gear worn Burst Hazard Precautions for Safety Selection of installation locationInstallation GeneralElectrical wiring Test runExplanations given to user RelocationTo Disconnect the Appliance from Main Power Supply Part name ’ty Accessory PartsUsage Installation under high-humidity atmosphere Selection of Installation PlaceAvoid installing in the following places Installation space Filter cleaning sign term settingInstallation example Unit mmInstallation External DimensionsInstallation of hanging bolt Installation of indoor unitInstallation of hanging bolt Treatment of ceilingAir inlet port connecting flange Diagrams for making connecting flangesAir outlet port flange Duct installation example First floor Duct designFAN Characteristics RAV-SM2242 TypeRAV-SM2802 Type Wire connection change of fan motor Low static pressure F1Standard Middle static pressure F2 High static pressure F3Drain Piping Work Connecting drain pipe Pipe material, size and insulatorDrain up Pipe materialCheck the draining Heat insulating process Refrigerant Piping and Evacuating Refrigerant PipingPipe size Liquid side refrigerant pipe connectionGas side refrigerant pipe connection EvacuationTightening connection Piping with outdoor unitRefrigerant amount to be added Open the valve fullyGas leak check Heat insulation processWiring diagram Power and Wiring SpecificationRemote controller wiring WiringWire connection Terminal block of electrical control boxWiring diagram Remote Controller WiringGroup control Changing of setting applicable control When power is turned on for the second or later timeBasic procedure for changing settings Applicable ControlsFilter sign setting Power saving modeDetection temperature shift value To secure better effect of heatingRemote controller switch monitoring function Outdoor unit dataCode No Data name Indoor unit dataGroup control Group control for system of multiple unitsProcedure example Manual address setup procedure33-EN 8C Operation 0000Before test run 10TEST RUNExecute a test run 11MAINTENANCE Daily maintenance Cleaning of air filterMaintenance List Part Unit Check visual/auditory MaintenanceConfirmation of error log 12TROUBLESHOOTINGConfirmation and check Error codes and parts to be checked Status40-EN
Related manuals
Manual 110 pages 30.72 Kb

RAV-SM2242DT-E, RAV-SM2802DT-E specifications

Toshiba has long been a leader in heating, ventilation, and air conditioning (HVAC) technology, offering innovative solutions that cater to both residential and commercial needs. Among their impressive lineup, the Toshiba RAV-SM2802DT-E and RAV-SM2242DT-E stand out as exceptional models designed for efficiency, performance, and comfort.

The RAV-SM2802DT-E is a powerful unit ideal for larger spaces, boasting a cooling capacity of 28,000 BTU/h and a heating capacity of 31,000 BTU/h. This model features a highly efficient inverter compressor, which adjusts the power consumption based on the cooling or heating demand, ensuring optimal energy use. This inverter technology not only reduces energy consumption but also maintains a stable indoor temperature for enhanced comfort.

On the other hand, the RAV-SM2242DT-E is tailored for mid-sized applications with a cooling capacity of 22,000 BTU/h and a heating capacity of 25,000 BTU/h. This model also embraces inverter technology, promoting lower operational costs while delivering reliable performance. Both units come with a high energy efficiency rating, reducing environmental impact and saving on utility bills.

One of the key characteristics of these Toshiba models is their advanced filtration system. Equipped with a high-performance filtration mechanism, they can effectively reduce dust, allergens, and other pollutants, ensuring a healthier indoor environment. The units also operate quietly, contributing to a peaceful atmosphere, whether in a home, office, or commercial space.

Both the RAV-SM2802DT-E and RAV-SM2242DT-E are designed with user convenience in mind. They come with a user-friendly remote control, allowing for easy adjustments and settings from anywhere in the room. Compatibility with smart home systems further enhances user experience by enabling remote monitoring and control through smartphones or tablets.

Constructed with durability in mind, these units are built to withstand diverse weather conditions, making them suitable for various climatic environments. Additionally, their aesthetic design allows for seamless integration into any setting, ensuring that performance does not compromise on looks.

In summary, Toshiba's RAV-SM2802DT-E and RAV-SM2242DT-E offer a blend of superior technology, energy efficiency, and user-friendly features. With their inverter technology, advanced filtration systems, and durable designs, these models represent Toshiba's commitment to quality and innovation in the HVAC industry. Whether for residential or commercial applications, these units guarantee comfort and reliability all year round.