Roberts Gorden 350, 200, 150, 400, 250, 300, 225, 175 service manual Combat

Page 1

FOR YOUR SAFETY

If you smell gas:

1.Open windows.

2.DO NOT try to light any appliance.

3.DO NOT use electrical switches.

4.DO NOT use any telephone in your building.

5.Leave the building.

6.Immediately call your local gas supplier after leaving the building. Follow the gas supplier’s instructions.

7.If you cannot reach your gas supplier, call the Fire Department.

WARNING

Fire Hazard

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

Some objects will catch fire or explode when placed close to heater.

Failure to follow these instructions can result in death, injury or property damage.

WARNING

Improper installation, adjustment, alteration, service or maintenance can result in death, injury or property damage. Read the Installation, Operation and Service Manual thoroughly before installing or servicing this equipment.

Installation must be done by a contractor qualified in the installation and service of gas-fired heating equipment or your gas supplier.

Quality in Any Language™

© Copyright 2007 Roberts-Gordon, LLC

Combat®

UHA-Series

Tubular Unit Heaters

(Standard Range)

Installation, Operation

& Service Manual

Models UHA[S] 150, 175, 200, 225 250, 300, 350, 400

Installer

Please take the time to read and understand these instructions prior to any installation.

Installer must give a copy of this manual to the owner.

Owner

Keep this manual in a safe place in order to provide

your serviceman with necessary information.

Roberts-Gordon, LLC

1250 William Street

P.O. Box 44

Buffalo, New York 14240-0044

Telephone: 716.852.4400

Fax: 716.852.0854

Toll Free: 800.828.7450

www.rg-inc.com

P/N 111101NA 10/07 Rev. D

Image 1
Contents Combat Page Roberts-Gordon, LLC Page Table of Figures Page Manpower Requirements Heater SafetyWall Tag Installer ResponsibilityCorrosive Chemicals National Standards and Applicable CodesSeparated Combustion Installation Minimum Required Installation ClearancesCritical Considerations 3.1 Basic Information Clearances to CombustiblesInstallation Clearances and Clearances to Combustibles National Standards and Applicable Codes Suspension Major Components 5.1 GeneralVenting 6.1 Venting Vent InstallationUnited States Requirements Canadian RequirementsUnvented Operation Separated Combustion Heaters Models Uhas 150Horizontal Venting Vertical VentingVent and Roof Detail Vent MaterialStandard Vented Heater Common Vertical Vent Termination Concentric Vent Box Horizontal AIR Supply Unvented InstallationBuilding Ventilation Outside Combustion Air SupplyConnections GAS PipingPositioning Thermostats WiringFan Control Low Voltage Thermostat with One HeaterTransformer Uhas Series Internal Wiring DiagramUhas Series Ladder Wiring Diagram Electrical Connection to the Heater Louvers Operation and MaintenanceElectrical Checks Mechanical ChecksAutomatic Burner Control Sequence Check Gas Rate Pressure SwitchTurning Off the Heater Complete the Start-UpSimple Troubleshooting Burner Faults Simple TroubleshootingHeater Operation To Turn the Heater OffUser Instructions 12.3 Fan/Motor Assembly Maintenance Burner MaintenanceHeat Exchanger Maintenance Gas Valve MaintenanceInstallation Code and Annual Inspections All Maintenance ChecklistVicinity of the Heater Vehicles and OtherBurner Observation When installedWindow Combustion Fan ScrollTroubleshooting 13.1 General Result in death or electrical shock Troubleshooting For Automatic Ignition Burner SystemsStart Troubleshooting for Flame Supervision SystemTroubleshooting for Combustion Fan Troubleshooting for Gas ValvesConduct start-up procedure as shown on Page 19, Section Burner Components Replacement PartsBurner Injectors Burner CompartmentDescription Part Number Qty Ignition Electrode and Flame ProbeCombustion Fan Vertical Installation Uhas Limit Switches Removal and Replacement Axial Fan/Guard/Motor AssemblyFan Removal and Replacement To Replace the Fan AssemblyStandard Models 150 400 Uhas Series Dimension Data SpecificationsTechnical Data Table All Models General Technical Data Table All ModelsROBERTS-GORDON will PAY for Warranty is Void ifROBERTS-GORDON will not PAY for Limitations on Authority RepresentativesPage Page Some objects can catch fire or explode when placed
Related manuals
Manual 52 pages 19.42 Kb Manual 62 pages 5.65 Kb

175, 225, 300, 250, 400 specifications

Roberts Gorden is a recognized leader in the field of heating solutions, particularly renowned for the development of its innovative radiant heating systems. The lineup of models including the Roberts Gorden 250, 300, 400, 150, and 225 features a blend of advanced technology, exceptional efficiency, and versatile applications that cater to various industrial and commercial needs.

At the core of Roberts Gorden products is their radiant heating technology. Unlike conventional heating systems that warm the air, radiant heaters emit infrared radiation, which directly heats objects and people within a space. This method not only provides a comfortable environment but also reduces energy consumption and minimizes the loss of heat, making it an environmentally friendly choice.

The Roberts Gorden 250 model is specifically designed for smaller spaces, offering compact efficiency without sacrificing power. It features an adjustable output, allowing for tailored heating based on specific requirements. The advanced burner technology ensures optimum combustion efficiency, translating to cost savings on fuel consumption.

Moving on to the Roberts Gorden 300, this unit is well-suited for medium-sized facilities. With enhanced capabilities, the 300 model offers improved heating distribution, making it ideal for warehouses and production floors. The ease of installation and maintenance further enhances its appeal, allowing businesses to focus on their operations rather than on complicated heating systems.

The Roberts Gorden 400 is a powerhouse in the lineup, engineered for larger spaces that demand high-performance heating. Its robust construction and powerful output provide effective warmth even in challenging environments. The unit is equipped with sophisticated controls that promote energy efficiency while maintaining optimum comfort levels.

In the mid-range spectrum, the Roberts Gorden 150 and 225 models cater to businesses needing versatile heating solutions. Both models are designed with user-friendly interfaces and include safety features that comply with industry standards. Their lightweight design allows for easy installation and mobility, making them suitable for temporary or permanent heating applications.

Overall, Roberts Gorden's commitment to innovation and efficiency is evident across its product range. With a focus on sustainability and advanced heating technologies, the Roberts Gorden 250, 300, 400, 150, and 225 models provide reliable heating solutions that meet the diverse preferences of industrial and commercial users. These products are not just about warmth; they are about creating a comfortable and productive environment while minimizing energy costs and environmental impact.