Toshiba RAS-13UKV-E2, RAS-13UAV-E2 How to Check Simply the Main Parts, Inspection procedures

Page 67

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FILE NO. SVM-03008

 

 

 

 

 

 

 

 

 

 

 

 

 

Diagnosis/Process flowchart

 

Item

 

Contents

 

Summary

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A

 

 

 

B

 

 

C

 

 

 

 

 

 

Check

Check winding resistance

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

between phases of

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

compressor, and resistance

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

between outdoor frames by

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Check

 

 

 

NG

 

 

using a tester.

OK if 10M

or more

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Is not grounded.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

winding of

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

compressor.

 

 

 

Is not short-circuited

}

OK if 0.51

0.57

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

between windings.

(Check by a digital tester.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Winding is not opened.

 

 

 

 

 

 

 

 

 

 

 

 

 

Check

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Replace

 

 

 

 

 

 

 

 

 

 

 

 

NG

fan motor

 

 

 

 

 

 

 

com-

 

Operation

Remove connector CN300 of

 

 

 

 

 

 

 

 

 

 

 

 

 

position

 

 

 

 

 

pressor.

 

 

the outdoor fan motor, turn on

 

 

 

 

 

 

 

 

 

 

 

 

 

detect

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

signal.

 

 

 

 

 

 

 

 

 

 

 

 

the power breaker, and

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OK

 

 

 

 

 

 

 

 

 

 

 

 

perform the operation. (Stops

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

though activation is

 

 

 

 

 

 

 

 

Replace

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

prompted.)

 

 

 

 

 

 

 

 

outdoor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Check operation within 2

 

 

 

 

 

 

 

 

 

fan

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

minutes 20 seconds after

 

 

 

 

 

 

 

 

motor.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

activation stopped.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

<Output check of fan motor

a) One or two of three

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Replace control

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

position detect signal>

 

voltages should be 5 V,

 

 

 

 

 

 

 

 

 

 

 

board assembly.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

While connecting connector

 

and others should be 0V.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5P (CN301) for position

 

(When all are 0V or 5 V,

 

 

 

 

 

Check

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

detection, using a tester,

 

it is not accepted.)

 

 

 

 

 

 

 

 

 

 

NG

 

 

 

 

 

 

 

 

 

 

 

 

measure voltage between

b) When rotating the fan

 

 

 

compressor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

winding

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1-5. Between 5-4 : 5 V

 

slowly with hands, the

 

 

 

resistance.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

voltage between pins

 

 

 

 

 

 

OK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

should move from 0V to 5 V.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Check it with an analog

 

 

 

 

Replace

 

 

 

 

 

 

 

 

 

Replace

 

 

 

 

 

tester.)

 

 

 

control board.

 

 

 

compressor.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10-8. How to Check Simply the Main Parts

10-8-1. How to check the P.C. board (Indoor unit)

(1)Operating precautions

1)When removing the front panel or the P.C. board, be sure to shut off the power supply breaker.

2)When removing the P.C. board, hold the edge of the P.C. board and do not apply force to the parts.

3)When connecting or disconnecting the connec- tors on the P.C. board, hold the whole housing. Do not pull at the lead wire.

(2)Inspection procedures

1)When a P.C. board is judged to be defective, check for disconnection, burning, or discolora- tion of the copper foil pattern or this P.C. board.

2)The P.C. board consists of the following 2 parts

a.Main P.C. board part:

DC power supply circuit (5 V, 12 V, 15 V), Indoor fan motor control circuit, CPU and peripheral circuits, buzzer, and Driving circuit of louver.

b.Indication unit of infrared ray receiving Infrared ray receiving circuit, LED:

To check defect of the P.C. board, follow the procedure described below.

– 66 –

Image 67
Contents AIR Conditioner Contents HOW to Replace the Main Parts Specifications SpecificationsCapacity Variation Ratio According to Temperature Operation Characteristic CurvePiping materials and joints used Safety During Installation/ServicingRefrigerant Piping Installation Refrigerant R410AProcessing of piping materials 1 Thicknesses of annealed copper pipesThickness mm Outer diameter mm R410A R22Diameter Flare tool for R410A Conventional flare toolClutch type Wing nut type Width·m kgf·m ·m kgf·cmRequired tools ToolsGeneral tools Conventional tools can be used Recharging of Refrigerant 1 Configuration of refrigerant chargingBrazing of Pipes Brazing Characteristics required for fluxTypes of flux Noncorrosive flux Activated flux215 Indoor UnitCover PV Outdoor Unit1 Simple Check for Failure Diagnosis Wiring DiagramCheck Item Diagnosis Result BRW Rating Specification of Electrical PartsSpecifications Parts nameRefrigerant Cycle Diagram Refrigerant Cycle DiagramOperation Data Rays Control Block DiagramMCC813P.C.B Outdoor Unit Inverter AssemblyOutlined of Air Conditioner Control Operation DescriptionRevolution rps Power factor improvement controlCapacity control 1 Compressor revolution range Operation ModelIndoor fan control DC fan motor Prevent-freezing control5. P.M.V. Pulse Modulating Valve Louver controlModel name Outdoor fan control DC fan motorCompressor revolution rps From Cooling capacity control Description of Operation CircuitBy indoor fan speed Limit for maximum compressor motor speedHeating operation Basic controlDefrost control Starting and in stability StabilityHeating capacity control High-temp. release controlTime Automatic operationTemporary cooling operation Temporary OperationTemporary button Control Temporary auto operationAuto Restart Function How to set auto restart functionWhen the unit is on standby Not operating Operation When the unit is in operation OperationFilter Check Lamp Remote Control and its Functions Hi-POWER display Mode displayTemperature display Timer and clock time displayFile NO. SVM-03008 Safety Cautions Installation ProcedureTo Disconnect the Appliance from the Main Power Supply File NO. SVM-03008 Attach Installation Diagram of Indoor and Outdoor UnitsFixing bolt arrangement of outdoor unit Optional installation parts Part Parts name ’ty CodeOption Accessory and installation partsOthers NameNew tools for R410A Applicable to R22 model Changes Cutting a hole Installation placeRemote controller Mounting the installation plateElectrical work When the installation plate is directly mounted on the wallDie-cutting Front panel slit How to remove the Drains CapChanging drain hose Case of bottom right or bottom left piping How to fix the Drains CapCase of right or left piping Left-hand connection with pipingDrainage Run the drain hose sloped downwards Indoor unit fixingCopper pipe Tightening connection Refrigerant piping connection FlaringProjection margin in flaring a Unit mm R410A Conventional Copper pipe Tool usedEvacuating Using a vacuum pumpOuter dia Tightening torque Copper pipe Shaping pipesWiring connection Packed valve handling precautionsStripping length of connection cable Test operation Auto restart settingHow to set the auto restart Gas leak testFirst Confirmation HOW to Diagnose the TroubleOperation which is not a trouble Program operation Primary JudgmentOperation of air conditioner Description Judgment by Flashing LED of Indoor Unit IndoorindicationHow to use remote control in service mode Self-Diagnosis by Remote Control Check CodeCause of operation Short circuit. Replace Check Item Judgment of Trouble by Every SymptomTurn on power supply YES Only indoor fan motor does not operate Primary checkInspection procedure Troubleshooting for remote control Pipe clogging Check procedure Check Code 1C Miswiring in indoor/outdoor units and 1EAGE on P.C. board How to Diagnose Trouble in Outdoor UnitMain P.C. board part How to Check Simply the Main PartsDiagnosis/Process flowchart Contents Summary Inspection proceduresOPERATION, TIMER, PRE. DEF Check procedures Procedure Check points Symptom Causes10-8-2. P.C. board layout Sensor characteristic tableBottom View Outdoor unit Part name Checking procedure Indoor unit Other parts Part name Checking procedureDiode check Igbt check Checking Method for Each Part Part name Checking procedureCause SymptomPart name Procedures Remarks HOW to Replace the Main PartsFigure below For position of the fan motor connector Microcomputer Detachment Requirement Connector is one Assembly to other parts Fan motor Perform work of item 1 of 1 Set take-out part of the lead wire of coil to Part name Board layout MCC-813 Indoor Unit E-Parts Assy Exploded Views and Parts ListFront Panel Assy Cabinet, Front, Assy Outdoor Unit E-Parts Assy Toshiba Carrier Corporation

RAS-13UAV-E2, RAS-13UKV-E2 specifications

The Toshiba RAS-13UKV-E2 and RAS-13UAV-E2 air conditioning units represent a significant step forward in both comfort and energy efficiency. Designed for residential and light commercial use, these models are packed with features that cater to diverse climate control needs while adhering to modern standards of sustainability.

One of the standout features of both models is the implementation of inverter technology. This advanced system allows for more precise temperature control by adjusting the compressor speed based on the ambient temperature requirements. This not only enhances energy efficiency but also ensures a quieter operation compared to traditional air conditioning systems. As a result, users benefit from consistent comfort without the disruptive sounds often associated with cooling units.

The RAS-13UKV-E2 and RAS-13UAV-E2 also feature a high energy efficiency rating, which is crucial for reducing electricity bills. The Seasonal Energy Efficiency Ratio (SEER) is a vital measure of energy efficiency over an entire cooling season. Both units excel in this regard, making them an environmentally friendly choice. This is further supported by Toshiba's commitment to incorporating R32 refrigerant, known for its lower environmental impact compared to older refrigerants.

User convenience is enhanced with integrated smart controls. Both models are compatible with wireless remote control features, allowing for easy adjustments from a distance. This is complemented by programmable settings that let users schedule operation times, ensuring that the units run only when needed, which further optimizes energy consumption.

Design-wise, these air conditioners boast a sleek and modern appearance, making them a visually appealing addition to any room. They are constructed with durable materials that ensure longevity and reliability. Moreover, the filters are designed for easy maintenance, ensuring cleaner indoor air quality and prolonging the lifespan of the unit.

The Toshiba RAS-13UKV-E2 and RAS-13UAV-E2 units also come equipped with advanced air purification technologies. These features help to reduce airborne pollutants and allergens, contributing to a healthier indoor environment. With exceptional cooling and heating capabilities, easy installation, and advanced features, these models are designed to meet the modern user's needs for comfort, efficiency, and health. Overall, they represent an excellent investment in both cooling technology and eco-friendly practices.