Toshiba RAV-SM2802DT-E Precautions for Safety, General, Selection of installation location

Page 6

Concealed Duct High Static Pressure

Installation Manual

 

1 PRECAUTIONS FOR SAFETY

WARNING

General

Before starting to install the air conditioner, read carefully through the Installation Manual, and follow its instructions to install the air conditioner.

Only a qualified installer(*1) or qualified service person(*1) is allowed to install the air conditioner. If the air conditioner is installed by an unqualified individual, a fire, electric shocks, injury, water leakage, noise and/or vibration may result.

Before opening the intake grille of the indoor unit or service panel of the outdoor unit, set the circuit breaker to the OFF position. Failure to set the circuit breaker to the OFF position may result in electric shocks through contact with the interior parts. Only a qualified installer(*1) or qualified service person(*1) is allowed to remove the intake grille of the indoor unit or service panel of the outdoor unit and do the work required.

Before carrying out the installation, maintenance, repair or removal work, be sure to set the circuit breaker to the OFF position. Otherwise, electric shocks may result.

Place a “Work in progress” sign near the circuit breaker while the installation, maintenance, repair or removal work is being carried out. There is a danger of electric shocks if the circuit breaker is set to ON by mistake.

Only a qualified installer(*1) or qualified service person(*1) is allowed to undertake work at heights using a stand of 50 cm or more or to remove the intake grille of the indoor unit to undertake work.

Wear protective gloves and safety work clothing during installation, servicing and removal.

Do not touch the aluminium fin of the outdoor unit. You may injure yourself if you do so. If the fin must be touched for some reason, first put on protective gloves and safety work clothing, and then proceed.

Do not climb onto or place objects on top of the outdoor unit. You may fall or the objects may fall off of the outdoor unit and result in injury.

When working at heights, use a ladder which complies with the ISO 14122 standard, and follow the procedure in the ladder’s instructions. Also wear a helmet for use in industry as protective gear to undertake the work.

When cleaning the filter or other parts of the outdoor unit, set the circuit breaker to OFF without fail, and place a “Work in progress” sign near the circuit breaker before proceeding with the work.

When working at heights, put a sign in place so that no-one will approach the work location, before proceeding with the work. Parts and other objects may fall from above, possibly injuring a person below.

The refrigerant used by this air conditioner is the R410A.

You shall ensure that the air conditioner is transported in stable condition.

Do not move or repair any unit by yourself. There is high voltage inside the unit. You may get electric shock when removing the cover and main unit.

Selection of installation location

If you install the unit in a small room, take appropriate measures to prevent the refrigerant from exceeding the limit concentration even if it leaks. Consult the dealer from whom you purchased the air conditioner when you implement the measures. Accumulation of highly concentrated refrigerant may cause an oxygen deficiency accident.

Do not install the air conditioner in a location that may be subject to a risk of exposure to a combustible gas. If a combustible gas leaks and becomes concentrated around the unit, a fire may occur.

When transporting the air conditioner, wear shoes with additional protective toe caps.

When transporting the air conditioner, do not take hold of the bands around the packing carton. You may injure yourself if the bands should break.

Install the indoor unit at least 2.5 m above the floor level since otherwise the users may injure themselves or receive electric shocks if they poke their fingers or other objects into the indoor unit while the air conditioner is running.

Do not place any combustion appliance in a place where it is directly exposed to the wind of air conditioner, otherwise it may cause imperfect combustion.

Installation

When the indoor unit is to be suspended, the designated hanging bolts (M10 or W3/8) and nuts (M10 or W3/8) must be used.

Install the air conditioner at enough strong places to withstand the weight of the unit. If the strength is not enough, the unit may fall down resulting in injury.

Follow the instructions in the Installation Manual to install the air conditioner. Failure to follow these instructions may cause the product to fall down or topple over or give rise to noise, vibration, water leakage, etc.

The designated bolts (M10, M12) and nuts (M10, M12) for securing the outdoor unit must be used when installing the unit.

Install the outdoor unit property in a location that is durable enough to support the weight of the outdoor unit. Insufficient durability may cause the outdoor unit to fall, which may result in injury.

5-EN

– 5 –

Image 6
Contents Installation Manual Contents Concealed Duct High Static Pressure Installation Manual Agent Qualifications and knowledge which the agent must haveWork undertaken Protective gear worn Burst Hazard Installation Precautions for SafetySelection of installation location GeneralExplanations given to user Electrical wiringTest run RelocationTo Disconnect the Appliance from Main Power Supply Accessory Parts Part name ’tyUsage Selection of Installation Place Installation under high-humidity atmosphereAvoid installing in the following places Installation example Installation spaceFilter cleaning sign term setting Unit mmInstallation External DimensionsInstallation of hanging bolt Installation of hanging boltInstallation of indoor unit Treatment of ceilingDiagrams for making connecting flanges Air inlet port connecting flangeAir outlet port flange Duct installation example First floor Duct designFAN Characteristics RAV-SM2242 TypeRAV-SM2802 Type Standard Middle static pressure F2 Wire connection change of fan motorLow static pressure F1 High static pressure F3Drain Piping Work Drain up Connecting drain pipePipe material, size and insulator Pipe materialCheck the draining Heat insulating process Pipe size Refrigerant Piping and EvacuatingRefrigerant Piping Liquid side refrigerant pipe connectionTightening connection Gas side refrigerant pipe connectionEvacuation Piping with outdoor unitGas leak check Refrigerant amount to be addedOpen the valve fully Heat insulation processRemote controller wiring Wiring diagramPower and Wiring Specification WiringWire connection Terminal block of electrical control boxRemote Controller Wiring Wiring diagramGroup control Basic procedure for changing settings Changing of setting applicable controlWhen power is turned on for the second or later time Applicable ControlsDetection temperature shift value Filter sign settingPower saving mode To secure better effect of heatingCode No Data name Remote controller switch monitoring functionOutdoor unit data Indoor unit dataGroup control Group control for system of multiple unitsProcedure example Manual address setup procedure33-EN 8C Operation 000010TEST RUN Before test runExecute a test run 11MAINTENANCE Daily maintenance Cleaning of air filterMaintenance List Part Unit Check visual/auditory Maintenance12TROUBLESHOOTING Confirmation of error logConfirmation and check Error codes and parts to be checked Status40-EN
Related manuals
Manual 110 pages 30.72 Kb

RAV-SM2242DT-E, RAV-SM2802DT-E specifications

Toshiba has long been a leader in heating, ventilation, and air conditioning (HVAC) technology, offering innovative solutions that cater to both residential and commercial needs. Among their impressive lineup, the Toshiba RAV-SM2802DT-E and RAV-SM2242DT-E stand out as exceptional models designed for efficiency, performance, and comfort.

The RAV-SM2802DT-E is a powerful unit ideal for larger spaces, boasting a cooling capacity of 28,000 BTU/h and a heating capacity of 31,000 BTU/h. This model features a highly efficient inverter compressor, which adjusts the power consumption based on the cooling or heating demand, ensuring optimal energy use. This inverter technology not only reduces energy consumption but also maintains a stable indoor temperature for enhanced comfort.

On the other hand, the RAV-SM2242DT-E is tailored for mid-sized applications with a cooling capacity of 22,000 BTU/h and a heating capacity of 25,000 BTU/h. This model also embraces inverter technology, promoting lower operational costs while delivering reliable performance. Both units come with a high energy efficiency rating, reducing environmental impact and saving on utility bills.

One of the key characteristics of these Toshiba models is their advanced filtration system. Equipped with a high-performance filtration mechanism, they can effectively reduce dust, allergens, and other pollutants, ensuring a healthier indoor environment. The units also operate quietly, contributing to a peaceful atmosphere, whether in a home, office, or commercial space.

Both the RAV-SM2802DT-E and RAV-SM2242DT-E are designed with user convenience in mind. They come with a user-friendly remote control, allowing for easy adjustments and settings from anywhere in the room. Compatibility with smart home systems further enhances user experience by enabling remote monitoring and control through smartphones or tablets.

Constructed with durability in mind, these units are built to withstand diverse weather conditions, making them suitable for various climatic environments. Additionally, their aesthetic design allows for seamless integration into any setting, ensuring that performance does not compromise on looks.

In summary, Toshiba's RAV-SM2802DT-E and RAV-SM2242DT-E offer a blend of superior technology, energy efficiency, and user-friendly features. With their inverter technology, advanced filtration systems, and durable designs, these models represent Toshiba's commitment to quality and innovation in the HVAC industry. Whether for residential or commercial applications, these units guarantee comfort and reliability all year round.